Page 2 - Safety Precautions
2 FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having j...
Page 3 - Table of Contents
3 Safety Precautions....................................................................................................2Table of Contents......................................................................................................3Codes And Approvals...........................................
Page 4 - Codes And Approvals; IN CANADA
4 DIRECT VENT ONLY: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. ** TOP VENT DV ONLY** This appliance has been tested and approved for installations from 0 feet to 4500 feet (137...
Page 5 - Specifications; inches
5 Specifications D IMENSIONS : �� � � �� � �������� �� � � �� � �������� �� �� � �� � �������� �� � � �� � �������� �� � � �� � �������� �� � � �� � �������� �� � � � � �������� �� � � � � �������� �� � � �� � �������� Height: 24 1 / 16 inches (611 mm) Width: 19 1 / 16 inches (484 mm) Depth: 15 5⁄8 ...
Page 6 - Operating Instructions; FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING.; furnit ure, gasoline or o ther flammable vapors away.; TO TURN OFF GAS TO APPLIANCE; LIGHTING INSTRUCTIONS
Operating Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. L IGHTING I NSTRUCTIONS : 6 CAUTION: Hot while oper ating. Do not touch. Keep children, clothing, furnit ure, gasoline or o ther flammable vapors away. FOR YOUR SAFETY: Do not operate this fireplace with the glass removed, crac...
Page 7 - Component; For Your Safety, Read Safety Precautions And; If not recently done, remove the glass and let the unit air out; Turn on gas to the heater. Leak test all joints; NEVER USE AN OPEN FLAME FOR LEAK TESTING.
2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several times until the pilot light starts. Hold the gas control knob in for thirty (30) seconds. Check that the pilot has fully engulfed the thermocouple assem...
Page 8 - Maintenance And Service; When the fireplace has cooled; , remove the face of the fireplace along with the glass. See; Use a mild glass cleaner and a soft cloth; Depending on the amount of use,; Do not clean the glass; as in the; If the unit does not spark when lighting, the battery in the
8 Maintenance And Service R OUTINE M AINTENANCE : At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame s...
Page 9 - must; be done by a licensed or; The glass must be purchased from an ENVIRO dealer. No substitute
R EPLACING G LASS : The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see P ARTS L IST - C OMPONENTS ). Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is bei...
Page 10 - threads before installing into the brass elbow.; TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY; instructions supplied with the kit.; Remove the glass as shown in the
10 Maintenance And Service F UEL C ONVERSION : Figure 7: Removing valve cap. a) Remove the main burner orifice with a 1⁄2 inch deep socket.b) Put a bead of pipe-thread sealant or approved Teflon tape on the orifice threads before installing into the brass elbow. c) Install the new orifice(s) from th...
Page 12 - Initial Installation; QUALIFIED INSTALLERS ONLY; Note: Must have hearth pad if installed on a
Initial Installation QUALIFIED INSTALLERS ONLY WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. P REPARATION F OR I NSTALLATION : • Remove the packaging from the appliance, and ...
Page 13 - Refer to
13 Initial Installation QUALIFIED INSTALLERS ONLY P LANNING Y OUR I NSTALLATION : When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness...
Page 14 - D E; NOTE: Venting terminals shall not be recessed into walls or siding.
A A D E L B C F B B B J M K G H I Openable Fixed Closed Openable Fixed Closed Termination Cap Air Supply Inlet Gas Meter G G Restriction Zone (Termination not allowed) N O 1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223...
Page 15 - INSTALLATION INSTRUCTIONS:
15 Initial Installation QUALIFIED INSTALLERS ONLY ���� ������� Figure 16: Wire Spacers. it to the inner wall frame using four (4) 11⁄2” wood screws. If a wall is greater than 8” (203mm) in depth, the clearance above the flex must be 43⁄8” (111mm) 6. Apply a bead of Mill-Pac Black sealant to the new ...
Page 16 - Manufacturer
Flue Pipe Adaptor Wall Framing Wall Thimble Fire Stop Exhaust 4" Flex Pipe Combusion Air 6 5 / 8 " Flex Pipe Wire Spacers Horizontal Vent Termination Initial Installation QUALIFIED INSTALLERS ONLY Figure 18: Installation of Fireplace Horizontal Vent Kit. 10. Apply a bead of Mill-Pac Black se...
