Page 2 - Safety Precautions
2 FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having j...
Page 3 - Table of Contents
Table of Contents 3 Safety Precautions.....................................................................................................2 Table of Contents......................................................................................................3 Codes And Approvals......................
Page 4 - Codes And Approvals
4 DIRECT VENT ONLY: This type is identified by the sufix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. TOP VENT DV Certified for installation from 0-4500 ft (0-1372 m) REAR VENT DV Certified for installation from 0-45...
Page 5 - Specifications; Note: When installing on a carpeted surfaces a non-
5 Specifications WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. D IMENSIONS : 16 5 / 8 " (42.2cm) 25 3⁄4" (65.3cm) 25 3⁄4" (65.4cm) 27" (68.6cm) 25 3⁄4" (6...
Page 6 - Operating Instructions; For Your Safety, Read Safety Precautions And; RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.; TIO
6 Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. P ILOT L IGHTING I NSTRUCTIONS : Figure 3. L...
Page 7 - If not recently done, remove the glass and let the unit air
7 2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (se...
Page 8 - Maintenance And Service; When the fireplace has cooled
8 Electronic ignition module Maintenance And Service R OUTINE M AINTENANCE : At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by ...
Page 9 - replacement is required (see; ). Wear gloves when handling damaged glass door; must; be done by a licensed or; The glass must be purchased from an ENVIRO dealer. No substitute; the tape in a bottom corner. Close door.
Figure 7: Handles for Removing Door. Figure 8: Removing of Door. Maintenance And Service R EPLACING THE G LASS : The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see P ARTS L IST - C OMPONENTS ). Wear gloves when handlin...
Page 10 - TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY; manufacturer’s instructions supplied with the kit.
Maintenance And Service TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY F UEL C ONVERSION : Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdicti...
Page 12 - NOTE: Venting terminals shall not be recessed into walls or siding.; Initial Installation; QUALIFIED INSTALLERS ONLY; D E
12 1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the requirements of the gas supplier. t A ven...
Page 13 - length of vent pipe for the particular requirements.; FOLLOW THE VENT LENGTH DIAGRAM PRECISELY.
13 Initial Installation QUALIFIED INSTALLERS ONLY V ENT P ARTS : This fireplace have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SELKIRK DIRECT-TEMP SYSTEM SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS MDV VENT SYSTEM” kits are ...
Page 14 - ENVIRO
1 2 3 4 5 ���� ������� ����� ���� ���������� ����� ���� ������� ����� ������ ���������� ����� 1 2 3 4 5 Figure 11: Restrictor plate settings. Initial Installation QUALIFIED INSTALLERS ONLY Figure 12. Possible Vent Configurations for Top Vented; Vertical and Horizontal Terminations. The ENVIRO WESTPO...
Page 16 - location of the appliance.
Initial Installation QUALIFIED INSTALLERS ONLY H ORIZONTAL I NSTALLATION : STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance...
Page 18 - should have a 1⁄4 inch rise for every one foot; Never allow the vent to run downward. This could cause high
18 NOTES: (1) The four (4) wood screws provided should be replaced with the appropriate fasteners for stucco, brick, concrete, or other types of siding. (2) For buildings with vinyl siding, a vinyl siding standoff, should be installed between the vent cap and the exterior wall (see Figure 19). Attac...
Page 19 - STEP 2
STEP 3. To install the Round Support Box/Wall Thimble in a flat ceiling, cut a 10” square hole in the ceiling, centered in the hole drilled in Step 2. Frame the hole as shown in Figure 23. STEP 4 . Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up...
Page 21 - Follow installation steps 1 & 2 under; outline of the “Cathedral Ceiling Support Box”.
21 (2) Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passes through, must be enclosed. The enclosure may be framed and sheet rocked with standard building materials. However consult the appliance manufactures installation instructions for the...
Page 22 - Quantity; INSTALLATION INSTRUCTIONS:
Figure 28: Cathedral Ceiling Support Box Leveling. Figure 29: Cathedral Ceiling Support Box Installation. STEP 6. Complete the cathedral ceiling installation by following the same procedures outlined in Steps 4 through 9 for I NITIAL I NSTALLATION - V ERTICAL I NSTALLATION . F REESTANDING D IRECT V ...
