Page 2 - TABLE OF CONTENTS
SG UPS Features. . . . . . . 1 SG Series On-line UPS Block Diagram. . . . . 1 Important Safety Instructions (READ FIRST) . . . . 2 Chapter 1. SG Series UPS Overview . . . . . 3 True Regenerative On-line Design . . . . 3 Input Power Factor Correction . . . . 3 Microprocessor Control . . . . . 3 SNMP/...
Page 3 - True Double Conversion On-Line Design
SG SERIES UPS FEATURES SG SERIES ON-LINE UPS SYSTEM BLOCK DIAGRAM True Double Conversion On-Line Design Input Power Factor CorrectionWide Input Voltage WindowPure Sinewave Output Precision Output Voltage Regulation Superior Brownout, Surge and Transient ProtectionInternal System BypassEliminates Gen...
Page 4 - (in watts) must never exceed that shown on the UPS rating label.
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions which must be followed during the installation,operation and maintenance of this UPS and its batteries. Please read all instructions beforeoperating this equipment and save this manual for future refere...
Page 5 - SG Series UPS - Overview; UPS Plus
CHAPTER CHAPTER 1 1 SG Series UPS - Overview True Regenerative On-Line Design As new and innovative technologies have become the backbone of today's businesses, maximum system availability is critical and downtime is more expensive than ever. Increasingly, businesses need a UPS that not only protect...
Page 6 - INSTALLATION INSTRUCTIONS; The UPS is shipped; NO BATTERY BACKUP IS PROVIDED AFTER THE GREEN MODE HAS ACTIVATED.
CHAPTER CHAPTER 2 2 INSTALLATION INSTRUCTIONS 1. Verify the following is included in the UPS shipping carton:(1) UPS, (1) Software Diskette(s) & Manual, (1) Power Cord (800VA-1KVA models only),(1) Owners Manual & (1) UPS/Computer Cable. 2. Verify the UPS unit is configured for the proper inp...
Page 7 - IMPORTANT
5. For SG800VA - SG1kVA and 208-240V models, connect the power cord to the UPS inlet located on the UPS rear panel. On SG1.5K - SG3K 120V models the line cord is permanently attached to the UPS. 6. Select a suitable location for the UPS, near enough to the computer or equipment to to be protected. C...
Page 8 - VOLTAGE; SWITCH SETTINGS FOR -1 MODELS
DIP SWITCHES SELECTION TABLE ON = 1 OFF = 0 SW2 SW1 VOLTAGE Down Down 100V Down Up 110V Up Down 120V (Factory default) Up Up 115V SW2 SW1 VOLTAGE Down Down 220V Down Up 230V (Factory Default) Up Down 240V Up Up 200V SW3 FUNCTION Down GREEN MODE ON Up GREEN MODE OFF SWITCH SETTINGS FOR -1 MODELS SWIT...
Page 9 - TYPICAL EXTENDED BATTERY BANK & UPS INTERCONNECTION; INSTALLATION PROCEDURE FOR EXTENDED BATTERY BANKS; Reinstall the battery fuse.; A popping sound may be heard when inserting the fuse.; Plug the other end of the power cord into a utility receptacle.
TYPICAL EXTENDED BATTERY BANK & UPS INTERCONNECTION (Mini-tower models shown; same applies for floor standing banks) INSTALLATION PROCEDURE FOR EXTENDED BATTERY BANKS 1. Remove the battery fuse located on the UPS rear panel. See illustration above. 2. Locate the battery interconnect cable(s). 3....
Page 10 - SG800VA-3kVA TOWER EXTENDED BATTERY BANK SELECTION GUIDE; FOR 3KVA MODELS
BATTERY OPTION MODELS W/O Charger SGB2S7-1K3 SGB4S7-1K3 SGB5S7-1K3 SGB10S7-1K6 SGB10S7-1K6 BATTERIES 6 Pieces 12V, 7AH 12 Pieces 12V, 7AH 15 Pieces 12V, 7AH 30 Pieces 12V, 7AH 60 Pieces 12V, 7AH BATTERIES IN UPS 3 each of 12V, 7AH # of CASES Inches (mm) 1 Mini-Tower 13.8 x 7.6 x 18.9 (350 x 193 x 48...
Page 11 - OPERATION; UPS FRONT PANEL INDICATOR AND FUNCTION KEYS; LOAD LEVEL INDICATOR LEDS; This LED is lit when the unit is operating from battery.
