Page 3 - Technical Specification.
2 Introduction The display case are manufactured in two formats FHG 2L, 2 doors, and the FHG 3L, three doors.There are also Multiplex options that are a combination of two FHG 2L cases to make a FHG 4L or a combinationof the FHG 2L and FHG 3L to make a FHG 5L. Technical Specification. Model 2 Door 3...
Page 4 - Temperature controller; Controller Display and Symbols.; Mutes the audible alarm and deactivates the alarm relay.
3 Temperature controller It is strongly advised that before adjusting any Service Parameters a thorough understanding of thefollowing instructions should be obtained. Carel PB00F0HB10 Controller Display and Symbols. NOTE: When the buttons are pressed a brief audible signal is emitted; this signal ca...
Page 5 - Accessing the type “F” parameters.
4 9. Compressor: Illuminated when the compressor is running. Flashes when the activation of the compressor is delayed by safety times. 10. FAN: Illuminated when the fan starts. Flashes when the activation of the fan is prevented due to external disabling or procedures in progress. 11. DEFROST: Illum...
Page 7 - RTC
6 Classification of Parameters The parameters, as well as being divided into type, are also grouped into logical categories identified by the initialletters or symbols of such parameters. The following table lists the categorise and the corresponding letters. Parameter Category Text Icon / Temperatu...
Page 9 - Parameter Definitions; Sets the rate at which the temperature display is updated.
8 Parameter Definitions /2 Measurement stability. Defines the coefficient used to stabilise the temperature reading. /3 Probe display rate Sets the rate at which the temperature display is updated. /4 Probe average (Virtual probe) Used to choose whether to control the temperature based solely on the...
Page 14 - Spare Parts List
13 Default: H3 = 0. H4 Disable buzzer. H4 = 0 buzzer enabled. H4 = 1 buzzer disabled.Default: H4 = 0. H5 Function of relay 5 . Not used by Foster.Default: H5 = 3. H6 Lock out Buttons. Not used by Foster.Default: H6 = 0. H7 Select Keypad. Used to select the type of keypad on the controller.Default: H...
Page 15 - MCB; Wiring diagrams; The drawings numbers for the display cases are as follows:
14 MCB Siemens 5SY6316 –8 TP 16 Amp 3 Pole 16240209 X X Wiring diagrams The drawings numbers for the display cases are as follows: FHG2L - 2 door unit single phase 00-233867-02 FHG2L - 2 door unit three phase 00-233868-02 FHG3L - 3 door unit three phase 00-233869-02
Page 17 - FHG2L - 2 door unit single phase
Page 18 - FHG2L - 2 door unit three phase
Page 19 - FHG3L - 3 door unit three phase
Page 20 - Foster European Operations
Foster European Operations FranceFoster Refrigerator France SATel: (33) 01 34 30 22 22. Fax: (33) 01 30 37 68 74. Email: [email protected] GermanyFoster Refrigerator Gmbh,Tel: (49) 2333 839375. Fax (49) 2333 839377.Email: [email protected] Foster Refrigerator Oldmedow RoadKings LynnNorfo...