Page 3 - SAFETY INSTRUCTIONS; WARNING; CAUTION
i SAFETY INSTRUCTIONS WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnelshould work inside theequipment. Immediately turn off the power at theswitchboard if water leaks into theequipment or an object is dropped intothe equipment. Continued use of the equipment can ca...
Page 4 - ii; RECORD OF MODIFICATIONS IN THIS OPERATOR’S MANUAL; Outline of changes in; Publicized for submission to type
ii WARNING LABELA warning label is attached to the Distributor, Transceiver and TerminalBox. Do not remove the labels. If alabel is missing or is illegible, contacta FURUNO dealer or agent aboutreplacement. WARNING To avoid electrical shock, do not remove cover. No user-serviceable parts inside. Nam...
Page 5 - iii; TABLE OF CONTENTS
iii TABLE OF CONTENTS SPECIFICATIONS ....................... SP-1 FOREWORD...................................... 1 SYSTEM CONFIGURATION ............. 2 PRINCIPLE OF OPERATION............ 3 REMARKS ON USAGE..................... 4 1 OPERATION OF DISPLAY UNIT . 5 1.1 Controls..............................
Page 7 - SPECIFICATIONS OF THE DOPPLER SPEED LOG
SP - 1 SPECIFICATIONS OF THE DOPPLER SPEED LOG DS-80 1. GENERAL (1) Speed Range Fore-Aft: -10.0 to +40 knots through-the-water (2) Distance Run 0.00 to 999,999.99 nautical miles through-the-water (3) Working Depth Water depth greater than 3 m beneath the keel. (4) Working Frequency 1.0 MHz (5) Speed...
Page 8 - SAFETY PRECAUTION; - There is no harmful radiation from the screen.
SP - 2 4. POWER SUPPLY (1) System Source 100/110/115/200/220/230 VAC:1.5/0.7 A max., 1 phase, 50-60 Hz 5. ENVIRONMENTAL CONDITION (IEC 60945) (1) Ambient Temperature -15°C to +55°C (units for protected area) Analog display: 0°C to +50°C (2) Relative Humidity 95% at 40°C (3) Vibration IEC 60945 adopt...
Page 9 - FOREWORD; Foreword
1 FOREWORD Foreword Thank you for purchasing the FURUNO DS-80 Doppler Speed Log. We are confident you will discover why FURUNO has become synonymous with quality and reliability. Dedicated in the design and manufacture of marine electronics equipment for half a century, FURUNO Electric Company has g...
Page 10 - SYSTEM CONFIGURATION; TRANSDUCER; DISTRIBUTION BOX
2 SYSTEM CONFIGURATION TRANSDUCER DS-820 DISPLAY UNITDS-800 IEC 61162-1 Input Power ON SW SignalDistance Run SignalIEC 61162-1 Output DIGITAL INDICATOR DS-830 DISTANCE INDICATOR DS-840 : STANDARD SUPPLY : OPTIONAL SUPPLY DISTRIBUTION BOX DS-801 TRANSCEIVER UNIT DS-810 DIMMER MF-22L-1/MF-22L-2 TERMIN...
Page 11 - PRINCIPLE OF OPERATION; calculate ship’s speed, the following formula
3 PRINCIPLE OF OPERATION The Doppler speed log measures ship's speed by using the Doppler Effect, which is observed as a frequency shift resulting from relative motion between a transmitter and receiver or reflector of acoustic or electro- magnetic energy. A common example of the Doppler Effect is a...
Page 12 - REMARKS ON USAGE; Remarks on Usage
4 REMARKS ON USAGE Remarks on Usage The DS-80 measures ship’s speed by detecting the Doppler shift frequency of the echo reflected by a watermass (water layer containing plankton and other micro- organisms) located within the measuring area, which is usually about 2 m. In some instances, however, no...
Page 13 - OPERATION OF DISPLAY UNIT; Controls; Turning the Power On/Off; The example below shows the speed and; Keep the DS-80 energized
5 1 OPERATION OF DISPLAY UNIT 1.1 Controls Opens/closes the menu. Selects display; speed plus distance or speed. Turns power on/off. Adjusts LCD contrast. Adjusts panel illumination. Registers options on menus. OmnipadSelects items, optionson menus. MENU PWR ENT DISP DIM * DS-80 1.2 Turning the Powe...
