Page 2 - SAFETY PRECAUTIONS; CAREFULLY READ THE FOLLOWING INFORMATION:; Installation and repair should be done by a; Always keep the appliance area clear; Do not operate with
2 SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: GENERAL • Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualif...
Page 3 - WH; ASSEMBLY INSTRUCTIONS; PREPARATION FOR INSTALLATION
TABLE OF CONTENTS Safety Precautions 2 Code Approvals 3 Deciding where to locate your stove 4 Planning your installation 6 Installation of Log Sets and Embers 14 Operating Instructions 15 Maintenance and Technical 16 Trouble Shooting 17 Gas Line Connection 18 Electrical 19 Parts and Accessories 20 F...
Page 4 - DECIDING WHERE TO LOCATE YOUR STOVE; IN CANADA
DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: FIG. 1 Front Width: 22"/ 56 cm Rear Width: 22"/ 56 cm Height: 27-1/2"/ 70 cm* Depth 19"/ 48 cm (*not including vent coupling) Shipping Weight: 210 lbs/95 kg CLEARANCES: A. Side wall to stove 10"/ 25 cm B. Rear wall to stove 4"/ ...
Page 5 - VENT TERMINAL CLEARANCES; VENT RESTRICTOR RING:
VENT TERMINAL CLEARANCES A= Clearance above grade, verandah, porch, deck, or balcony [*12 inches (30 cm) minimum] 5 B= Clearance to window or door that may be opened [*12 inches (30 cm) minimum] C= Clearance to permanently closed window [minimum 12 inches (30 cm) recommended to prevent condensation ...
Page 6 - Simpson Duravent Parts; PLANNING YOUR INSTALLATION
These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE "GS" PIPE FOR GAS STOVES. SECURITY VENTING SYSTEMS (SECURE VENT) Kits are available for vertical venting or horizontal venting. It is recommended that a bead of RTV High Temperature Silicone be applied...
Page 7 - HORIZONTAL INSTALLATION
When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10-inches (254mm), 1 ½ inches clearance to combustibles must be maintained. Se...
Page 9 - VERTICAL INSTALLATION
VERTICAL INSTALLATION STEP 1. Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters , or other nearby combustible surfaces. Do not pack air spaces with insulation. STEP 2. Set the gas appliance in the desire...
Page 11 - CATHEDRAL CEILING INSTALLATION; SHERWOOD INDUSTRIES LTD VENTING KITS
CATHEDRAL CEILING INSTALLATION STEP 1. Follow installation steps 1 and 2 under Vertical Termination. STEP 2. Using the plumb bob, mark the centerline of the venting system on the ceiling and drill a small hole through the ceiling and roof at this point. From the roof, locate the drill hole and mark ...
Page 13 - VENTING INTO CLASS “A” CHIMNEYS; Mobile Home
VENTING INTO CLASS “A” CHIMNEYS Simpson GS Dura vent cap Cap Adapter Class “a Chimney Roof Flashing 4” flex liner inside Class “A” chimney Ceiling rafters Retro adapter GS Simpson Dura Vent pipe 4” x 6 5/8” This model is also certified and tested to vent into CLASS “A” wood. stove chimneys Place the...
Page 14 - INSTALLING THE GLOWING EMBERS; CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED; INSTALLING THE LOGSET
INSTALLATION OF LOGSET and EMBERS INSTALLATION OF LOGSET and EMBERS INSTALLING THE GLOWING EMBERS INSTALLING THE GLOWING EMBERS A bag of Rock Wool embers is provided for use on the burner. A bag of Rock Wool embers is provided for use on the burner. CAUTION: Use only the type of ember material suppl...
Page 15 - OPERATING INSTRUCTIONS; LIGHTING INSTRUCTIONS; TO TURN OFF GAS TO
OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must be lit by hand by following these ins...
Page 16 - MAINTENANCE AND TECHNICAL; OPENING THE DOOR; Do not clean glass when hot; FOR CLEANING THE INSIDE OF THE FIREBOX
MAINTENANCE AND TECHNICAL Periodically check to ensure that your "Direct Vent" system is clear. Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with small yellow ti...
