Page 2 - Safety Precautions
2 FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having j...
Page 3 - Table of Contents
3 Table of Contents Safety Precautions..........................................................................................2 Table of Contents............................................................................................3 Codes And Approvals...........................................
Page 4 - Codes And Approvals
DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 ft to 4500 ft (1372 m) above sea level. In the USA:...
Page 5 - Specifications; The rating label is found inside the right cabinet side panel.
5 Specifications D IMENSIONS : 25" (635 mm) 21" (533 mm) 12 1 / 2 " (318 mm) 4 5 / 8 " (117 mm) 29 1 / 8 " (740 mm) Shipping Weight 256 lbs (116 kg) Figure 1: EG40 Exterior Dimensions. R ATING L ABEL L OCATION : The rating label is found inside the right cabinet side panel.
Page 6 - Operating Instructions; FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING.; clothing, furniture, gasoline or other flammable vapors away.
Operating Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. L IGHTING I NSTRUCTIONS : 6 1. STOP! Read the safety information above on this label.2. Turn off all electrical power to this appliance.3. Turn off the gas control knob clockwise to the off position. 4. Open door. Wait fIve (5)...
Page 7 - Component
Figure 4: Gas Valve. Figure 3: Pilot Burning. 7 • There is a separate venturies for each burner, see Figure 5. • Remove one screw from the cover plate located below the ash shelf and loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in plac...
Page 8 - Maintenance and Service; Allow the glass to cool before cleaning.
8 Maintenance and Service Annually check to ensure that your Venting system is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with no or very small yellow tips. O P...
Page 9 - Proceed only when the unit has
9 Figure 8: Blower (Fan) Removal. 1. Turn the unit off, allow it to cool down completely, and remove the door as shown in the M AINTENANCE AND S ERVICE - O PENING T HE D OOR .. 2. Remove the log set and brick liner.3. Remove the burner tray assembly, see M AINTENANCE AND S ERVICE - B URNER R EMOVAL ...
Page 10 - Maintenance And Service; threads before installing into the brass elbow.; TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY; instructions supplied with the kit.; Remove the glass as shown in the
Maintenance And Service F UEL C ONVERSION : Figure 9: Removing valve cap. a) Remove the main burner orifice with a 1⁄2 inch deep socket.b) Put a bead of pipe-thread sealant or approved Teflon tape on the orifice threads before installing into the brass elbow. c) Install the new orifice(s) from the k...
Page 12 - Initial Installation; QUALIFIED INSTALLERS ONLY; circulation and comfort.
Initial Installation QUALIFIED INSTALLERS ONLY WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. P REPARATION F OR I NSTALLATION : • Remove the packaging from the appliance, and ...
Page 15 - NOTE: Venting terminals shall not be recessed into walls or siding.; D E
1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the requirements of the gas supplier. t A vent s...
Page 16 - it to the inner wall frame using four (4) 11⁄2” wood screws. If a wall is; INSTALLATION INSTRUCTIONS:
16 Initial Installation QUALIFIED INSTALLERS ONLY ���� ������� Figure 19: Wire Spacers. it to the inner wall frame using four (4) 11⁄2” wood screws. If a wall is greater than 8” (203mm) in depth, the clearance above the flex must be 43⁄8” (111mm) 6. Apply a bead of Mill-Pac Black sealant to the new ...
Page 17 - Manufacturer
Flue Pipe Adaptor Wall Framing Wall Thimble Fire Stop Exhaust 4" Flex Pipe Combusion Air 6 5 / 8 " Flex Pipe Wire Spacers Horizontal Vent Termination Initial Installation QUALIFIED INSTALLERS ONLY Figure 21: Installation of Fireplace Horizontal Vent Kit. 10. Apply a bead of Mill-Pac Black se...
Page 18 - Intertek WH listing of the appliance.
18 EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect t...
Page 21 - the proper clearances to combustible materials are maintained.
wall thimble will conceal it (see left image in Figure 26). 7. Slide the decorative wall thimble up to the wall surface and attach with the screws provided. Apply decorative brass or chrome trim if desired (see right image in Figure 26). NOTES: • The four wood screws provided should be replaced with...
Page 25 - ‘A’ C; until this vent reaches the CLASS ‘A’ chimney. Install the retro
25 V ENTING INTO A C LASS ‘A’ C HIMNEY : This model is also certified and tested to vent into CLASS ‘A’ wood stove chimneys.Place the freestanding direct vent appliance in the desired location.Use a conversion kit from Simpson Duravent (931, 932, or 933), or Security Chimney (SV4CCK1, SV4CCK2, or SV...
Page 27 - Always check for gas leaks with a soap; NEVER USE AN OPEN FLAME FOR LEAK TESTING.
Initial Installation G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating in...
Page 28 - Secondary Installation; NOTE: The logs are fragile and should be handled gently.
CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required. The use of other foreign materials on the burners may create dangerous conditions.If over time, through cleaning and servicing, these embers req...
Page 29 - CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED.; ALL
29 Secondary Installation CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED. Place the log set into the firebox. Locate each log by seating it down onto the burner tray support pins. Follow Figures 31 to 34 proper log placement.Upon the first light up, watch for ignition to ALL burne...
Page 30 - Trouble Shooting
Trouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for. The gas valve may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degrees above ambient temperature. Problem wit...
Page 31 - Parts List
31 Parts List Reference Number Part Description Part Number 1 120 °F (49 °C) Ceramic Temperature Sensor EC-001 2 S.I.T. NOVA Valve Convertible 50-1421 3 Thermocouple EC-009 3 Spark Electrode with Ignitor Cable EC-011 3 Thermopile EC-012 3 Fully Assembled Pilot NG EC-015 3 Fully Assembled Pilot LP EC...
Page 33 - Parts Diagram - Chassis
33 Parts Diagram - Chassis �� � �� �� �� �� �� �� �� �� � �� EG 40 Body (Chassis) July 2004
Page 35 - Warranty; TO THE DISTRIBUTOR
35 Warranty Sherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This limited lifetime warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location Covered under the life...
Page 36 - Installation Data Sheet
36 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ ___________________...