Ericsson MPI-II VHF - Manuals

Ericsson MPI-II VHF – Manual in PDF format online.

Manuals:

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10

Summary

Page 2 - TOOLS NEEDED; Page; CAUTION

INTRODUCTION This service section contains the necessary information to align and troubleshoot the MPI-II (136-174 MHz) Per-sonal Radio. This manual includes steps for disassembly andprocedures for replacing surface mount components andintegrated circuits. Preventive maintenance checks are pro-vided...

Page 5 - Figure 4 - Location of Tuning Controls and Test Points

Figure 4 - Location of Tuning Controls and Test Points LBI-38557 LBI-38557 4

Page 6 - TROUBLESHOOTING; SYMPTOM

2. Check power on the lower channel. Adjust C124 in thedirection that increases power output to a level half waybetween the initial lower and upper channel levels. 3. Recheck the upper channel power. If the upper channelpower is reduced, reset to the previous level by adjust-ing C126. 4. Repeat this...

Ericsson Manuals