Page 3 - SAFETY INSTRUCTIONS; ELECTRICAL SHOCK HAZARD; WARNING; Safety Instructions for the Operator; CAUTION
i SAFETY INSTRUCTIONS WARNING Immediately turn off the power at theswitchboard if water leaks into theequipment or something is dropped inthe equipment. Continued use of the equipment can causefire or electrical shock. Contact a FURUNOagent for service. Do not disassemble or modify theequipment. Fir...
Page 4 - ii; Safety Instructions for the Installer
ii Safety Instructions for the Installer WARNING Turn off the power at the switchboardbefore beginning the installation. Fire or electrical shock can result if thepower is left on. Do not install the equipment where itmay get wet from rain or water splash. Water in the equipment can result in fire,e...
Page 5 - iii; TABLE OF CONTENTS
iii TABLE OF CONTENTS FOREWORD ......................................................................................................... iv SYSTEM CONFIGURATION ................................................................................. v EQUIPMENT LIST ...........................................
Page 6 - iv; FOREWORD; A Word to the Owner of the IB-782; The main features are
iv FOREWORD A Word to the Owner of the IB-782 FURUNO Electric Company thanks you for purchasing the IB-782 Multi-Communication Unit. We are confident you will discover why the FURUNO name has become synonymous with quality and reliability. For over 50 years FURUNO Electric Company has enjoyed an env...
Page 7 - SYSTEM CONFIGURATION
v SYSTEM CONFIGURATION : Option COMMNUNICATION UNIT IB-282 ANTENNA UNIT IB-180 ANTENNA UNIT IB-182 MULTI-COMMUNICATION UNIT IB-782 JUNCTION BOX IB-313 TEL or FAX 100-200 VAC TEL or FAX Max. 8 units
Page 8 - EQUIPMENT LIST; Name Type
vi EQUIPMENT LIST Name Type Qty Remarks Multi-Communication Unit IB-782 Installation Materials — 1 set • Power cable (3 m) • Tapping screw ( Φ 4.5, 4 pcs.)
Page 9 - Equipment Overview; Front panel; Rear panel
1 1. OPERATION 1.1 Equipment Overview The [POW ER] switch is located on the rear panel. W hen the power is applied, the diagnostic test checks the equipment for proper operation, and the “Line LEDs” on the front panel light and go off in numerical order. After the diagnostic test is completed, only ...
Page 11 - Connections for intercom feature; Calling IB-782’s telephones; receiver and dial again.; Calling communication unit’s telephones; ] key and hang up the handset upon completion of the call.
3 1.4 Intercom The intercom function is available when two or more telephones are connected to the IB-782. It allows communication between the telephones of the IB-782 and the telephones/handset of the communication unit IB-282 and between the telephones of the IB-782. COMMUNICATION UNIT IB-282 ANTE...
Page 12 - Calling from communication unit’s telephone to IB-782’s telephone; Forwarding a Call; How to forward a call; Automatic Call Forwarding; Setting
4 Calling from communication unit’s telephone to IB-782’s telephone 1. Pick up the receiver and listen for the dial tone. 2. Dial [*], [3], [0], party’s extension number (1-8), [#]. 3. Talk with party. 4. Hang up the receiver upon completion of the call. 1.5 Forwarding a Call A call may be forwarded...
Page 14 - PBX Mode Settings
6 2. SETTINGS 2.1 PBX Mode Settings Set the PBX mode from handset connected to the communication unit of the FELCOM 82 to enable use of the IB-782. 1. Turn on the communication unit. 2. From the handset of the communication unit, press [FUNC Quit], [5], [9], [8] to display the OID/OID menu. 5 9 O I ...
Page 16 - DIP Switch Setting; Changing Number for Connection to Inmarsat
8 2.3 DIP Switch Setting SW No. Function Default Setting ON OFF 1 How to connect to Inmarsat services OFF Connect with OFF HOOK. Connect by dialing 0 or 9. 2 — ON Fixed at “ON.” — 3 Receive only OFF YES NO 4 — OFF — Fixed at “OFF.” 2.4 Changing Number for Connection to Inmarsat Services The number f...
Page 18 - Mounting considerations; Locate the unit away from areas subject to rain and water splash.; Mounting procedure
10 4. INSTALLATION 4.1 Mounting Mounting considerations The IB-782 can be mounted on a desk or on a bulkhead. Keep the following points in mind when selecting a mounting location: • Leave sufficient space around the unit for maintenance and servicing. • Locate the unit away from direct sunlight beca...
Page 19 - Follow the illustration below to wire the IB-782.; Wiring
11 4.2 Wiring Follow the illustration below to wire the IB-782. 1 A P O W E R 1 0 0 V- 2 2 0 VAC 5 0 - 6 0 H z Telephone Facsimile Ground Terminal MULTI-COMMUNICATION UNIT IB-782 100-220 VAC Telephone Facsimile Junction Box IB-313 To Telephone(or FAX) LN8-LN1 LN0 TEL3 5 Rosette MJ-2S To Telephone(or...
Page 20 - SPECIFICATIONS OF THE MULTI-COMMUNICATION UNIT
SP - 1 8/8/01 SPECIFICATIONS OF THE MULTI-COMMUNICATION UNIT IB-782 1. GENERAL (1) Outside line 1 (2) Extension line 8 (3) Dialing Method NTT PB signal 2. POWER SUPPLY (1) Main Unit 100-220 VAC, 1 phase, 50-60 Hz, 20 VA (2) Power Consumption 10 W or less 3. ENVIRONMENTAL CONDITION (1) Ambient Temper...