Page 2 - Safety Precautions
2 FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having j...
Page 3 - Table of Contents
Table of Contents 3 Safety Precautions........................................................................................................2 Table of Contents.........................................................................................................3 Codes And Approvals................
Page 4 - Codes And Approvals
4 DIRECT VENT ONLY: This type is identified by the prefix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. I...
Page 5 - Specifications; INSTALLATION OPTIONS:; • Parallel to a wall or placed in a corner; IMENSIONS; chained to the fireplace.
� � � � � ������� � � � � � ������� � �� � �� � ������� � � � �� � ������ �� � � � � ������� �� � � �� � ������� �� � � �� � ������� �� � � �� � ������� �� � � � � ������� �� � � � � ������� � �� � �� � ������� �� � � � � ������� �� � � �� � ������� �� � � � � ������� � � � � � ������� � � � � � ���...
Page 6 - Operating Instructions; For Your Safety, Read Safety Precautions And; RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.; ILOT; clothing, furniture, gasoline or other flammable vapors away; FOR YOUR SAFETY READ BEFORE
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. P ILOT L IGHTING I NSTRUCTIONS : Figure 2. Lig...
Page 7 - If not recently done, remove the glass and let the unit air out
2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (see ...
Page 8 - TO TURN GAS FIREPLACE OFF:; Component
8 Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating E) Turn on all electrical power to the unit. NOTE: Check that all burner holes are lit. TO TURN GAS FIREPLACE OFF: Flip switch to OFF to turn off burners only.If the fireplace is to be turned...
Page 9 - Maintenance And Service
Maintenance And Service R OUTINE M AINTENANCE : At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame sho...
Page 10 - To avoid this, give the face a quick wipe with
10 Maintenance And Service C LEANING D ECORATIVE S URFACES : Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish a...
Page 11 - TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY; instructions supplied with the kit.; - Installation instruction sheet; URNER; Proceed only when the unit has; Remove the brick panels as shown
11 F UEL C ONVERSION : Maintenance And Service TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all ...
Page 12 - Conversion Kit Installation:
12 Maintenance And Service b) Insert a 5 / 32 ” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 11), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt. d) Flip the screw (refer to Figure 12).e) Using th...
Page 14 - Initial Installation; QUALIFIED INSTALLERS ONLY; NTRODUCTION; no insulating material; nearest perpendicular wall (sidewall to the edge of the opening).
Initial Installation QUALIFIED INSTALLERS ONLY I NTRODUCTION : This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facing, mantels, and venting terminations will be covered, as well as the gas and electric systems. There are several installa...
Page 15 - Mount the two framing mount brackets on each side and secure the; ” for allowable pipe lengths.
Mount the two framing mount brackets on each side and secure the fireplace to framing with screws or nails (refer to Figure 16). The brackets will allow for a 1⁄2” (13 mm), 5⁄8” (16 mm), 3⁄4” (19 mm) thick finishing wall. The wall may be finished up to the fireplace facing with combustible material....
Page 16 - ANTEL
Figure 23. Combustible Mantel Clearances for Fascia or Insets. Initial Installation QUALIFIED INSTALLERS ONLY 16 A shelf may be installed above the unit. We recommend that no heat sensitive items or components be placed on the shelf (see Figure 22). M ANTEL C LEARANCES : It is not necessary to insta...
Page 17 - NOTE: Venting terminals shall not be recessed into walls or siding.; ENT; D E
17 1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the requirements of the gas supplier. t A ven...
Page 18 - it to the inner wall frame using four (4) 11⁄2” wood screws. If a wall is; INSTALLATION INSTRUCTIONS:; IREPLACE
Initial Installation QUALIFIED INSTALLERS ONLY 18 ���� ������� Figure 25: Wire Spacers. it to the inner wall frame using four (4) 11⁄2” wood screws. If a wall is greater than 8” (203mm) in depth, the clearance above the flex must be 43⁄8” (111mm) 6. Apply a bead of Mill-Pac Black sealant to the new ...
Page 19 - THER; Manufacturer
Flue Pipe Adaptor Wall Framing Wall Thimble Fire Stop Exhaust 4" Flex Pipe Combusion Air 6 5 / 8 " Flex Pipe Wire Spacers Horizontal Vent Termination 19 Initial Installation QUALIFIED INSTALLERS ONLY Figure 27: Installation of Fireplace Horizontal Vent Kit. 10. Apply a bead of Mill-Pac Black...
Page 20 - Intertek WH listing of the appliance.
EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the ...
Page 21 - ENTING; WARNING: This gas appliance must not be connected
21 Initial Installation QUALIFIED INSTALLERS ONLY V ENTING : This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” PIPE FOR GAS STOVES, SECURITY CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, AMERICAN METAL PRODUCTS AMERIVENT DIRECT and DIRECT-TEMP SELKIRK ...
