Page 2 - SAFETY PRECAUTIONS; NOTE; GENERAL; Installation and repair should be done by a; Do not operate with cracked or broken
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" ROOM HEATER, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: • All "ENVIROGAS" gas-fired appliances must be installed in accordance with these instructions. Carefully read all the instructions in this manual...
Page 3 - TABLE OF CONTENTS; ENVIROGAS 40 (FIREPLACE INSERT) VENTED ROOM HEATER
TABLE OF CONTENTS 1 Code Approvals ..................................................................................................... 3 2 Specifications ......................................................................................................... 3 3 Assembly and Installation Instruct...
Page 4 - ASSEMBLY AND INSTALLATION INSTRUCTIONS; PREPARATION FOR INSTALLATION; Do not use the unit if it is damaged.; ASSEMBLING AND INSTALLING YOUR ENVIROGAS APPLIANCE
3. ASSEMBLY AND INSTALLATION INSTRUCTIONS PREPARATION FOR INSTALLATION • Remove the packaging from the appliance, surround panels and log set, check to make sure there is no damage. Carefully check the glass door. Do not use the unit if it is damaged. In the event damage is found please report it to...
Page 5 - DECIDING WHERE TO LOCATE YOUR STOVE
4.DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: A. Mantle pillar to stove 10"/ 25 cm B. Stove to 8" wide mantle 12"/ 31 cm Stove must sit on a non-combustible surface, the width and depth of the insert Maintain sufficient clearances for operation, service and maintenance OTHER DIMENSIO...
Page 6 - VENT TERMINAL CLEARANCES
VENT TERMINAL CLEARANCES A= Clearance above grade, verandah, porch, deck, or [balcony (*12 inches (30 cm) minimum] B= Clearance to window or door that may be opened [*12 inches (30 cm) minimum] C= Clearance to permanently closed window [minimum 12 inches (30 cm) recommended to prevent condensation o...
Page 7 - VENTILATION AIR. THESE OPENINGS MUST NOT BE BLOCKED.
5. VENTING WARNING; THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AIR FROM THE ROOM. IT IS ALSO DESIGNED TO DRAW ROOM AIR FOR PROPER HEAT CIRCULATION FROM THE SIDES OF THE UNIT. BLOCKING OR MODIFYING THE LOUVERS IN ANY WAY CAN CREATE HAZARDOUS SITUATIONS, EITHER ...
Page 8 - INSTALLATION OF LOG SET and EMBERS; DO NOT PLACE EMBERS ON THE REAR BURNER.; CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED; INSTALLING THE LOGSET; all
6. INSTALLATION OF LOG SET and EMBERS INSTALLING THE GLOWING EMBERS A bag of ceramic fiber embers is provided for use on the front burner ember tray. CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than requ...
Page 9 - OPERATING INSTRUCTIONS; FOR YOUR SAFETY READ BEFORE OPERATING; LIGHTING INSTRUCTIONS; gas; TO TURN OFF GAS TO
7.OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must be lit by hand by following these i...
Page 10 - ROUTINE MAINTENANCE; Do not clean glass when hot; LUBRICATING THE BLOWERS; EVERY 6 MONTHS
8. ROUTINE MAINTENANCE Periodically check to ensure that the "B-Vent" venting system is clear and that a negative draft is present when the unit is operating. Periodically check the pilot and burner flames CLEANING OF GLASS Do not clean glass when hot It will be necessary to clean the cerami...
Page 12 - GAS LINE CONNECTION; ORIFICE SIZES, PRESSURE AND BTU’S; NEVER USE AN OPEN FLAME FOR LEAK TESTING
10. GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S NATURAL GAS PROPANE GAS FRONT BURNER #48 (1.93 mm) #55 (1.32 mm) REAR BURNER #41 (2.49 mm) #54 (1.40 mm) Manifold pressure. 3.8” wc (.95 kpa) 11” wc(2.74 kpa) Min. Manifold pressures. 1.1” wc (.27 kpa) 2.7” wc(.67 kpa) Supply Pressure. 7.0” w...
Page 13 - ELECTRICAL REQUIREMENTS; CAUTION; Label all; WARNING; INSTALLING REMOTE THERMOSTAT OR WALL SWITCH; RECOMMENDED WIRE SIZE
11. ELECTRICAL REQUIREMENTS The ENVIROGAS EG-40 FPI. BV. will operate without an external electrical power supply. This model has a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burners. The appliance when installed, must be electrically connecte...
Page 14 - PARTS AND ACCESSORIES; Service Parts available from your local Envirogas Dealer; Accessories
12. PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve Piezo Igniter Burner Switch B-vent Spill switch 300 ° F(149 ° C) MR. Orifice Blank Convection Blo...
Page 15 - FUEL TYPE CONVERSION
• There is a separate air shutter for each burner. • Remove one screw from the cover plate located below the ash shelf. Loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place. • With along screwdriver rotate spring clips to open or clos...
Page 16 - To the Dealer
16 13. WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifetime warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location Covered under the lifetime warrant...
Page 17 - INSTALLATION DATA SHEET
14. INSTALLATION DATA SHEET The installer for warranty purposes and future reference must record the following information. Model: EG 40 FPI Name of Owner: __________________________________________ Address: __________________________________________ __________________________________________ ______...