Page 2 - Safety Precautions
FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having jur...
Page 3 - Table of Contents
Table of Contents 3 Safety Precautions...............................................................................2Table of Contents.................................................................................3Codes And Approvals...................................................................
Page 4 - In Canada; Warnock Hersey; This ENVIRO EG28 DV Fireplace:; IN CANADA; Codes And Approvals
DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. In the ...
Page 5 - Specifications; The rating label is found inside the right cabinet side panel.
5 Specifications D IMENSIONS : 22" (559 mm) 19" (483 mm) 11" (279 mm) 4" (102 mm) 27 1 / 2 " (699 mm) Shipping Weight 210 lbs (95 kg) Figure 1: EG28 Exterior Dimensions. R ATING L ABEL L OCATION : The rating label is found inside the right cabinet side panel.
Page 6 - Operating Instructions; FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING.
6 Operating Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. L IGHTING I NSTRUCTIONS : Figure 2: Lighting Instructions. Repoussez le bouton et tenez. Après la veilleuse a été allumée tenez le bouton pour 30 secondes. Degagez le bouton; si la veilleuse a eteint, repetez les etapes 4 et ...
Page 7 - Component
Figure 4: Gas Valve. Figure 3: Pilot Burning. tips, are not getting enough air. Open the venturi until the flames clean up. If the venturi is opened, or closed all the way, and the correct flames cannot be attained, turn off the gas and contact the dealer. Figure 5: Venturi Adjustment. Operating Ins...
Page 8 - Maintenance and Service; Allow the glass to cool before cleaning.
Maintenance and Service Periodically check to ensure that your direct vent system is clean.Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with no or very small yellow tips...
Page 9 - Proceed only when the unit has
9 Maintenance and Service C LEANING P LATED S URFACES : It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes. To avoid this, give the face a quick wipe with denatured alcohol on a soft cloth BEFORE lighting the fireplace. Never clean the face when ...
Page 10 - Maintenance And Service; threads before installing into the brass elbow.; TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY; instructions supplied with the kit.; Remove the glass as shown in the
Maintenance And Service F UEL C ONVERSION : Figure 9: Removing valve cap. 5. Convert the burner orifice(s): a) Remove the main burner orifice with a 1⁄2 inch deep socket.b) Put a bead of pipe-thread sealant or approved Teflon tape on the orifice threads before installing into the brass elbow. c) Ins...
Page 12 - Initial Installation; QUALIFIED INSTALLERS ONLY; circulation and comfort.; CLEARANCES MUST BE SUFFICIENT TO ALLOW
Initial Installation QUALIFIED INSTALLERS ONLY WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. P REPARATION F OR I NSTALLATION : • Remove the packaging from the appliance, and ...
Page 15 - D E; NOTE: Venting terminals shall not be recessed into walls or siding.
A A D E L B C F B B B J M K G H I Openable Fixed Closed Openable Fixed Closed Termination Cap Air Supply Inlet Gas Meter G G Restriction Zone (Termination not allowed) N O 1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223...
Page 16 - Quantity Description; INSTALLATION INSTRUCTIONS:
���� ������� Figure 19: Wire Spacers. Figure 20: Wire Spacer in Place. the structure. 5. Project a level line from the center point of the elbow. Using this center point, scribe a 10” (25.4 cm) hole or square on the wall. Cut the hole out on both the interior and exterior wall surface. Initial Insta...
Page 17 - vent to ensure a watertight seal.
17 Initial Installation QUALIFIED INSTALLERS ONLY Figure 21: Assembly of Venting Kit. Wall framing Horizontal wall termination Wall thimble fire stop Inside finished collar Decorative brass rings Exhaust 4" flex pipe Combustion air 6 5 / 8 " outer pipe Flue pipe adaptor 11. Stretch the liner...
Page 18 - Do not slip the outer sections of pipe together, you will; Manufacturer
Initial Installation QUALIFIED INSTALLERS ONLY 18 16. Slide the 90° elbow over the flex pipe. Do not slip the outer sections of pipe together, you will require some movement in these pipe section in order to secure the flex pipe to the flue outlet on the appliance. 17. Stretch the flex liner to a le...
Page 22 - the proper clearances to combustible materials are maintained.
wall thimble will conceal it (see left image in Figure 26). 7. Slide the decorative wall thimble up to the wall surface and attach with the screws provided. Apply decorative brass or chrome trim if desired (see right image in Figure 26). NOTES: • The four wood screws provided should be replaced with...
Page 26 - ‘A’ C; until this vent reaches the CLASS ‘A’ chimney. Install the retro
V ENTING INTO A C LASS ‘A’ C HIMNEY : This model is also certified and tested to vent into CLASS ‘A’ wood stove chimneys.Place the freestanding direct vent appliance in the desired location.Use a conversion kit from Simpson Duravent (931, 932, or 933), or Security Chimney (SV4CCK1, SV4CCK2, or SV4CC...
Page 28 - Always check for gas leaks with a soap; NEVER USE AN OPEN FLAME FOR LEAK TESTING.
Initial Installation G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating in...
Page 29 - Secondary Installation; NOTE: The logs are fragile and
29 Secondary Installation I NSTALLATION OF L OG S ET AND E MBERS : The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner come with five (5) locator pins and two (2) resing areas, which make alignment easier...
Page 30 - CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED.; ALL
Secondary Installation CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED. 3. Place the log set into the firebox. Locate each log by seating it down onto the burner tray support pins. Follow Figures 11 to 16 proper log placement.4. Upon the first light up, watch for ignition to ALL bu...
Page 31 - Trouble Shooting
31 Trouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for. The gas valve may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degrees above ambient temperature. Problem ...
Page 32 - Parts List
Parts List Reference Number Part Description Part Number 1 120°F (49°C) Ceramic Temperature Sensor EC-001 2 Thermocouple EC-009 2 Spark Electrode with Cable EC-011 2 Thermopile EC-012 2 Pilot NG with Electrode EC-013 2 Pilot LP with Electrode EC-014 2 Fully Assembled Pilot NG EC-015 2 Fully Assemble...
Page 34 - Parts Diagram - Chassis
Parts Diagram - Chassis EG 28 Body (Chassis) DV April 2006 �� �� � �� �� � �� � �� �� �� �� �� �� �� 34
Page 36 - Warranty; Limited Lifetime Warranty:; exclusions apply to this warranty.; To the Dealer; Sign and verify that work and information are correct.; Exclusions and Limitations:; Limited Warranty does not apply.
Warranty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the finest materials an...
Page 37 - and as such is not covered under this warranty.
37 Warranty 4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs of neglect or misuse, it is not covered under the terms of this Warranty policy. Performance problems due to operator error will not be covered by ...
Page 39 - Installation Data Sheet
39 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ ___________________...