Page 2 - Precautions; Safety Instructions • English; Extron’s Warranty
Precautions This symbol is intended to alert the user of importantoperating and maintenance (servicing) instructionsin the literature provided with the equipment. This symbol is intended to alert the user of thepresence of uninsulated dangerous voltage withinthe product's enclosure that may present ...
Page 3 - MKP 2000 Remote Control Panel • Quick Start Guide; Quick Start Guide — MKP 2000
MKP 2000 Remote Control Panel • Quick Start Guide QS-1 Install and set up the MKP 2000 as follows: Step 1 Turn all of the equipment off and disconnect it from the power source. Step 2 Install the cables to and from the control panel in a wall, podium, or desk. See Rear Panel and Side Panel Connectio...
Page 4 - Quick Start Guide — MKP 2000, cont’d; MKP 2000 Remote Control Panel• Table of Contents; Chapter 1 • Introduction; Chapter 3 • Local Operation; Table of Contents; Program the control panel with the size of the connected switcher; See System Settings Page in chapter 5, HTML Operation.; Use the control panel to select inputs and outputs; Operations in chapter 3, Local Operation.
MKP 2000 Remote Control Panel • Quick Start Guide Quick Start Guide — MKP 2000, cont’d i MKP 2000 Remote Control Panel• Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About the MKP 2000 Remote Control Panel ........... 1-2 RS-232 connection ...
Page 5 - Table of Contents, cont’d; MKP 2000 Remote Control Panel; Chapter One; Introduction; About the MKP 2000 Remote Control Panel; Chapter 5 • HTML Operation
ii MKP 2000 Remote Control Panel • Table of Contents Table of Contents, cont’d MKP 2000 Remote Control Panel 1 Chapter One Introduction About the MKP 2000 Remote Control Panel 68-971-01 A 01 05 All trademarks mentioned in this manual are the properties of their respective owners. Symbol definitions ...
Page 6 - Figure 1-1 — Typical MKP 2000 applications; RS-232 connection to the switcher
MKP 2000 Remote Control Panel • Introduction MKP 2000 Remote Control Panel • Introduction Introduction This manual provides installation and operation instructions forthe Extron MKP 2000. About the MKP 2000 Remote Control Panel The MKP 2000 is a network-ready remote control panel that cancontrol any...
Page 7 - Chapter Two; Installation; MKP Installation Overview
MKP 2000 Remote Control Panel • Introduction MKP 2000 Remote Control Panel • Introduction Introduction 2 Chapter Two Installation MKP Installation Overview UL Requirements for Wall Box Installation Installation Procedures Rear Panel and Side Panel Connections 1-4
Page 8 - UL Requirements for Wall Box Installation; Figure 2-1 — MKP mounted in a wall box; Installation Procedures; CAUTION; To install an MKP 2000 remote control panel, follow these steps:
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation 2-3 UL Requirements for Wall Box Installation The following Underwriters Laboratories (UL) requirementspertain to the installation of the MKP 2000 into a wall orfurniture (figure 2-1). MKP 200 0 4 ...
Page 9 - Install the mud ring or wall box as follows:; If you are using a mud ring; , use the template that came; Cut out the wall/furniture material from the marked area.; If you are using a wall box; , feed cables through the wall
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d Preparing the site, installing the mud ring or wallbox Choose a location that allows cable runs without interference.Allow enough depth for both the wall box and the cables. Youmay need to ...
Page 10 - Figure 2-3 — Attaching a mud ring to a wall; , insert the wall box into the; Figure 2-4 — Attaching a wall box to a wall stud; Mounting the MKP to the mud ring or wall box
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d 2-6 7a . If you are using a mud ring , follow the directions, if any, that came with the mud ring to attach the clips that fastenthe ring to the wall or furniture (figure 2-3). To meet the ...
Page 11 - Figure 2-5 — Mounting the MKP to the wall box; Rear Panel and Side Panel Connections; Figure 2-6 — MKP rear and side panels; Ethernet connection indicators; If desired, connect a host computer or; Switcher RS-232 port —; If desired, connect a cable between this; Power connector —; Plug the included external 12 VDC power
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d 3 . Mount the MKP’s faceplate to the mud ring or wall boxwith machine screws (figure 2-5). MK P 200 0 4 5 6 1 2 3 7 8 9 BA CK 0 CANC EL INPUT OUTPUT TA KE R Figure 2-5 — Mounting the MKP to...