Page 15 - Main Menu Operation; To enter numerical data; Distance Run Operation
7 1.5 Main Menu Operation Functions of the DS-80 are selected through the menu. 1. Press the [MENU] key to open the menu. MENU DISTANCE RUN DISPLAY DEMOSYSTEM MENUSYSTEM MENU2 2. Press the Omnipad at or to select a menu item (current selection is highlighted) and press the [ENT] key. For example, wh...
Page 17 - System Setting
9 5. Press the [ENT] key to finish and press the [MENU] key twice to close the menu. The distance run indication reads 0.00. 1.7 System Setting The system setting provides the fundamental parameters for intended performance of the DS-80. 1.7.1 Displaying the system menu 1. Press the [MENU] key to op...
Page 19 - Demonstration Mode
11 1.7.7 System menu 2 The System Menu 2 contains the diagnostic test and selection of dimmer control and display language. 1. Press the [MENU] key to open the menu. 2. Select SYSTEM MENU 2 and press the [ENT] key. SYSTEM MENU2 TEST DIMMER INTERNAL /LANG. ENGLISH ENT: SET TEST: Checks the equipment ...
Page 20 - nm; DISTANCE RUN DISPLAY:; contrast
12 2 OPERATION OF OPTIONAL EQUIPMENT The Digital Indicator DS-830 and Distance Indicator DS-840 have the same controls as the display unit. This chapter explains the features which are not shared with the display unit. 2.1 Digital Indicator DS-830, Distance Indicator DS-840 2.1.1 Selecting a display...
Page 21 - Doppler Speed Log DS-80
13 ANALOG DISPLAY UNIT CORRECTION DIAGRAM AT EXTREME TEMPERATURES Doppler Speed Log DS-80 CORRECTION FACTOR FOR ANALOG DISPLAY MF-22A-1 Example: If the analog speedometer reads 14.2 kt at a temperature of –15 ° C, the correct speed through the water is 15 kt. Failure of correction in low temperature...
Page 22 - MAINTENANCE, TROUBLESHOOTING; Do not paint the transducer.; Unit
14 3 MAINTENANCE, TROUBLESHOOTING WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnelshould work inside theequipment. 3.1 Maintenance 3.1.1 Preventive maintenance Check the following points regularly to maintain performance. • Check that the connectors on all units of...
Page 23 - be done by referring to the Service Manual (optional supply).; Loosened power cable; Temperature sensor is abnormal.; If any abnormal speed indication continues
15 3.2 Troubleshooting This section provides troubleshooting procedures. Advanced level troubleshooting should be done by referring to the Service Manual (optional supply). Problem Probable cause Remedy General Loosened power cable Fasten the power cable. Cannot turn on the power. Blown fuse Replace...
Page 24 - Control operated and indication; UP
16 3.3 Diagnostics, Checking Program Number The diagnostic facility checks the ROM, RAM, SIO and displays program ID. 1. Press the [MENU] key to open the menu. 2. Select SYSTEM MENU2 and press the [ENT] key. SYSTEM MENU2 TEST DIMMER INTERNAL /LANG. ENGLISH 3. Press the [ENT] key. The following displ...
Page 25 - Sentences; Input sentences of IEC61162_RX port; s for VBW 1 s for VLW; Data transmission
17 4 DIGITAL INTERFACE (IEC 61162-1 Edition 2) 4.1 I/O Sentences Input sentences of IEC61162_RX port GGA, VTG Output sentences of IEC61162_TX1, IEC61162_TX2 ports VBW, VLW (Talker: VD) Transmission interval 3 s for VBW; 1 s for VLW Data transmission Data is transmitted in serial asynchronous form in...
Page 26 - Schematic diagrams; Load requirements as listener
18 Schematic diagrams IEC61162 RX port DS-801 65P6010 11 12 .... .. TB3 F2047A-20P-B IEC61162_RX_AIEC61162_RX_B <11< <12< JP6ERJ_6GEY0R00V R121 22 Ω R122 120 Ω R123 120 Ω R124 22 Ω 1 2 CR17 1SS181 4 5 6 1 3 JP7ERJ_6GEY0R00V PC400U42 Load requirements as listener Isolation: Optocoupler In...