Page 17 - Intertek WH listing of the appliance.
EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the ...
Page 18 - Refer to Figure 20 to determine were the vent restrictor should be
18 Initial Installation V ENT R ESTRICTOR S ETTING : To access restrictor plate, look at the left hand rear corner of the unit. There is a small rectangular hole in the air jacket. Loosen the 1⁄4” hex head bolt and adjust to the correct setting. Slide the hex bolt to the next setting and retighten t...
Page 19 - location of the appliance.
Initial Installation QUALIFIED INSTALLERS ONLY H ORIZONTAL I NSTALLATION : STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance...
Page 20 - black
the cap assembly. It is important that the vent pipe extend into the vent cap a sufficient distance with a minimum of 11⁄4” (3.2 cm) overlap. Secure the connection between the vent cap pipe and the vent cap by attaching the two sheet metal straps extending from the vent cap assembly into the outer w...
Page 21 - should have a 1⁄4” rise
21 Initial Installation 24" (610mm) Maximum Horizontal 24" (610mm) Minimum Vertical Inside Finished Collar Wall Thimble Horizontal Vent Termination Exterior Wall Surface Insulation Interior Wall Surface If installed on a carpeted surface a hearth is required Interior Wall Surface 2.5" (6...
Page 23 - Roof Pitch
23 Initial Installation QUALIFIED INSTALLERS ONLY Vertical Termination Storm Collar Flashing Roofing nails Elbow Strap elbow strap down to the roof level, as shown in Figure 30. Tighten the clamp around the pipe section. Use a level to make sure the pipe is truly vertical. With roofing nails, secure...
Page 27 - AUTOMATIC SAFETY SHUT DOWN:
27 Initial Installation AUTOMATIC SAFETY SHUT DOWN: If the spill switch is activated and shuts off the main burner the following procedure should be followed.• Is the pilot flame still on? If not, the reason for the fireplace shut down is not the spill switch. • Turn off the pilot flame and turn off...
Page 29 - Always check for gas leaks with a soap
29 Initial Installation G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating...
Page 31 - Secondary Installation; NOTE: The logs are
31 Secondary Installation I NSTALLATION OF L OG S ET AND E MBERS : The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner come with four (4) locator pins (see Figure 48), and the bottom logs have ledges whic...
Page 32 - ALL
32 Figure 51. Log Placement Step 3. Secondary Installation 3. A bag of ceramic fiber embers and rock wool embers is provided gently remove the ember material from the plastic bag. Spread a layer loosely across the burner tray. Do not allow any embers to rest against pilot assembly. (See diagram prov...
Page 33 - CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED.
I NSTALLATION OF O PTIONAL B LOWER : Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage is noticed call your dealer, distributor or courier company and have components replaced.Place the fan assembly behind the unit and secure with the two screws provided (a...
Page 34 - Trouble Shooting
Trouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for. The gas valve may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degrees above ambient temperature. Problem wit...
Page 35 - Parts List; Reference
35 Parts List Reference Number Description Part Number 1 120°F (49°C) Ceramic Fan Temperature Sensor EC-001 2 S.I.T. Nova Valve Convertible 50-1421 3 Thermocouple EC-009 Spark Electrode with Ignitor Cable EC-011 3 Thermopile EC-012 3 Pilot Orifice NG Threaded EC-019 3 Pilot Orifice LP Threaded EC-02...
Page 38 - Parts Diagram; SC
Parts Diagram A SC O T -C om po ne nts D ec em be r2 00 4 �� �� �� �� �� � �� � �� � �� �� �� � � � �� � �� �� � � 38
Page 39 - Warranty; Limited Lifetime Warranty:; exclusions apply to this warranty.; To the Dealer; Sign and verify that work and information are correct.; Exclusions and Limitations:; Limited Warranty does not apply.
39 Warranty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the finest materials...
Page 40 - and as such is not covered under this warranty.
Warranty 4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs of neglect or misuse, it is not covered under the terms of this Warranty policy. Performance problems due to operator error will not be covered by the...
Page 42 - Installation Data Sheet; INSTALLER’S SIGNATURE:
42 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ ___________________...