Page 2 - DANGER: Carbon monoxide; WARNINGS; WARNING: Any change to this
2 105224 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED SAFETYINFORMATION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re-semble the flu, with headaches, dizziness,or nausea. If you have these signs,...
Page 3 - OWNER’S MANUAL; LOCAL CODES; OPERATION; UNPACKING; CAUTION: Do not remove the; Figure 1 - Product Identification; Control Knob
3 105224 OWNER’S MANUAL AUT O MAN OFF ST ATUS ON LO HI TEMP PRODUCTIDENTIFICATION LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANS Z223.1, also known as NFPA 54*. *Available from: American Natio...
Page 4 - Unusually Tight Construction; kg; Confined and Unconfined Space; per
4 105224 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED PROVIDING ADEQUATEVENTILATION The following are excerpts from NationalFuel Gas Code. NFPA 54/ANS Z223.1, Sec-tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the threefollowing ventilat...
Page 5 - DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space; Continued
5 105224 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless ...
Page 6 - VENTILATION AIR; Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings for; Figure 2 - Ventilation Air from Inside Building
6 105224 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED AIR FORCOMBUSTION ANDVENTILATION Continued VENTILATION AIR Ventilation Air From InsideB u i l d i n g This fresh air would come from an adjoiningunconfined space. When ventilating to anadjoining unconfined space, you mu...
Page 7 - LOG SIZING REQUIREMENTS; MINIMUM FIREPLACE; B. Clearances from the top of the fireplace; INSTALLATION; CHECK GAS TYPE
7 105224 OWNER’S MANUAL LOG SIZING REQUIREMENTS L o g Minimum Firebox Size Height Depth W i d t h 27" 17" 19" 32" INSTALLATION ANDCLEARANCES(Vent-Free Operation Only) Figure 4 - Minimum Clearance to Wall andCeiling WARNING: Maintain the mini- mum clearances. If you can, pro-v i d e g...
Page 8 - If using a mantel, proceed to; If Using; Installing Damper; If you cannot meet these
8 105224 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED INSTALLATION Continued Minimum NoncombustibleMaterial Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel . If not using a mantel, follow the information below. You must have noncombustibl...
Page 9 - Figure 7 - Minimum Mantel Clearances When Using Hood; Figure 6 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; Hearth; FLOOR CLEARANCES; A. If installing appliance on the floor level,; flue damper open
9 105224 OWNER’S MANUAL Figure 7 - Minimum Mantel Clearances When Using Hood INSTALLATION Continued Figure 6 - Minimum Mantel Clearances Without Using Hood MANTEL CLEARANCES In addition to meeting noncombustible ma-terial clearances, you must also meet re-quired clearances between fireplace open-ing...
Page 10 - Installation Items Needed; or masonry as applicable); You prefer vented operation.; Chimney; Area of Various Standard; Figure 10 - Attaching Damper Clamp; Damper; Manufactured Fireplace
10 105224 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED INSTALLATION Continued INSTALLING HEATER BASEASSEMBLY Installation Items Needed • hardware package (provided with heater)• approved flexible gas hose (not provided) (if allowed by local codes) • sealant (resistant to p...
Page 11 - C A U T I O N : N e v e r c o n n e c t; • external regulator (supplied by installer,; WARNING: Never connect; Figure 14 - Gas Connection; Attach base assembly to fireplace floor
11 105224 OWNER’S MANUAL CONNECTING TO GASSUPPLY WARNING: A qualified ser- vice person must connect heaterto gas supply. Follow all localcodes. C A U T I O N : N e v e r c o n n e c t heater directly to the propane/LPsupply. This heater requires anexternal regulator (not supplied).Install the extern...
Page 12 - Figure 15 - Manual Shutoff Valve; Open; Figure 16 - Checking Gas Joints; Test Pressures In Excess Of 1/2 PSIG; Correct all leaks at once.
12 105224 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED ON POSITION OFF POSITION Figure 15 - Manual Shutoff Valve Open Closed ManualShutoffValve Figure 16 - Checking Gas Joints Pressure Testing Gas SupplyPiping System Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heate...
Page 13 - INSTALLING LOGS; Make sure log; CAUTION: After installation
13 105224 OWNER’S MANUAL O FF P IL OT O N H I L O INSTALLATION Continued WARNING: Failure to posi- tion the parts in accordance withthese diagrams or failure to useonly parts specifically approvedwith this heater may result in prop-erty damage or personal injury. INSTALLING LOGS It is very important...
Page 14 - FOR YOUR SAFETY; • If fireplace has glass doors,
14 105224 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED O F F PIL O T O N L O I H AUTO OFF ON 1. STOP! Read the safety information,column 1. 2. Make sure manual shutoff valve isfully open. 3. Set switch in OFF position. OPERATINGHEATER FOR YOUR SAFETY READ BEFORE LIGHTING W...
Page 15 - Pilot Burner; CAUTION: Do not try to adjust; Shutting Off Heater; All remote control accessories must
15 105224 OWNER’S MANUAL Figure 22 - Pilot IgnitorElectrode Pilot Burner 8. Keep control knob pressed in for 30seconds after lighting pilot. After 30seconds, release control knob.• If control knob does not pop out when released, contact a qualifiedservice person or gas supplier forrepairs. Note: If ...
Page 16 - This remote control; Figure 25 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to; BURNER PRIMARY AIR HOLES; To turn the pilot off,
16 105224 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED IMPORTANT: This remote control has been specially engineered to takean air temperature sample every 5.5minutes in the auto mode. It will notrespond immediately to the tempera-ture setting being turned up or down. I M P...
Page 17 - TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in
17 105224 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing.Only a qualified service persons h o u l d s e r v i c e a n d r e p a i rheater. CAUTION: Never use a wire, needle, or similar object to cleanODS/pilot. This can damage ODS/pilot unit. POSSIBLE CAUSE 1. ...
Page 18 - OBSERVED PROBLEM; REMEDY; tenance, page 20) or replace burner orifice; POSSIBLE CAUSE
18 105224 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Moisture/condensation noticed on windows Heater pr...
Page 19 - WARNING: If you smell gas; OBSERVED PROBLEM; IMPORTANT
19 105224 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do not use any phone in your b u i l d i n g . • Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup...
Page 20 - WARNING: Turn off heater; and let cool before cleaning.; CAUTION: You must keep; LOGS; Figure 28 - Pilot Inlet Air Hole; SERVICE HINTS; When Gas Pressure Is Too Low; SPECIFICATIONS; Remote Ready; MAIN BURNER
20 105224 UNVENTED PROPANE/LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED CLEANING ANDMAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu-lating air passageways of heaterc l e a n . I n s p e c t t h e s e a r e a s o fhe...
Page 21 - PARTS UNDER WARRANTY; ACCESSORIES; FIREPLACE HOOD; WIRING DIAGRAM; Note
21 105224 OWNER’S MANUAL REPLACEMENTPARTS Note: Use only original replacement parts. This will protect your warranty coverage forparts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. Ifthey can’t supply original replacement part(s),call Fireplace Manufacture...
Page 23 - PARTS LIST; Part Number
23 105224 OWNER’S MANUAL PARTS LIST FVFM27PR This list contains replaceable parts used in your heater. When ordering parts, follow theinstructions listed under Replacement Parts on page 21 of this manual. KEYNO. Part Number DESCRIPTION QTY. 1 104676-01 Log, Multi-Sided 1 2 103778-01 ODS Pilot (LP) 1...
Page 24 - KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC; LIMITED WARRANTY; For information about this warranty write:
KEEP THIS WARRANTY WARRANTY INFORMATION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.We make no other warranty, expressed or im...