Page 2 - Safety Precautions
FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having jur...
Page 3 - Table of Contents
Table of Contents Safety Precautions.....................................................................................................2 Table of Contents......................................................................................................3 Codes And Approvals........................
Page 4 - Codes And Approvals
DIRECT VENT ONLY: This type is identified by the prefix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. In ...
Page 5 - chained to the fireplace.; Specifications; INSTALLATION OPTIONS:; • Parallel to a wall or placed in a corner
Main vent diameter 6 1 / 2 " The center of the ducting hook-ups are 10 3 / 16 " from the center of the main vent. Gas/electrical inlets are the same on both sides. 20 3 / 8 " (51 8m m) 7 5 / 16 " (18 6m m) 44 5 / 8 " (11 34m m) 39 5 / 8 " (10 06m m) 6 1 / 8 " (15 5m m) 8 ...
Page 6 - Operating Instructions
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. P ILOT L IGHTING I NSTRUCTIONS : Figure 2. Lighting instruction label. CAUTION: Hot while operating. Do not touch. Severe burns may result. Keep children...
Page 7 - If not recently done, remove the glass and let the unit air out; NEVER USE AN OPEN FLAME FOR LEAK TESTING
Operating Instructions P ILOT L IGHT : 1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE AN OPEN FLAME FOR LEAK TESTING....
Page 8 - TO TURN GAS FIREPLACE OFF
Operating Instructions B URNER L IGHTING : A) Make sure the pilot is lit. B) Turn gas control knob COUNTER CLOCKWISE to ON. C) Flip the burner switch to ON. D) Turn HI/LO knob to the desired flame height. E) Turn on all electrical power to the unit. NOTE: Check that all burner holes are lit. TO TURN...
Page 9 - Maintenance And Service
Maintenance And Service R OUTINE M AINTENANCE : At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame sho...
Page 10 - To avoid this, give the face a quick wipe with
Maintenance And Service C LEANING D ECORATIVE S URFACES : Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and ...
Page 11 - TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY
F UEL C ONVERSION : Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fir...
Page 12 - Initial Installation; QUALIFIED INSTALLERS ONLY; no insulating material can be
Gas Inlet Electrical Line 49" (1245mm) 2 1 / 8 " (54mm) 7 3 / 8 " (187mm) 45" (11 43m m) 21 5 / 8 " (54 9m m) Initial Installation QUALIFIED INSTALLERS ONLY I NTRODUCTION : This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, heart...
Page 14 - TILED FINISH
Figure 15. Floor Level Hearth Requirements With Dimensions Around Opening. Figure 14. Raised Fireplace with Raised Hearth F IREPLACE S URROUND : NOTE: Any paint that is applied to the mantel or facing above the unit should be “heat resistance” or it may discolour. Initial Installation QUALIFIED INST...
Page 16 - NOTE: Venting terminals shall not be recessed into walls or siding.; D E
1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the requirements of the gas supplier. t A vent s...
Page 17 - WARNING: This gas appliance must
Initial Installation QUALIFIED INSTALLERS ONLY V ENTING : This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” PIPE FOR GAS STOVES, SECURITY CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, and MDV SELKIRK METALBESTOS. 2" (51mm) 5" (127mm) 12 5 / 16 ...
Page 18 - except
Note: 0,0 represents a 90° bend directly off the top of the unit. 5 4321 0' (0m) 0' (0 m ) 5' (1 .5 2m ) 10 '(3 .0 5m ) 4' (1.22m) 15 '(4 .5 7m ) 10' (3.06m) 20' (6.11m) 30' (9.17m) Ve nt R es tric to rC on fig ura tio n 40' (12.19m) Figure 20. Possible Vent Configurations Figure 21. Possible Vent R...
Page 19 - the possibility of a fire.
19 Wall framing Horizontal wall termination Wall thimble fire stop Exhaust flex pipe Combustion air outer pipe Elbow Initial Installation QUALIFIED INSTALLERS ONLY H ORIZONTAL T ERMINATION : NOTES:1. Horizontal pipes must not be level. For every 12 inches (305 mm) of horizontal travel (away from the...
Page 21 - corrosion resistance.; Roof Pitch
21 Initial Installation QUALIFIED INSTALLERS ONLY STEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of sufficient size to meet minimum requirements for Clearance to Combustibles, as specified. Continue to assemble lengths of pipe and elbows ne...
Page 24 - DO NOT
24 Initial Installation QUALIFIED INSTALLERS ONLY E LECTRICAL R EQUIREMENTS : The fireplace must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTAL...
Page 25 - Always check for gas leaks with a soap; NEVER USE AN OPEN FLAME FOR LEAK TESTING.
25 Initial Installation G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating...
Page 26 - Secondary Installation; WARNING: DO NOT INSTALL LINER IF UNIT IS HOT.
L OG S ET AND E MBER I NSTALLATION : The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner (Figure 34) and a few of the logs come with locator pins, notches, and ledges which make alignment easier. The andi...
Page 28 - right of center, log
Secondary Installation Figure 40. Final Log Set Arrangement Figure 39. Fifth Stage Log Set Installation Figure 38. Fourth Stage Log Set Installation Figure 38: Back end of the front, right of center, log has a hole that rests over the center burner pin (see Figure 34) and the front rest on the ledge...
Page 30 - Remove brick liners, see steps 1 to 4 in
30 Secondary Installation B URNER AND F AN R EMOVAL : 1. Remove brick liners, see steps 1 to 4 in S ECONDARY I NSTALLATION - C ERAMIC B RICK L INER R EMOVAL . 2. The control panel is held in place with a T-20 screw on each end of the panel. Remove the two (2) screws and the control panel. 3. Undo th...
Page 31 - Troubleshooting; Problem
Troubleshooting Problem Possible Cause Solution Spark will not light the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor • Check connections to ignitor. • If ignitor connections are good but no spark, replace ignitor. Broken spark electrode • Check for broken ceramic insula...
Page 32 - Parts List - Components; Reference
32 Parts List - Components Reference Number Description Part Number 1 120°F (49°C) Ceramic Fan Temperature Sensor EC-001 2 S.I.T. Nova Valve NG (50% turn down) EC-006 2 S.I.T. Nova Valve LP (50% turn down) EC-007 3 Thermocouple EC-009 3 Spark Electrode with Ignitor Cable EC-011 3 Thermopile EC-012 3...
Page 33 - Parts Diagram; om
33 Parts Diagram D V5 0D X -C om po ne nt s N ov em be r2 00 4 � �� �� �� �� � � �� � � � �� �� � �� � �� �
Page 35 - Warranty; contaminants
35 Warranty Sherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This Limited Lifetime Warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location.Covered under the life...
Page 36 - Installation Data Sheet
36 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ ___________________...