9 CHAPTER CHAPTER 3 3 OPERATION 1 2 3 4 5 6 7 8 9 10 11 UPS FRONT PANEL INDICATOR AND FUNCTION KEYS 1. LOAD LEVEL INDICATOR LEDS *The first or bottom LED is lit when the output load is greater than 25% of the rated output of the UPS. *The second LED is lit when the output load is greater than 50% of...
Page 14 - CHAPTER; REAR PANEL DETAILS
OPTIONAL EXTERNAL BATTERY CONNECTOR OUTPUT RECEPTACLES (6 places without external battery option, 4 plac es as shown) COVER PLATE FOR OPTIONAL DIP SWITCHES RS-232 CONNECTOR COOLING FAN DO NOT BLOCK INPUT CIRCUIT BREAKER BATTERY FUSE POWER INLET SG800-1T & SG1K-1T Typical Rear Panel Overview SG80...
Page 16 - BREAKER
14 SG2K-1TX, SG2K-2TX, SG2K-1TXI, SG2K-2TXI, SG3K-1TX, SG3K-2TX, SG3K-1TXI & SG3K-2TXI Typical Rear Panel Overview COVER PLATE FOR COMMUNICATIONS SLOT EXTERNAL BATTERY CONNECTOR COVER PLATE OUTPUT FUSES FOR THE TOP RECEPT ACLE 208-240Vac OUTPUT RECEPTCALE 120Vac OUTPUT RECEPTACLE LINE CORD INLET...
Page 17 - COMMUNICATIONS INTERFACES; Function explanation; UPSILON 2000 & SEC Smart Mon; TX; RX; GEN; CAUTION; GND
CHAPTER CHAPTER 5 5 COMMUNICATIONS INTERFACES RS-232 INTERFACE 15 Pin # Function explanation I/O 9 RS 232 Rx INPUT 6 RS 232 Tx OUTPUT 7 Ground Location: The RS-232 interface is standard on all SG series UPS models. The port is located on the UPS rear panel, via a DB-9 female connector. Supported Pro...
Page 19 - OPTO Board Internal Circuitry
17 PIN ASSIGNMENT FOR THE FALCON UA88373 OPTO-COUPLER OPTION BOARD (no-bypass signal) PIN DESCRIPTION 1 Not Used 2 Utility Loss (N.O.) (Closes upon utility loss) 3 Utility Loss (N.C.) (Opens upon utility loss) 4 Common for pins 2, 3 & 5 5 Low Battery (N.O.) (Closes at low battery) 6 Remote Shutd...
Page 21 - Maintenance & Technical Support; WARNING
CHAPTER CHAPTER 6 6 Maintenance & Technical Support 1. Care & Maintenance Falcon ® SG Series UPSs are designed to be maintenance-free. They can be cleaned with a damp cloth or non-abrasive cleanser, providing the UPS is turned off and the input plug is disconnected from the utility source.On...
Page 22 - Storing the UPS and Batteries; which the receiver is connected.
The following precautions should be observed by a qualified technician when working with batteries: 1. Remove watches, rings, or other metal objects. 2. Use tools with insulated handles. 3. Wear rubber gloves and boots. 4. Do not lay tools or metal parts on top of batteries. 4. Storing the UPS and B...
Page 23 - Technical Support; Your FALCON; Requesting Technical Information or Support; Please send your technical or support questions by email to:; FALCON Web Support; Acrobat .PDF format on our corporate website.
6. Technical Support Your FALCON ® Electric SG Series UPS is backed by one of the finest customer service teams assembled. Write, call, fax or email should you require technical assistance or service. Falcon Electric Inc. 5106 Azusa Canyon RoadIrwindale, CA. 91706Service 800.842.6940Voice 626.962.77...
Page 24 - NEW PRODUCT LIMITED WARRANTY; This limited warranty does not cover damage caused by: (i) improper; ALL OTHER WARRANTIES ARE EXPRESSLY DISCLAIMED,
FALCON ELECTRIC, INC. NEW PRODUCT LIMITED WARRANTY Limited Warranty: Falcon warrants that this product will be free from defects in materials and workmanship for a period of two years from the date of shipment by Falcon. Procedures: Any defective product must be returned to Falcon. No product can be...
Page 25 - SG Series; UPS PLUS
SG Series TM UPS PLUS ® 800VA to 1.5kVA Model Number SG800 -1T SG1K-1T SG1K -2T SG1.5K -1T Nominal VA 800 1000 1000 1500 Electrical Input Nominal AC Voltage 120V 120V 230V 120V AC Voltage Range 87-140V 87-140V 170-275V 87-140V Current -Amps 5.5 6.9 3.6 10.7 Frequency 50/60 Hz ± 5% (Auto – Tracking) ...