Page 23 - Do not slip the
23 3. Set the appliance in the desired location. Temporarily place a 24” (61 cm) section with the non- crimped end on the unit 4. Install the 90° elbow onto the vertical pipe on the stove pointing in the direction that the vent will exit the structure. 5. Project a level line from the center point o...
Page 25 - ‘A’ C
25 Initial Installation QUALIFIED INSTALLERS ONLY V ENTING INTO A C LASS ‘A’ C HIMNEY : This model is also certified and tested to vent into CLASS ‘A’ wood stove chimneys.Place the freestanding direct vent appliance in the desired location.Use a conversion kit from Simpson Duravent (931, 932, or 933...
Page 30 - AUTOMATIC SAFETY SHUT DOWN:
30 Initial Installation 4. After a minimum of 10 minutes operation, test the chimney draft with a smoke match at the top row of the pattern to confirm that there is adequate draft or ‘pull’ at the openings around the body of the Drafthood Adaptor, as shown in Figure 42. AUTOMATIC SAFETY SHUT DOWN: I...
Page 31 - required pressure test.; NEVER USE AN OPEN FLAME FOR LEAK TESTING.
31 Initial Installation QUALIFIED INSTALLERS ONLY G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. O L I T P TP TH TP TH IN OU T H I LO N OF O F LI P T O Manifold Pressure Tap Inlet Pressure Tap Hi/...
Page 32 - The; Wire Size; DO NOT; cut or remove the grounding prong from this plug.
32 Figure 45: Gas Control Valve and Optional Thermostat Wiring. Initial Installation QUALIFIED INSTALLERS ONLY E LECTRICAL R EQUIREMENTS F OR G AS V ALVE AND O PTIONAL B LOWER : The ENVIRO WESTPORT will operate without electrical power. This model has a millivolt gas control, which uses the pilot fl...
Page 33 - Secondary Installation; NOTE: The logs are fragile and
Fan assembly Valve cover Control panel (Fan control location) Screw hole Figure 47: Optional Blower (Fan) Installation. Secondary Installation I NSTALLATION OF O PTIONAL B LOWER : 1. Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage is noticed call your dea...
Page 34 - ALL
34 1. Carefully remove logs from box. Check to ensure there is no damage. It is very important to install all logs in their proper position to insure safe, optimum operating conditions. 2. Place the log set into the firebox. Locate each log by seating it down onto the burner tray support pins. Follo...
Page 35 - CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED.
Secondary Installation CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED. Important note: When the unit is turned on for the first time, It should be turned onto high without the fan on for the first four (4) hours. This will cure the paint, logs, gasket material and the other produc...
Page 36 - Do not install when the unit is hot.
36 Figure 57: Top brick panel in place, screws shown. Figure 58: Back brick panel in place. Figure 59: Side brick panels in place. Figure 56: Brick panel bracket, slots shown. 1. Remove the two (2) screws from the rear of the baffle, use a 1⁄4” socket or a flat head screwdriver. Place the provided b...
Page 37 - Trouble Shooting; Problem
Trouble Shooting Problem Possible Cause Solution Spark will not light the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor. • Check connections to ignitor. • If ignitor connections are good but no spark, replace ignitor. Broken spark electrode. • Check for broken ceramic ins...
Page 41 - Parts List - Components; Reference
41 Parts List - Components Reference Number Part Description Part Number 9 120° Ceramic Fan Temperature Sensor EC-001 10 S.I.T. Nova Valve NG (50% Turn Down) EC-006 10 S.I.T. Nova Valve LP (50% Turn Down) EC-007 11 Thermocouple EC-009 11 Spark Electrode with Ignitor Cable EC-011 11 Thermopile EC-012...
Page 43 - Parts Diagram - Components; WESTPORT - Components
43 Parts Diagram - Components �� �� �� �� �� �� �� �� � �� �� �� �� �� �� �� �� �� �� �� �� WESTPORT - Components January 2005
Page 44 - Warranty; The following exclusions apply:; When filing a warranty claim please; TO THE DEALER; Sign and verify that work and information are correct.
Warranty Sherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This limited lifetime warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location Covered under the lifetim...
Page 45 - Installation Data Sheet; INSTALLER’S SIGNATURE:
45 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ ___________________...