Page 2 - Eurostyle; USE, INSTALLATION AND MAINTENANCE
2 Dear Customer Thank you for purchasing a Eurostyle Hotplate. Before we continue telling you about this hotplate, we cordially invite you to become part of the Eurostyle family by subscribing to ongoing information and invitations. You will find that the clean lines and modern look of your Eurostyl...
Page 3 - DESCRIPTION OF HOTPLATE; ES700GFDBL
3 Natural U-LPG 1 Ultra rapid gas burner/WOK 14.5 MJ/h 12.6 MJ/h 2 Rapid gas burner 12.0 MJ/h 10.4 MJ/h 3 Semirapid reduced gas burner 5.4 MJ/h 4.9 MJ/h 4 Semirapid gas burner 7.1 MJ/h 6.3 MJ/h 5 Auxiliary gas burner 4.1 MJ/h 3.6 MJ/h 6 Pan stands support 2F7 Pan stands support 1F8 Burner n° 2 contr...
Page 4 - USE
4 USE FIG. 1 FIG. 2 1) BURNERS A diagram is screen-printed above each knob on thefront panel. This diagram indicates to which burnerthe knob in question corresponds. After havingopened the gas mains or gas bottle tap, light theburners as described below: - automatic electrical ignition P u s h a n d...
Page 7 - CLEANING; MAINTENANCE SCHEDULE
7 CLEANING IMPORTANT:Always disconnect the appliance from the gas and electricity mains before carrying out anycleaning operation. 2) HOTPLATE Periodically wash the hot plate, the enamelled stell pan support, the enamelled burner caps “A”, “B” and“C” and the burner heads "T" (see fig. 3 and ...
Page 8 - INSTALLATION; TECHNICAL INFORMATION; ) INSTALLING THE HOTPLATE
8 INSTALLATION FIG. 4 TECHNICAL INFORMATION FOR THE INSTALLER This appliance shall be installed only by authorisedpersonnel and in accordance with themanufacturer’s installation instructions, local gasfitting regulations, municipal codes, electrical wiringregulations, AS/NZS 5601- Gas Installation a...
Page 9 - ) FIXING THE HOTPLATE
9 4) FIXING THE HOTPLATE The hotplate has a special seal which preventsliquid from getting into the cabinet. Strictly complywith the following instructions in order to correctlyapply this seal:- Take off all the movable parts of the hob.- Cut the seal in 4 parts of the necessary length to positionni...
Page 11 - ) ELECTRICAL CONNECTION
11 INSTALLATION 6) ELECTRICAL CONNECTION The appliance is supplied with a 1800 mm longflexible supply lead. The point of attachment for this lead is located at the rear and on the underside of the appliance 380 mm from the right hand side. The voltage and power consumption are detailed on the unders...
Page 12 - ADJUSTMENTS; TAPS LUBRIFICATION; Should a tap being blocked, do not
12 ADJUSTMENTS A l w a y s d i s c o n n e c t t h e a p p l i a n c e f r o m t h eelectricity main before making any adjustments.All seals must be replaced by the technician atthe end of any adjustments or regulations.O u r b u r n e r s d o n o t r e q u i r e p r i m a r y a i radjustment.a) Dat...
Page 13 - CONVERSIONS; ) UNIVERSAL LP GAS TO NATURAL GAS; ) NATURAL GAS TO UNIVERSAL LP GAS
13 CONVERSIONS 8) UNIVERSAL LP GAS TO NATURAL GAS CONVERSION PROCEDURE Appliance models: Gas stainless steel hotplatemodels: 1. Remove each burner cap and burner skirt. 2. Remove the Universal LP Gas main injector with a 7 mm/VF tube spanner and replace with theappropriate size Natural Gas injector ...
Page 14 - 0) REPLACING THE INJECTORS; BURNER ARRANGEMENT ON THE HOTPLATE; TABLE 1
14 CONVERSIONS 10) REPLACING THE INJECTORS The burners can be adapted to different types ofgas by installing injectors suited to the type of gasrequired. To do this, first remove the burner topsusing a wrench “B”. Now unscrew injector “A” (seefig. 10) and fit a injector corresponding to the type ofg...
Page 15 - SERVICING; CABLE TYPES AND SECTIONS; WA R N I N G : M A I N T E N A N C E M U S T O N LY B E
15 FIG. 11 SERVICING Gas hotplate H05 RR - F Section 3 x 0.75 mm 2 TYPE OF TYPE OF SINGLE - PHASE HOTPLATE CABLE POWER SUPPLY CABLE TYPES AND SECTIONS ATTENTION!!! If the power supply cable is replaced, the installer should leave the ground wire (B) longer than thephase conductors (fig. 11) and comp...
Page 16 - TECHNICAL ASSISTANCE AND SPARE PARTS; FOR CUSTOMER SERVICE
16 TECHNICAL ASSISTANCE AND SPARE PARTS Before leaving the factory, this appliance will have been tested and regulated by expert and specialisedpersonnel in order to guarantee the best performances.Any repairs or adjustments which may be subsequently required may only be carried out by qualifiedpers...