Page 2 - Contents
1 Contents Page Introduction 2 Model Details 2 QC 11 & QC 600 BQCF 40 Blast Chill Operating Instructions 3 Controller operating instructions 4 LED’s and there meanings 4 Program function and operation. 5 Cycle Parameter Definitions. 5 Cycle Parameter Access 5 QC 11 Cycle Parameters. 5 to 6 QC 60...
Page 3 - Cook Chill Operation; maintaining the texture, consistency and appearance of food; Longer Term Storage – ‘Hold’ Mode (Conservation)
2 Introduction. Cook Chill Operation . Blast chilling is a process to reduce the temperature of cooked food by swiftly arresting the cooking process,locking in its colour, flavour, texture and nutritional value. Department of health guidelines state that to safely blastchill food the temperature mus...
Page 4 - IMPORTANT; Hard Chill
3 QC 11, QC 600 & BQCF 40 Blast Chill Operating Instructions. Operation When mains electrical power is first applied to the controller it will carry out a self-test function - - - for approximately 3 seconds, after this the cabinet air temperature will be displayed.To start, select the program r...
Page 5 - Controller operating instructions; DOWN
4 Controller operating instructions Display Set Point : Press the SET key whilst in the HOLD Mode will display the set point for 5 seconds. Modify Set Point : Press and hold the SET key for 2 seconds. The SET point will be displayed and the LED’sof the first and third digits will blink. To change th...
Page 6 - for the safe chilling of delicate products
5 5 Illuminated When in program Pr2 indicates the parameter is also present in Program function and operation. Each of the programs is divided into 3 phases of operation . Phase 1: Hard Chill. Phase 2: Soft Chill. Phase 3: Freezing Cycle. For each phase there are 3 parameters. IS1 (iS2, iS3): operat...
Page 8 - QC 60 Cycle Parameters.; BQCF 40 Cycle Parameters.
7 Hard Chill Time - For general purpose chilling based on time. (Cy2) dbC = no iS1 = -15°C iS2 = 2°C iS3 = -18°C dbH = no rS1 = -15°C rS2 = 2°C rS3 = -30°C HdS = 3°C Pd1 = 1.1hours Pd2 = 0.2 hours Pd3= OFF Hard Chill +- . This program is for specialist chilling only and is not recommended for normal...
Page 9 - Hard Chill Temperature -; Function Menu
8 Hard Chill +- . This program is for specialist chilling only and is not recommended for normal use. (Cy3) dbC = no iS1 = - 6°C iS2 = 3°C iS3 = - 18°C dbH = no rS1 = - 15°C rS2 = 2°C rS3 = -30°C HdS = 3°C Pd1 = 1.1 hours Pd2 = 0.2 Pd3 = OFF Hard Chill Temperature - For general purpose chilling usin...
Page 10 - Regulation
9 PrP: Printer presence. (Yes or no) Enables or disables the printer. ItP: Printing interval. (0.0 to 30.0). Sets the print interval. PbP: Print probe selection. ( iP: only the food probe selected. rP: only the air probe selected. irP: Food and Air probe selected. irE: All probes selected). PtH: (ye...
Page 11 - Parameter Definitions
10 Alarm ALU MAXIMUM temperature alarm 30 30 30 30 ALL Minimum temperature alarm 30 30 30 30 ALd Temperature alarm delay 60 60 60 60 EdA Alarm delay after defrost 30 30 30 30 tbA Silencing alarm relay YES YES YES YES Others Ad1 Address 1 for RS485: 0 0 0 0 Ad2 Address 2 for RS485 1 1 1 1 Lod Local d...
Page 15 - QC 11 Wiring Diagram
Page 16 - QC 600 Wiring Diagram
Page 17 - BQCF 40 Wiring Diagram. Sheet 1 of 2
Page 18 - BQCF 40 Wiring Diagram. Sheet2 of 2
Page 19 - Foster European Operations
Foster European Operations FranceFoster Refrigerator France SATel: (33) 01 34 30 22 22. Fax: (33) 01 30 37 68 74. Email: [email protected] GermanyFoster Refrigerator Gmbh,Tel: (49) 2333 839375. Fax (49) 2333 839377.Email: [email protected] Foster Refrigerator Oldmedow RoadKings LynnNorfo...