Page 2 - Safety Precautions
FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having jur...
Page 3 - Table of Contents
Table of Contents 3 Safety Precautions........................................................................................................2 Table of Contents..........................................................................................................3 Codes And Approvals...............
Page 4 - Codes And Approvals; IN USA
DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. BV: This...
Page 5 - Specifications; chained to the fireplace.
Specifications R ATING L ABEL L OCATION : The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the fireplace. D IMENSIONS : 5 1 11 / 16 " (44mm) 8 1 / 2 " (216mm) 13 7 / 8 " (362mm) 9 7 / 8 " (251mm) 2" (51mm) 7 7 / 1...
Page 7 - Operating Instructions; corner of the unit or with the handset remote control.
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. L IGHTING AND T URNING O FF I NSTRUCTIONS : Figure 3. Lighting instruction label. 1. ARRÊTEZ! Lire les instructions de sécurité mentionnées plus haut. 2....
Page 8 - codes are different for each unit, refer to; Setting the Time; automatically return to the manual mode.; Automatic Pilot Mode:; For fine adjustment tap the up/down arrows.
Operating Instructions The Sonnet is designed to gradually lower or raise the flame as is needed in application. It normally does not just turn on and off. This is very dependant on the size of the room the unit is located in. During the first several operational cycles the electronics go through a ...
Page 9 - Changing the Mode of Operation; and back to; “MAN” Mode - Manual Flame Height Adjustment; confirms transmission with an acoustic signal.; Setting the Temperature
TIMER MODE – (appliance must be in standby mode; pilot ignited): The Timer setting allows you to set two (2) burner times and two (2) burner times every 24 hours. For to operate as a thermostat, TEMP must be set at 40°F (4.5°C) or higher. If the setting is decreased to --, the motor will turn the va...
Page 10 - There is one venturi adjustment. Use this venturi; Component
10 Operating Instructions There is one venturi adjustment. Use this venturi adjustment lever, shown in Figure 7, to achieve a proper and efficient flame. Pull the rod forward for more air or push it in for less air. Adjust lever until the flame pattern is similar to Figure 77. Figure 7: Adjusting th...
Page 11 - Maintenance And Service
Maintenance And Service Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance, may result in property damage or personal injury.At least once a year, run through the following procedures to ensure the system is c...
Page 12 - Never operate the fireplace with the glass
Maintenance And Service G LASS D OOR R EMOVAL : C LEANING T HE P AINTED S URFACES : Painted faces should be wiped with a damp cloth periodically. R EPLACING T HE B ATTERIES : It is recommended that the batteries are replaced at the beginning of each heating season. Batteries must be changed when an ...
Page 14 - TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY; instructions supplied with the kit.
Figure 20: Burner Removal. Figure 19: Unfastening Burner. Maintenance And Service F UEL C ONVERSION : TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in a...
Page 16 - Initial Installation; openings in any way can create hazardous situations.
Initial Installation WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. C LEARANCES TO C OMBUSTIBLES : Maintain sufficient clearances for operation, service and maintenance. • A c...
Page 17 - blockage or severe down draft conditions.
17 Initial Installation Door removed for clarity 1⁄4” Tube B-V ENT M ODEL : WARNING: This appliance has been designed to operate by drawing combustion air and dilution air from the room. It is also designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifyin...
Page 18 - QUALIFIED INSTALLERS ONLY; Quantity Description
Initial Installation QUALIFIED INSTALLERS ONLY at the lower right rear of the unit using locally approved methods. Place the electric cable so it can be connected to the power supply. 7. As you push the unit into its final position in the fireplace, if the vent collar plate was removed, reinstall it...
Page 20 - ENVIRO; A D; must; Minimum Clearance
20 NOTE: If the Sonnet unit is pulled out of its installation, and the vent air intake system is disconnected for any reason, ensure that the vent-air intake pipes are re-sealed with high-temperature sealant or silicone and reconnected with three (3) sheet metal screws evenly spaced. 2ft (0.6m) Mini...
Page 21 - For use with Sonnet Direct Vent Fireplace Insert.; Quantity Description; INSTALLATION INSTRUCTIONS:
�� ����� �� ����� Install sealed throat connector or flashing to prevent leakage of room air up through chimney. DV Only: Before installing vent liners, mark each liner on both ends to designate which is the intake and the exhaust. Measure the height of the chimney beforehand and purchase the approp...
Page 24 - ● 1⁄4” Socket or Driver or Flat Head Screwdriver
Initial Installation QUALIFIED INSTALLERS ONLY E LECTRICAL R EQUIREMENTS : The fan will not operate if the appliance is cold. A few minutes after the appliance is lit and the fan is set to low or high, the fan will automatically turn on. The fan will automatically turn off after the appliance has co...