Page 12 - Control connections; Figure 2-8 — MKP connection using the RS-232 port; Cut off the foil shield and discard it.
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d Control connections The MKP has two RS-232 ports; a Host port ( 1 ) and a Switcher port ( 2 ); and an Ethernet (LAN) port ( 3 ). An MKP control panel can be directly connected to any Extron...
Page 13 - TP cable termination; Crossover cable —; Direct connection between the MKP; Figure 2-11 — RJ-45 connector and pinout tables
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d TP cable termination It is vital that your Ethernet cables be the correct cables, and thatthey be properly terminated with the correct pinout. Ethernetlinks use Category (CAT) 5e or CAT 6, ...
Page 14 - MKP 2000 Remote Control Panel • Installation; Chapter Three; Local Operation; Front Panel Controls and Indications; Power supply wiring; Figure 2-12 shows how to wire the connector.; Figure 2-12 — Power connector wiring
MKP 2000 Remote Control Panel • Installation Installation, cont’d MKP 2000 Remote Control Panel 3 Chapter Three Local Operation Front Panel Controls and Indications Front Panel Operations Rear Panel Resets 2-14 Power supply wiring Figure 2-12 shows how to wire the connector. Power Supply Output Cord...
Page 15 - Figure 3-1 — MKP 2000 controls and indicators; Front Panel Operations; Creating a tie
MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation 3-2 Front Panel Controls and Indications MKP 2000 4 5 6 1 2 3 7 8 9 BACK 0 CANCEL INPUT OUTPUT TAKE 2 6 3 5 4 1 7 BACK 0 CANCEL Figure 3-1 — MKP 2000 controls and indicators 1 0, 1 through...
Page 16 - Local Operation, cont’d; Viewing the last input or output tied from the MKP; Press either the Input button or the Output button.
MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d When an input or output outside the available range forthis MKP or the connected matrix switcher is selected,the LED display shows N - A . Viewing the last input or output tied fro...
Page 17 - OP; Figure 3-2 — Selecting octet fields and host control; Host control port setting and pass-through communications; Selected as secondary,
MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d 1 9 2 1 6 8 . 2 5 4 2 5 3 . . 2 5 5 2 5 5 . 0 0 0 0 0 0 . . 0 0 0 0 0 0 . 0 0 0 0 0 0 . . 0 0 0 0 0 0 . . . . . . . . . . . . . 0 0 0 0 0 0 . . SEC Pri INPUT OUTPUT TAKE OUTPUT OUT...
Page 18 - Control panel security lockout (executive mode); LOC; Figure 3-3 — Control panel lockout; Rear Panel Resets; Performing soft resets; Figure 3-4 — Soft resets
MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d 3-8 Control panel security lockout (executive mode) The front panel security lockout limits the MKP’s front paneloperation to input and output selection only (IP addressmodificatio...
Page 19 - MKP 2000 Remote Control Panel • Local Operation; Chapter Four; SIS Operation; Ethernet Link; Performing a hard reset; erases all user-installed software or firmware. Perform a; Power; Figure 3-5 — Hard reset
MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d MKP 2000 Remote Control Panel 4 Chapter Four SIS Operation RS-232 Links Ethernet Link Host-to-MKP Instructions MKP-Initiated (Unsolicited) Messages MKP Error Responses Using the Command/Response Table 3-10 Performing a hard rese...
Page 20 - The default protocol for both ports is as follows:; Figure 4-1 — RS-232 connector pin assignments; Routing matrix switcher commands; Default IP address
MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation RS-232 Links The MKP’s rear panel 3-pole, 3.5 mm, Host RS-232 connector(figure 4-1) can be connected to the RS-232 serial port output ofa host device such as a computer running the HyperTerminal...
Page 21 - SIS Operation, cont’d; Login Administrator; MKP Error Responses
MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d This message means that the switcher requires an administratoror user level password before it will perform the commandsentered via this link. The switcher repeats the passwordmessage re...
Page 22 - Symbol definitions for MKP SIS commands; = n=–1= redirect serial port data from the specified port to allow for; = Daylight Savings Time
MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d Symbol definitions for MKP SIS commands = CR/LF (carriage return/line feed) (0x0D 0A) • = space X1 = On/off status 0 = off/disable 1 = on/enable X2 = RS-232 port number 1 = host 2 = swit...