Page 27 - Output drive capability
19 IEC61162 TX2 port DS-801 65P6010 10 9 .... .... TB3F2047A-20P-B IEC61162_TX2_AIEC61162_TX2_B <7<<8< R136 47 R135 47 87 U43SN75ALS191PS 2 Vcc 1 4 Output drive capability Max. 20 mA
Page 28 - Description; Time, position and fix related data for a GPS receiver.
20 4.2 Sentence Description GGA - Global positioning system (GPS) fix data Time, position and fix related data for a GPS receiver. Note: Item Only GPS quality indicator and antenna altitude above/below are used.
Page 29 - VTG - Course over ground and ground speed; The actual course and speed relative to the ground.
21 VTG - Course over ground and ground speed The actual course and speed relative to the ground. $--VTG,x.x,T,x.x,M,x.x,N,x.x,K,a*hh<CR><LF> | | | | | | | | | | | | | | | | | | | +------- 6 | | | | | | | | +--------- 5 | | | | | | +--+----------- 4 | | | | +--+----------------- 3 | | +--...
Page 30 - Notes; VLW - Distance travelled through the water; The distance travelled, relative to the water.
22 VBW - Dual ground/water speed Water-referenced and ground-referenced speed data. $--VBW,x.x,x.x,A,x.x,x.x,A,x.x,A,x.x,A*hh<CR><LF> | | | | | | | | | | | | | | | | | | | | | +--- 11 | | | | | | | | | +----- 10 | | | | | | | | +-------- 9 | | | | | | | +----------- 8 | | | | | | +------...
Page 31 - PARTS LOCATION AND PARTS LIST; Parts Location; Distribution box DS-801
23 5 PARTS LOCATION AND PARTS LIST Parts Location Display unit DS-800 U10 (ROM) ICP Board 65P6000, parts side Distribution box DS-801 From right TB1, TB2, TB3 JPW Board POWERswitch TB101 Distribution Box DS-801, inside view
Page 32 - Transceiver unit DS-810
24 Transceiver unit DS-810 KCP Board POWERSwitch TB101 TB1 Transceiver Unit DS-810, inside view
Page 33 - Parts List; can be located on parts location photos on the preceding page.
25 Parts List This equipment contains complex modules in which fault diagnosis and repair down to component level are not practicable (IMO A.694(17)/8.3.1). Only some discrete components are used. FURUNO ELECTRIC CO., LTD. believes identifying these components is of no use for shipborne maintenance;...
Page 34 - ELECTRICAL PARTS LIST
26 Model DS-80 Unit DISPLAY UNIT DS-800 ELECTRICAL PARTS LIST Ref.Dwg. C3441-K01-C 2000-01 Block.No. SYMBOL TYPE CODE No. REMARKS SHIPPABLEASSEMBLY PRINTED CIRCUIT BOARD 65P6000, ICP 000-142-649 X CABLE w/CONNECTOR MJ-A7SPF-005-020 000-139-384 20S0251 MJ-A6SPF-003-020 000-142-658 65S1231 MJ-PH 6P 00...
Page 37 - CALIBRATION SHEET
29 CALIBRATION SHEET CALIBRA TION SHEET FOR DS-80 DOPPLER SPEED LOG D A TE: TEST SITE SHIP'S LENGTH (M) DRAFT F ore Aft Mean (m) SHIP'S NAME Ser . No . DOCKY ARD TRIM (m) . DS-80 Location of T ransducer (m) from bo w or fr ame No . SEA ST A T E
Page 38 - MENU OVERVIEW; Default settings in bold italic.
30 MENU OVERVIEW Default settings in bold italic. [MENU] key DISTANCE RUN DISPLAY DATA DISPLAY ( CONTACT CLOSURE , IEC 61162-1(VLW)) RESET (ON, OFF ) SET (0.0 nm-999999.99 nm, 0.00 nm ) DEMO SYSTEM MENU SHIP SPD AVG (15, 30 , 45, 60 SEC) SPEED OFFSET (-25.0% to +25.0%, 0% ) TRACK DEPTH (1.0 m to 9.9...
Page 39 - INDEX
Index-1 INDEX C Contrast .......................................................... 6 Control description ......................................... 5 D Demonstration mode ...................................... 9 Diagnostics ................................................... 14 Digital indicator ......