Page 25 - Quantity
25 4. Hold the back panel close to the left side of the unit and hook the two (2) slots on the fan bracket over the rubber grommets found on the inside of the back panel (see Figure 50). 5. Ground the power cord to the unit using a star washer and T-20 screw (see Figure 51). 6. Slide the fan switch ...
Page 26 - exceeds
G AS L INE C ONNECTION : an access hole of 1.5 in (37.5mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be plugged with non-combustible insulation after the gas supply line has been installed.” • A shut-off valve i...
Page 27 - TO TEST VALVE PRESSURES:; , log set and ember; Main Burner; NEVER USE AN OPEN FLAME FOR LEAK TESTING.
27 TO TEST VALVE PRESSURES: The pressure taps are located on the front side of the valve (see Figure 54 & 55).1. Remove the door (refer to M AINTENANCE AND S ERVICE - G LASS D OOR R EMOVAL ) , log set and ember material, brick panels, burner tray, and the valve cover to access the valve (refer t...
Page 28 - Secondary Installation; Colonial or Classic Trim; Adjustable Surround
28 Secondary Installation O PTIONAL B ASE S HELF & R ISER : The Sonnet Base Shelf (15⁄8” (41 mm) high) and Base Shelf Riser (21⁄8” (54 mm) high) are black powder coated components that can be combined to create a riser with an overall height of 2 3 / 16 ” (55 mm). This shelf can be installed wit...
Page 33 - NOTE: The logs are fragile and should be handled gently.; back left log
33 Secondary Installation L OG S ET AND E MBER I NSTALLATION : NOTE: The logs are fragile and should be handled gently. Figure 70. Empty firebox. Figure 71. First Stage Log Set Installation. Figure 72. Second Stage Log Set Installation. Figure 71: The back left log rests behind the left ledge pointe...
Page 34 - right log
Secondary Installation Figure 73. Third Stage Log Set Installation. Figure 75. Fifth Stage Log Set Installation. Figure 74. Fourth Stage Log Set Installation. Figure 73: The center of the right log fits onto the locator pin on the back right log (see Figure 72). The front of the log is to rest on th...
Page 35 - ports air holes are blocked.; Never operate the fireplace with the glass door removed.
35 Secondary Installation Figure 77. Sonnet complete log set-up with embers burning. NOTE: While the glass is still removed, it is recommended that the gas line be purged by lighting the pilot.When lighting the fireplace for the first time since the log set and embers have been installed/replaced, w...
Page 36 - Trouble Shooting; Problem
Trouble Shooting Problem Possible Cause Solution No transmissions; remote control doesn’t work. Receiver must learn new code. • Reset the receiver’s code, refer to M AINTENANCE A ND S ERVICE - C HANGING R EMOTE H ANDSET C ODE . One or more of the batteries are dead. • Replace the batteries, refer to...
Page 38 - Parts List - Components
Trouble Shooting Problem Possible Cause Solution 3 short beeps while motor turns. One or more of the batteries are low. • Replace the batteries, refer to M AINTENANCE A ND S ERVICE - R EPLACING T HE B ATTERIES . W ARNING : Creating an electrical short between the batteries/battery box and metal part...
Page 39 - Reference
Parts List - Components 39 Reference Number Part Description Part Number 9 Large Ember Nuggets Only 50-832 10 Ceramic Wool Embers Only 50-893 11 Sonnet Log set 50-1420 12 Sonnet Conversion Kit LP to NG Maxitrol 50-1445 12 Sonnet Conversion Kit NG to LP Maxitrol 50-1446 13 Maxitrol Remote Control 50-...
Page 40 - Parts Diagram - Components; SO
Parts Diagram - Components SO N N ET -C om po ne nts Se pte m be r2 00 6 � � � �� � � � � �� �� �� �� � � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� 40
Page 41 - Parts Diagram - Options
41 Parts Diagram - Options SONNET - Options September 2006 �� �� �� �� �� �� �� �� �� Parts List - Options Reference Number Option Description Part Number 42 Sonnet Surround Adjustable 50-1414 43 Sonnet Surround Trimmable 50-1415 44 Sonnet Cast Andiron & Grate 50-1417 45 Sonnet Fan Kit 50-1418 4...
Page 42 - Warranty; Limited Lifetime Warranty:; To the Dealer
Warranty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the finest materials an...
Page 44 - Installation Data Sheet
44 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ ___________________...