Page 23 - esponse table for MKP SIS commands (continued)
MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d Command/r esponse table for MKP SIS commands (continued) Command ASCII Command Response Additional description (host to M K P ) (M K P to host) 4-8 Command/r esponse table for MKP SIS co...
Page 25 - MKP 2000 Remote Control Panel • SIS Operation; Chapter Five; HTML Operation
MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d MKP 2000 Remote Control Panel 4-14 5 Chapter Five HTML Operation Download the Startup Page System Status Page System Settings Page Port (RS-232) Settings Page Passwords Page Firmware Upgrade Page File Management Page Special Charact...
Page 26 - Figure 5-1 — Enter Network Password page; If neither of the above conditions is true; Download the Startup Page
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation 5-3 5-2 5 . Press the keyboard Enter key. The MKP checks to see if itis password protected. If the MKP is not password protected, proceed to step 7. If the MKP is password protected, the MKP ...
Page 27 - HTML Operation, cont’d; Figure 5-2 — System Status page; System Settings Page; Figure 5-3 — System Settings page
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-5 5-4 System Status Page The System Status page (figure 5-2) provides an overall view ofthe status of the MKP, including various IP addresses, the statusof the Host and Switch RS-23...
Page 28 - IP Settings section; Click the appropriate radio button to select among:; Pass Through selected —; Commands received on the
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-7 5-6 IP Settings section Unit Name field The Unit Name field contains the locally-assigned name of theMKP. This name field can be changed to any valid name, up to24 alphanumeric ch...
Page 29 - Authorized inputs and authorized outputs; Date/Time Settings fields; Figure 5-4 — Port Settings page
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-9 5-8 Authorized inputs and authorized outputs You can use the Authorized Inputs and Authorized Outputsdrop boxes to narrow the number of inputs and outputs that arecontrollable fro...
Page 30 - Figure 5-5 — Passwords page; Firmware Upgrade Page; Figure 5-6 — Firmware Upgrade page
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-11 5-10 Passwords Page Access the Passwords page (figure 5-5) by clicking theConfiguration tab and then the Passwords link on the left sideof the System Settings page. System (IP) S...
Page 31 - Figure 5-7 — Firmware upgrade open file window; File Management Page; Figure 5-8 — File Management page
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-13 5-12 7 . Click the Browse button. An open file window appears(figure 5-7). Figure 5-7 — Firmware upgrade open file window 8 . Navigate to the folder where you saved the firmwareu...
Page 32 - MKP 2000 Remote Control Panel • HTML Operation; Special Characters; Cannot include spaces or underscore characters; Appendix A; Reference Data; Specifications
MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d MKP 2000 Remote Control Panel 5-14 Special Characters The HTML language reserves certain characters for specificfunctions. The MKP will not accept these characters as part ofits name, passwords, or locally created file names. Vali...
Page 33 - Control/remote — keypad; connectors; General; wall box; Specifications are subject to change without notice.; Part Numbers; Included parts; These items are included in each order for an MKP 2000:; Installation accessories; Cables
MKP 2000 Remote Control Panel • Reference Data MKP 2000 Remote Control Panel • Reference Data Reference Data A-3 A-2 Specifications Control/remote — keypad Extron remote key pad control .. (2) 3.5 mm, 3-pole captive screw connectors General External power supply ............... 100 VAC to 240 VAC, 5...
Page 34 - Reference Data, cont’d; Electrical box cutout; Drawn to scale may be used as a template.; VOLUME; Full Size; t area sho
MKP 2000 Remote Control Panel • Reference Data MKP 2000 Remote Control Panel • Reference Data Reference Data, cont’d A-5 A-4 Mounting and Cabling Specifications Electrical box cutout Any standard box that meets the local electrical codes can beused, but boxes from different manufacturers can have di...
Page 35 - MKP 2000 Remote Control Panel • Reference Data; Extron Comm-Link cable
MKP 2000 Remote Control Panel • Reference Data Reference Data, cont’d Extron Comm-Link cable Wire specifications for Extron Comm-Link cable (figure A-2) areas follows: A (red) = 18 AWGB (violet or blue) = 22 AWG (grouped and shielded)C (white) = 22 AWGD (Drain) = 24 AWGE (black) = 18 AWG Comm-Link c...