Page 22 - except
Figure 31. Possible Vent Configurations for Top Vented; Vertical and Horizontal Terminations. � � � � � Figure 32. Possible Vent Restrictor Positions. Initial Installation QUALIFIED INSTALLERS ONLY V ENT C ONFIGURATIONS AND R ESTRICTOR S ETTINGS : Figures 31 shows the range of venting options, it sh...
Page 23 - ORIZONTAL; the possibility of a fire.
23 Wall framing Horizontal wall termination Wall thimble fire stop Exhaust flex pipe Combustion air outer pipe Elbow Initial Installation QUALIFIED INSTALLERS ONLY H ORIZONTAL T ERMINATION : NOTES:1. Horizontal pipes must not be level. For every 12 inches (305 mm) of horizontal travel (away from the...
Page 24 - ERTICAL
24 Initial Installation QUALIFIED INSTALLERS ONLY Step 3. To install the Round Support Box/Wall Thimble in a flat ceiling, cut a 10 inch (25.4 cm) square hole in the ceiling, centered in the hole drilled in Step 2. Frame the hole as shown in Figure 29. Step 4. Assemble the desired lengths of black p...
Page 25 - corrosion resistance.; Roof Pitch
25 Initial Installation QUALIFIED INSTALLERS ONLY STEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of sufficient size to meet minimum requirements for Clearance to Combustibles, as specified. Continue to assemble lengths of pipe and elbows ne...
Page 27 - Wire Size
Initial Installation QUALIFIED INSTALLERS ONLY I NSTALLATION O F E LECTRICAL W IRING F OR T HE O PTIONAL F AN K IT : Figure 39. Wiring Diagram For Gas Valve. COOL / HEATPROGRAM DOWN UP 70 ° F 70 ° F ON OF F Optional Remote Control ON/OFF/Remote Thermostat Switch Purple Thermocouple Blue Thermopile G...
Page 28 - AS; Always check for gas leaks with a soap; NEVER USE AN OPEN FLAME FOR LEAK TESTING.
28 Initial Installation G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating...
Page 29 - Secondary Installation; OG; NOTE: The logs are fragile and should be handled gently.; back log
29 Figure 41: This is how the fire box looks with only the grate and Optional Brick Panels in place. The burner has three (3) locator pins for the logs. Secondary Installation L OG S ET AND E MBER I NSTALLATION : The placement of the logs is not arbitrary. If they are positioned incorrectly, the fla...
Page 30 - right log
Secondary Installation Figure 44: The right log has two (2) holes in it that will rest over the two (2) locator pins pointed out in Figure 43. Figure 45: The front end of the right/center log has a notch in it that is to rest around the right/center post of the grate. The back end of the log rests o...
Page 31 - Never operate the fireplace with the glass door removed.
31 Secondary Installation Figure 47: Once the logs are in place the embers can be placed onto and around the burner to create a realistic look. Bags of ceramic fiber embers and rock wool are provided. The ceramic fiber comes in chunks that are about 2 inches (5.1 cm) long. Place them irregularly aro...
Page 32 - PTIONAL; Turn off the gas control knob and allow the
32 Secondary Installation O PTIONAL C ERAMIC B RICK P ANEL I NSTALLATION : Turn off the gas control knob and allow the unit to cool. Please ensure that your ceramic panels have not been damaged.To Install Panels:1. Remove the glass door by following the instruction in the “ S ECONDARY I NSTALLATION ...
Page 33 - Fan
Secondary Installation QUALIFIED INSTALLERS ONLY O PTIONAL F AN K IT I NSTALLATION : The optional fan is thermostatically controlled and it will not operate if the appliance is cold. A few minutes after the appliance is lit and the variable speed control is set at a desired setting, the fan will aut...
Page 35 - Trouble Shooting
Trouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for. The gas valve may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degrees above ambient temperature. Problem wit...
Page 36 - Parts List; Reference
Parts List Reference Number Part Description Part Number 1 120°F Ceramic Fan Temperature Sensor EC-001 2 Thermocouple EC-009 2 Spark Electrode with Ignitor Cable EC-011 2 Thermopile EC-012 2 Pilot Orifice NG Threaded EC-019 2 Pilot Orifice LP Threaded EC-020 2 Pilot Gasket EC-021 3 S.I.T. Piezo Igni...
Page 38 - Parts Diagram
38 Parts Diagram � �� � � �� � �� �� � �� � �� �� �� � �� � � �� ��
Page 39 - Warranty; Limited Lifetime Warranty:; exclusions apply to this warranty.; To the Dealer; Sign and verify that work and information are correct.; Exclusions and Limitations:; Limited Warranty does not apply.
39 Warranty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the finest materials...
Page 40 - and as such is not covered under this warranty.
Warranty 4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs of neglect or misuse, it is not covered under the terms of this Warranty policy. Performance problems due to operator error will not be covered by the...
Page 42 - Installation Data Sheet; INSTALLER’S SIGNATURE:
42 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ ___________________...