Page 17 - TROUBLE SHOOTING
TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of spark igniter Defective piezo igniter Check connections to igniter -If igniter connections are good but there is no spark-replace igniter Broken spark electrode -Check for broken ceramic insula...
Page 18 - GAS LINE CONNECTION; ORIFICE SIZES, PRESSURE AND BTU’S; NATURAL GAS PROPANE; ON THE INSIDE OF THE RIGHT HAND SIDE PANEL.; NEVER USE AN OPEN FLAME FOR LEAK TESTING
GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S NATURAL GAS PROPANE GAS Main Orifice #42 dms #53 dms Manifold pressure. 3.8” wc (0.95 kPa) 11” wc (2.74 kPa) Min. Manifold pressure. 1.1” wc (0.27 kPa) 2.7” wc (0.67 kPa) Supply Pressure. 7.0” wc (1.74 kPa) 12” wc (2.98 kPa) Min. Supply pressure....
Page 19 - DO NOT; INSTALLING REMOTE THERMOSTAT OR WALL SWITCH; CAUTION
The ENVIROGAS EG 28.FS.DV. will operate with no external power supply. These models have a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burner. The appliance when installed, must be electrically connected and grounded in accordance with local co...
Page 20 - PARTS AND ACCESSORIES; Service Parts available from your local Envirogas Dealer; Accessories; The blower does not require lubrication.
PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve Piezo Igniter Burner Switch B-vent Spill switch 220 ° Orifice Blank Convection Blower Light Bulb Hold...
Page 21 - ADJUSTING THE VENTURI; FUEL CONVERSION
ADJUSTING THE VENTURI 21 • Remove the ash shelf by undoing the screw at each end, pull shelf towards you. • Remove one screw from the cover plate located below the ash shelf. Loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place. • Wit...
Page 22 - WARRANTY; WHEN FILING A WARRANTY CLAIM PLEASE COMPLETE THE FOLLOWING; To the Dealer
22 WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifetime warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location Covered under the lifetime warranty ar...
Page 23 - PARTS LIST
23 PARTS LIST EC-001 120 ° F CERAMIC TEMP SENSOR EG28-108 FREESTANDING PEDESTAL EC-002 220 ° F CERAMIC SPILL SWITCH EG28-109 FS PEDESTAL DOOR EC-006 SIT NOVA 820 NG VALVE 50% EG28-116 BURNER TRAY TOP EC-007 SIT NOVA 820 LP VALVE 50% EG28-120 FS DV OWNERS MANUAL EC-009 THERMOCOUPLE (POST 10/00) EG28-...
Page 24 - EG28 FREESTANDING; EXPLODED; Page 2 of 2 JULY 2001
24 FIREBOX GOLD BAR EG28-128 FS BV STOVE TOP EG28124 FS DV STOVE TOP EG28-126 FS PEDESTAL DOOR EG28-109 FS PEDESTAL DOOR MAGNET EG28-056 FREESTANDI NG PEDESTAL EG28 108 UPPER GOLD BARS EG28-129 LOWER GOLD BAR EG28-130 DOOR MAGNET AND BRACKET FS CABINET SIDE PANEL EG28-123 BV TOP BAFFLE EG28-132 DV T...
Page 25 - EG28 DOOR AND GAS TRAY ASSEMBLY; Page 1 of 2 JULY 2001
25 EG28 DOOR AND GAS TRAY ASSEMBLY EXPLODED Page 1 of 2 JULY 2001 GLASS RETAINER GLASS SET WITH TAPE EG28-097 GLASS EXTRUSIONS INNER DOOR WITH GLASS (B) EG28-103 DOOR LATCH BOLT EC-059 OUTER DOOR PAINTED OR GOLD (A) EG28-100 , 102 PAINTED DOOR ASSEMBLY WITH GLASS (A+B) EG28-099 GOLD DOOR ASSEMBLY WI...
Page 26 - INSTALLATION DATA SHEET; Model: EG 28 Direct Vent
INSTALLATION DATA SHEET The installer for warranty purposes and future reference must record the following information. Please keep this information for your records. Model: EG 28 Direct Vent Name of Owner: __________________________________________ Address: _________________________________________...