Page 2 - Precautions; Safety Instructions • English; FCC Class A Notice; Extron’s Warranty
Precautions This symbol is intended to alert the user of importantoperating and maintenance (servicing) instructionsin the literature provided with the equipment. This symbol is intended to alert the user of thepresence of uninsulated dangerous voltage withinthe product's enclosure that may present ...
Page 3 - RCP 2000 • Quick Start Guide; Turn the equipment off; and disconnect it from the power source.; Set; the RCP 2000 on a table or other flat surface.; one of the RS-232 cables provided with the RCP 2000 between; one of the RS-232 cables provided with the RCP 2000 between; Quick Start Guide — RCP 2000
RCP 2000 • Quick Start Guide Step 1 Turn the equipment off and disconnect it from the power source. Make sure that the ISS 108/408 or SGS 408 and all attached devicesare turned off and, if applicable, disconnected from the powersource. Step 2 Set the RCP 2000 on a table or other flat surface. Step 3...
Page 4 - Quick Start Guide — RCP 2000, cont’d; iii; Chapter 1 • Introduction; Table of Contents; Continue
RCP 2000 • Quick Start Guide Quick Start Guide — RCP 2000, cont’d iii RCP 2000 • Table of Contents Chapter 1 • Introduction .......................................................... 1-1 Features ...................................................................................... 1-2 Chapter 2 • I...
Page 5 - Table of Contents, cont’d; RCP 2000 Remote Control Panel; Network Switcher Control; Chapter One; Introduction; Features
iv RCP 2000 • Table of Contents Table of Contents, cont’d RCP 2000 Remote Control Panel Accessing and using the Web pages .................................... 4-4 Logon and system status ................................................. 4-4 Establishing or changing system settings .....................
Page 6 - Chapter Two; Installation; Rear Panel Connectors; Applying and Changing a
RCP 2000 • Introduction Introduction, cont’d RCP 2000 Remote Control Panel 2 Chapter Two Installation Rear Panel Connectors Installation Application Example Making an RCP Communication Cable Introduction The Extron RCP 2000 remote control panel provides completeremote control of a seamless switcher....
Page 7 - AC power connector —; Resetting the Unit
RCP 2000 • Installation Installation, cont’d RCP 2000 • Installation Rear Panel Connectors ETHERNET LINK 120-240VAC 50/60 Hz 1.2A MAX. TO S WITCHER ACT R S -2 3 2 RE S ET 1 4 3 2 5 Figure 2-1 — RCP 2000 rear panel 1 AC power connector — Plug a standard IEC power cord from a 100 to 240 VAC, 50/60 Hz ...
Page 8 - Application Example; Figure 2-2 — RCP 2000 application example; Making an RCP Communication Cable
RCP 2000 • Installation Installation, cont’d RCP 2000 • Installation 2-4 Application Example The following diagram is an example of the RCP 2000 connectedto an ISS 408, along with various input and output devices. Projector Program Monitor Preview Monitor ExtronISS 408 Seamless Switcher ExtronRCP 20...
Page 9 - Chapter Three; Operation; Top Panel Controls; crossover cable; . See the table on the next; When connecting the RCP 2000; patch; table below for RJ-45 patch cable connections.
RCP 2000 • Installation Installation, cont’d RCP 2000 Remote Control Panel 3 2-6 Chapter Three Operation Top Panel Controls Using the Picture Controls Applying and Changing a Switching Effect Resetting the Unit • When connecting the RCP 2000 directly (no intermediate device present, such as a networ...
Page 10 - Applying and Changing a Switching Effect
RCP 2000 • Operation Operation, cont’d RCP 2000 • Operation Operation 3-2 Top Panel Controls FREEZE BLACK 1 2 3 4 5 6 7 8 9 10 11 12 CONT BRIGHT H DIMMER V COLOR TINT WIPE DISOLVE TAKE FREEZE BLACK 1 2 3 4 5 6 7 8 9 10 11 12 PROGRAM ADJUST LAMP PREVIEW COMMUNICATION TxRx DETAIL SIZE CENTER CUT PICTU...
Page 11 - Take button —; Applying and Changing a Switching; Picture control buttons —; Using the Picture; Using the Picture Controls; Adjusting color and tint
RCP 2000 • Operation Operation, cont’d RCP 2000 • Operation 3-4 Wipe button (SGS only) — Causes the preview image to appear to unroll over the program image horizontally orvertically. The different wipe effects include standard,curtain, plus, square, and title window. Take button — Initiates the swi...
