Page 2 - Table of Contents
2 Introduction...................................................................................................................................3 Rating Label Location................................................................................................................3 Important Safety D...
Page 3 - Introduction; The rating label is located on the back of the unit.; to the installation instructions.; adjusting the slider damper located on the left side of the stove.; Caution: Do not connect to any air distribution duct or system.; damper as needed to ensure proper combustion.
3 Introduction * This manual is designed for the technician in conjunction with the owner’s manual. * R ATING L ABEL L OCATION : The rating label is located on the back of the unit. I MPORTANT S AFETY D ATA : Please read this entire Owner’s Manual before installing or operating this ENVIRO Pellet St...
Page 4 - ELECTRICAL: The use of a surge protected power bar is recommended.; The unit must be; Never; the heater while it is in use.; SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE
4 Introduction ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 220-240 volts,, nominal average 0.8 Amps (1.4 Amps peak), 50 hertz electrical outlet and also must be accessible. If this power ...
Page 5 - Installation
5 Installation D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install the stove in a bedroom. 4. You can...
Page 7 - Install vent at clearances specified by
7 Installation C LEARANCES TO C OMBUSTIBLES : Use a hearth pad that extends 6 inches (15 cm) in front of the unit when installing on a combustible floor. A LCOVE C LEARANCES : This unit may be installed in an alcove. Maintain these clearances to combustibles. Minimum Alcove width 48 inches (122 cm) ...
Page 8 - NOTE: Venting terminals shall not be recessed into walls or siding.
fumes such as stairwells, covered breezeway, etc. 2. Vent surfaces can become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be required. 3. Termination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe be in...
Page 9 - Base of unit to center of flue 103⁄4” (273 mm)
9 Installation E XHAUST L OCATION : 8 3 / 4 " (222mm) 10 3 / 4 " (273mm) Figure 6: Bern Inlet and Outlet Location. Base of unit to center of flue 103⁄4” (273 mm) Side of unit to center of flue 83⁄4” (222 mm) [at center of unit] Figure 7: Corner Installation. C ORNER T HROUGH W ALL I NSTALLAT...
Page 11 - pipe outside the building to help naturally draft in the unit.
11 Installation 10. Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The stainless steel cap termination manufactured by the vent manufacturer is recommended. However, when the vent terminates several feet above ground level and there are no trees...
Page 15 - Do not pass cable
Installation E XTERIOR M OUNTED E XHAUST B LOWER : The Bern can be equipped with an externally mounted exhaust blower. This optional kit includes all components necessary to install the exhaust blower on any vertical wall surface. 1. Remove the left hand cabinet side by removing the two (2) screws d...
Page 16 - blower wiring harness.
Installation T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - H ORIZONTAL T ERMINATION : Electrical Cable Bern 90° Elbow 45°Elbow with Rodent screen or stainless steel termination hood 2ft (610mm) Riser Pipe Adaptor Exterior Blower and Housing Wall Strap To supply power to the ex...
Page 18 - NOTE: NOT FOR USE IN GERMANY
Installation T HERMOSTAT I NSTALLATION : If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to the setting that is displayed on the control board Heat Indi...
Page 19 - technician using magnehelic.
19 If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the Slider Damper should be pushed in slightly, decreasing the air in the firebox.If, after long periods of burning, the fire builds up and overflows the burn pot or there is a build up of clinke...
Page 20 - This kit must be installed before the unit is started.; Installing the Panels:
20 Installation O PTIONAL P ANEL K IT : This kit must be installed before the unit is started. Figure 29: Screws at back of the cab side. Figure 27: Screws above door top corner. Figure 28: Screw behind ash box. Tools Required: ●T-20 screwdriver Kit Components: Quantity Description 1 Left Cab Panel ...
Page 21 - Installing Hopper Lid:
21 Installation 1 2 3 Figure 30: Installing Hopper Lid. Installing Hopper Lid: 1. Attach the hopper brackets to the back of the unit with a screw in each top holes of the brackets (#1 in Figure 30). Do not tighten these screws until all six (6) screws are in place. 2. Lay the hopper lid in place, sl...
Page 22 - Troubleshooting; flash; because the Exhaust Temperature Sensor’s contacts have opened.
Troubleshooting DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. ● Do not remove from the firebox any screws without penetrating oi...
Page 23 - The exhaust motor will not function normally.; (The Vacuum Switch contacts have opened for more than 15 sec.); To reset Circuit Board after a trouble code - push the ON/OFF button
23 Troubleshooting ü Poor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational. ü Exhaust Temperature Sensor failure. – Bypass sensor located on Exhaust Blower if stove now operates properly, the unit may require cleaning or a new sensor. Con...
Page 24 - The convection blower will not function normally.
Troubleshooting 7. The convection blower will not function normally. ü Clean all grill openings at the back and below unit . ü Press the fan button; does the fan come on? Press again to verify that the blower turns on; if, not contact your local dealer for service. 8. Ignitor- the pellets will not l...
Page 25 - Wiring Diagram
25 Wiring Diagram Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White White 115V White 220V Blue White White Orange Orange Orange Orange Yellow Yellow Grey Grey GreyGrey Purple Purple Blue 115V Black 220V Brown Black Black Black Blue Black Black Armor Cable Suppli...
Page 26 - Parts List; Reference
Parts List Reference Number Description Part Number 1 120°F (49°C) Ceramic Fan Temperature Sensor EC-001 2 Auger Motor - 220V EF-001-220V 3 High Limit Temp Sensor 200°F (93°C) Manual Reset EF-016 4 Vacuum Switch - 220V EF-017-220V Silicone Hose EF-018 Aluminum Hose Barb EF-019 Shoulder Bolt, Hardene...
Page 28 - Parts Diagram - Components
Parts Diagram - Components Bern - Components February 2005 � �� �� � �� �� � �� �� � �� �� � �� �� � � � 28
Page 29 - Parts Diagram - Steel; er
29 Parts Diagram - Steel B er n -S te el C om po ne nt s Fe br ua ry 20 05 �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � �� ��
Page 30 - Warranty; ON AN OFFICIAL WARRANTY CLAIM FORM:
Warranty Sherwood Industries Ltd. gives a five year limited warranty on all steel manufactured parts. A one-year warranty is provided on all electrical components. The above limited warranties are extended only to the original purchaser. There is no warranty on the following parts: ● Glass window ● ...
Page 31 - Installation Data Sheet
31 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ NAME OF DEALER: _________________________________________ ADDRE...