Page 2 - Safety precautions
04 Safety precautions DANGER! Avoid Serious Injuryor Death 1. Do not attempt to install the split air conditioner by yourself. 2. This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs. 3. When moving the air conditioner, always call an aut...
Page 4 - from air
operation. It may cause electric removed, do not touch the metal parts of the unit. It may cause an injury. Safety precautions shock or injury. and electric shock. It may cause failure of appliance 11.Do not open the unit during 13.Do not disassemble or modify unit. 14.When the air filter is to be s...
Page 5 - Choosing the installation site; Installation Warnings
07 8. The site must allow for the easy removal of the connector pipe and drain hose. 9. The unit must be installed at a site protected from direct sunlight. Precautions for Installation Installation at the following sites may cause problems. If you must inevitably install 2. Sites with a high concen...
Page 6 - Outdoor Unit
Outdoor Unit 1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. There must not be the possibility of increased nois...
Page 7 - Parts list
Parts list 2 5 4 3 1 Indoor unit Outdoor unit Parts list Installation plate Clip anchor Seal Drain Joint . 1 2 3 4 5 1 2 1 1 10 8 1 1 Remote controller Remote Controller holder Connectingpipeassembly Liquid side Gas side NUMBER PART NAME QTY (capacity < 12000 Btu's) (capacity < 12000 Btu's) (c...
Page 8 - Attention; This illustration is for explanation purposes only.; Copper tubes must be insulated independently
Attention 1. This illustration is for explanation purposes only. 5 4 2 3 1 Indoor unit Outdoor unit 6 Air filter More A B C Parts list 2. Copper tubes must be insulated independently More than 5" More than 6" More than 5" 8 9 10 6 7 More than 2 feet than 2 feet More than 6.6 feet More th...
Page 10 - Fixing the Installation Plate; Wall; Indoor unit installation
Attention Fixing the Installation Plate Drilling the Hole 1. Install the installation plate horizontally over the structural parts on the wall using the spaces indicated on the plate, as shown 2. In the case of tiled, concrete or diameter holes. Place anchorage supports for the appropriate assembly ...
Page 11 - Pass the piping through the hole in
Connective pipe and drainage installation Drainage 1. Run the drain hose sloping downward. Do not install the drain 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack. Connective pipe 1. For the left-hand ...
Page 12 - Piping and wrapping; piped out of room, do not put; at the upper side may cause drain pan to overflow inside the unit.
Attention Piping and wrapping 1. Bundle the tubing, connecting cable, and drain hose with tape 2. Because the condensed water from rear of the indoor unit is gathered in ponding box and is anything else in the box. 1. Connect the indoor unit first, then the outdoor unit.2. Do not allow the piping to...
Page 13 - Outdoor unit installation
1. Install the outdoor part of the unit on a rigid surface to avoid excess noise and vibration. 2. Direct the air vent toward an area without obstacles. especially in areas where it is frequently windy. 4. If the installation site is exposed to heavy winds, such as in coastal areas, place the unit a...
Page 14 - Drain joint installation
Settlement of outdoor unit Anchor the outdoor unit tightly and horizontally on a concrete or rigid Fit the seal into the drain elbow, then insert the drain joint into the base pan hole of outdoor unit, rotate 90 o to securely assemble them. Connect the drain joint with an extension drain hose (Local...
Page 15 - Flaring work; Refrigerant piping connection
Flaring work Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct flaring work using the following procedure: 1. Cut the pipes and the cable.A) Use the piping kit accessory or pipes purchased locally. B) Measure the distance between the indoor and the outdoor un...
Page 16 - Connection Adjustment; Excessive twisting may; Screw the flare nut with your; Firmly hold copper pipe in a
4. Flaring work. die in the dimension shown in the table below. OUTER Connection Adjustment 1. Align the pipes to be connected. OUTER TIGHTENING Caution: Excessive twisting may break the nut, depending on the installation conditions. Refrigerant piping connection Bar pipe Handle Clamphandle Yoke Red...
Page 18 - Electrical work; designation 16AWG or heavier; CABLE
1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening ...
Page 19 - COOLING MODEL; HEATING AND COOLING MODE
Electrical work COOLING MODEL HEATING AND COOLING MODE HEATING AND COOLING MODEL 1 2(N) 3 4 1 2(N) 3 4 or Terminal block of indoor unit Terminal block of indoor unit Terminal block of indoor unit or "Connector A" "Connector A" "Connector B" To outdoor unit To outdoor unit To ...
Page 20 - Connect the cable to the outdoor unit
1. Remove the electrical control board cover from the outdoor unit by loosening the screw. 2. Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. The connective cable to power supply shal l be approved ...
Page 21 - HEATING AND COOLING MODEL
Electrical work COOLING MODEL HEATING AND COOLING MODEL HEATING AND COOLING MODEL or o or or "Conector A" "Conector A" "Conector C” "Conector B" "Conector B" "Conector D” Cablesboard Cablesboard Cablesboard Cablesboard Cablesboard Cablesboard 4 1 3 2(N) 4 1 3 ...
Page 22 - Caution; Air purging; Electrical work and air purging; to
1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check ...
Page 23 - Caution in handling the packed valve integrated in the outlets of
Air purging with vacuum pump 1. Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note tha...
Page 24 - When using the vacuum pump
Air purging Vacuum pump Charge hose Manifold valve -76cm/Hg Chargehose Handle Lo Handle Hi Outdoor unit Indoor unit When using the vacuum pump For method of using a manifold valve, refer to its operation manual. manifold valve. evacuate. After starting evacuation, slightly loose the flare nut of the...
Page 25 - Electrical safety; ty; Gas leak check; Soap water method; ic; Electrical safety and gas leak check
Electrical safety Perform the electric safe ty check after completing installation: Gas leak check Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of th e piping...
Page 26 - cannot be controlled by the remote controller to run; Test running; Auto; When the ambient temperature is too low(lower than 63
Test running Perform test operation after completing gas leak check at the flare nutconnections and electrical safety check. 1. Connect the power, press the ON/OFF button on the remote controller to turn the unit on. cannot be controlled by the remote controller to run in cooling mode, manual operat...
Page 27 - Preparing the device for operation; MODE
1. Contact a specialist to install the device.2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms.3. Before operating the air conditioner, ensure that the air filter is installed correctly.4. If the unit has been out of use for a long period ...