Page 12 - Detail adjustments; Cuts; Implementing an effect; Figure 3-2 — A dissolve effect; Changing the duration of a dissolve; Figure 3-3 — Standard wipe transitions
RCP 2000 • Operation Operation, cont’d RCP 2000 • Operation Detail adjustments To apply a horizontal or vertical filter to improve the sharpnessof an image, do the following: 1 . Press and release the Detail button. The button lights. 2 . Various levels of detail adjustment are available,depending o...
Page 13 - Plus wipe; causes the preview image to appear to unroll over; Square wipe; causes the preview image to appear to unroll; Title; causes a predefined box in the program image to dissolve; Selecting a wipe and a wipe duration
RCP 2000 • Operation Operation, cont’d RCP 2000 • Operation Curtain wipe A curtain wipe causes the preview image to appear to unroll over the program image in two directions simultaneously. Acurtain wipe can have either hard (sharp) or soft (fuzzy) edges.The preview image can have the following tran...
Page 14 - Figure 3-8 — Available wipes; Implementing a title; CAUTION; — Pressing and; holding; holding
RCP 2000 • Operation Operation, cont’d RCP 2000 • Operation 3-10 S O F T W I P E L T t o R T S O F T W I P E R T t o L T S O F T W I P E T P t o B M S O F T W I P E B M t o T P S C U R T H R Z I N S C U R T H R Z O U T S C U R T V E R T I N S C U R T V E R T O U T H C U R T H R Z I N H C U R T H R Z...
Page 15 - Chapter Four; Remote Control; Manual IP Setup
RCP 2000 • Operation Operation, cont’d RCP 2000 Remote Control Panel 4 Chapter Four Remote Control Manual IP Setup Network IP Setup and Control Network Switcher Control 3-12 Mode 3 — Pressing and holding the Reset button until the front panel LCD display shows “Reset Mode 3” (10 seconds),then immedi...
Page 16 - Changing the IP addresses; To change the IP addresses:; Figure 4-1 — Setting up for an IP address change; Figure 4-2 — Making the IP address change
RCP 2000 • Remote Control Remote Control, cont’d RCP 2000 • Remote Control 4-2 4-3 Manual IP Setup The RCP 2000 unit ships with default server (ISS) and client(RCP) IP addresses, as well as Subnet Mask and GatewayAddress, already set. These default IP addresses can bechanged to conform to the IP add...
Page 17 - Contacting the RCP unit; Logon and system status; Enter the IP address of the unit (see; Establishing or changing system settings; To change system settings:
RCP 2000 • Remote Control Remote Control, cont’d RCP 2000 • Operation 4-4 4-5 Network IP Setup and Control Once the IP addresses have been changed, if required, you cancontact and control the RCP 2000 by using Web pages that areresident, in firmware, on the RCP unit. Contacting the RCP unit The resi...
Page 18 - Remote Control, cont’d; Figure 4-4 — System Settings screen; Firmware upgrade; From the Configuration tab, click on
RCP 2000 • Remote Control Remote Control, cont’d RCP 2000 • Remote Control Figure 4-4 — System Settings screen 2 . Make changes to the IP Settings, Date/Time settings, etc.,as necessary. 3 . Click the Submit button to enter the changes, or click theCancel button to revert to the previous settings. C...
Page 19 - File management; Figure 4-6 — File Management screen; Accessing network switcher control; Changing the IP
RCP 2000 • Remote Control Remote Control, cont’d RCP 2000 • Remote Control 4-8 4-9 File management The File Management screen is used to upload new files (forcustom or updated Web pages) to the RCP unit and to deleteexisting files from the unit. The File Management screen can beaccessed from the ini...
Page 20 - Appendix; Accessories; Specifications; Figure 4-7— ISS Control screen; Using network switcher control; To use network switcher control, follow these steps:
RCP 2000 • Remote Control Remote Control, cont’d RCP 2000 Remote Control Panel A Appendix Specifications, Parts, and Accessories Specifications Part Numbers 4-10 Figure 4-7— ISS Control screen Using network switcher control To use network switcher control, follow these steps: 1 . Set the level of co...
Page 21 - Part Numbers; Extron Part; Control/remote — control panel; autodetect; General; internal, autoswitchable; Specifications are subject to change without notice.
RCP 2000 • Specifications, Parts, and Accessories Specifications, Parts, and Accessories, cont’d RCP 2000 • Specifications, Parts, and Accessories Part Numbers Extron Part Part Number RCP 2000 60-571-01 RS-232 male-male cable – 2' (.61 m) 26-434-01 RS-232 male-male cable – 4' (1.22 m) 26-434-02 RS-2...
Page 23 - RCP 2000 • Specifications, Parts, and Accessories
RCP 2000 • Specifications, Parts, and Accessories Specifications, Parts, and Accessories, cont’d A-6