Page 2 - Table of Contents
Table of Contents 2 Introduction..............................................................................................................3 Pellet Quality..................................................................................................3 Rating Label Location........................
Page 3 - PELLET QUALITY IS IMPORTANT, PLEASE READ; Introduction; ELLET
PELLET QUALITY IS IMPORTANT, PLEASE READ YOUR ENVIRO PELLET STOVE HAS BEEN DESIGNED TO BURN WOOD PELLETS ONLY. DO NOT USE ANY OTHER TYPE OF FUEL, AS THIS WILL VOID ANY WARRANTIES STATED IN THIS MANUAL. CAUTION: It is important to select and use only pellets that are dry and free of dirt or any impur...
Page 4 - Fuel; THE USE OF CORDWOOD IS PROHIBITED BY LAW.; THE USE OF A SURGE PROTECTED POWER BAR IS RECOMMENDED.; THIS ENTIRE OWNER’S MANUAL BEFORE INSTALLING OR OPERATING YOUR; An ENVIRO dealer will be happy to assist you.; PRESSURE AND A SLIGHTLY POSITIVE CHIMNEY PRESSURE.; IT IS VERY IMPORTANT TO ENSURE THAT THE EXHAUST; The rating label is located on the inside of the hopper lid.
Fuel : T his pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty fuel will adversely affect the operation and performance of the unit and may void the warranty. Check with your dealer for fuel recommendations. THE USE OF CORDWOOD IS PROHIBITED BY LAW....
Page 5 - KEEP ASH PAN FREE OF RAW FUEL.; OF YOUR STOVE, SHERWOOD INDUSTRIES LTD. GRANTS NO WARRANTY IMPLIED; SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE
Glass: Do not abuse the glass by striking or slamming the door. Do not attempt to operate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO dealer. Do not attempt to open the door and clean the glass while the unit is in operation or if gla...
Page 6 - TOVE; Operating Instructions
Your pellet Stove has the following safety features: A) The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F (49°C). B) The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F (93°C) the auger will automatically stop, and...
Page 7 - This stove can be placed into two different thermostat modes:; HERMOSTAT
7 This stove can be placed into two different thermostat modes: HI / LOW OPERATION: If the unit has been placed in the HI / LOW mode. The unit will operate on the low setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to your selected setting wh...
Page 8 - LIDER; THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION.
8 Operating Instructions S LIDER /D AMPER S ETTING : The slider damper is located behind the left cab side. The door must be open for the cab side to be removed on all models. On freestanding model loosen the two T20 torx screws, one above and one below hinge, swing open left panel to access. On ins...
Page 9 - DO NOT unplug unit while Combustion fan is operating.
PRE-BURN INSTRUCTIONS : The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit. DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN AJAR MANUAL MODE: To START: Press the ON / OFF Button...
Page 10 - Routine Cleaning and Maintenance; ASH PAN AND DOOR GASKETS
10 2-3 DAYS/WEEKLY SEASON or 2 TONS OF FUEL Burn Pot and Liner Exhaust Vent Ash Pan Fresh air Intake Tube Inside Firebox Blower Mechanisms Door Glass Heat exchanger tubes Heat exchanger tubes Behind firebox liners Ash pan and Door gaskets All Hinges Door Latch Post Season Clean-up TOOLS REQUIRED TO ...
Page 12 - Installation
1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, garage, or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install the stove in a bedroom. 4. You can vent the stove through an exterior wall behind the unit or connect ...
Page 13 - REESTANDING; LOOR
13 Installation F REESTANDING D IMENSIONS : WIDTH: 24 7⁄8 inches (63.2 cm) HEIGHT: 32 1⁄2 inches (82.6 cm) DEPTH: 24 3⁄4 inches (63.2 cm) ����� ��� ����� ��� ����� ��� ����� ��� Your MERIDIAN pellet stove requires floor protection. The floor protection must be non-combustible, extending beneath the ...
Page 15 - ENT
1. Do not terminate the vent in any enclosed or semi-enclosed areas such as a carport, garage, attic, crawlspace, narrow walkway, closely fenced area, under a sundeck or porch, or any location that can build up a concentration of fumes such as stairwells, covered breezeway, etc. 2. Vent surfaces can...
Page 16 - WARNING: DO NOT INSTALL IN A ROOM
Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes. When connecting to an outside fresh air source, do not use plastic, combustible pipe. Only 2” ID (inside diameter) steel, aluminum or copper pipe should be used. It is recommended, when you are installing a ...
Page 17 - HROUGH
17 The MERIDIAN can be vented through the wall using two different methods. Only use vent of (L or PL) type with an inside diameter of 3 or 4 inches (7.6 or 10.1 cm) VENT INSTALLATION: INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. A chimney connector shall not pass through an attic ...
Page 19 - ERTICAL
19 1. Choose a stove location that is ideal. See the section Deciding Where to Locate Your Pellet Appliance. 2. Place the unit on the hearth pad (if installed on a carpeted surface) and space the unit in a manner so when the pellet vent is installed vertically, it will be 3” (7.6 cm) away from a com...
Page 20 - EARTH
1. Lock fireplace damper in the open position. 2. Install positive flue connector at the fireplace dampers. 3. Connect a Tee or a 90 ° degree elbow to the exhaust pipe. 4. Install flexible stainless steel liner or listed pellet vent to the top of the chimney. Installation H EARTH M OUNT I NSTALLATIO...
Page 21 - INCLUDED IN THE EXTERIOR MOUNTED EXHAUST BLOWER KIT ARE:; XTERIOR
The MERIDIAN can be equipped with an externally mounted exhaust blower (PART #20-070). This optional kit will include all components necessary to install the exhaust blower on any external vertical wall surface. Choose a location for your stove that meets the requirements stated in this manual and a...
Page 22 - Wall framing
22 Installation E XTERIOR M OUNTED E XHAUST B LOWER : TO SUPPLY POWER TO THE EXHAUST BLOWER: Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble, and attach to the pre-drilled hole in the left hand rear hopper pillar. Hook up to wires from the wiring ha...
Page 24 - ASONRY
24 Installation M ASONRY F IREPLACE I NSERT I NSTALLATION : The Fireplace insert model requires a surround faceplate and a pedestal. When installing this unit, ensure that the pedestal is removed from the inside of the hopper and installed on the bottom of the unit (see “Installation of Fireplace In...
Page 27 - LATED
27 Installation P LATED T RIM I NSTALLATION : TO AVOID PERSONAL INJURY DO NOT REMOVE OR REPLACE TRIMS WHEN PELLET STOVE IS HOT! KIT COMPONENTS: TOOLS REQUIRED: ●T20 screwdriver ● 11 / 32 ” socket REMOVAL OF SIDE TRIMS: When stove is off and cool, open the door. Remove the two screws on the right cab...
Page 29 - Troubleshooting
29 DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. ● Do not remove from the firebox any screws without penetrating oil lubrication...
Page 30 - To reset Circuit Board after a trouble code - push the ON/OFF button
30 ü Check the Exhaust Blower voltage across the blower wires (>=114V on #5 setting and >= 82V on #1 setting). – Replace the Circuit Board if the Voltage reading is less than 82V. with a line voltage >115Vac. ü Check Vacuum levels in the exhaust channel by bypassing the Vacuum Switch, then ...
Page 32 - Wiring Diagram
Page 33 - Parts List
33 Parts List Part Number Description 20-040 Control Panel Door 50-178 Circuit Board 115V 50-179 Circuit Board Decal - 115V 50-323 Control Panel Touch Latch 50-330 Circuit Board Control Panel 50-473 Combustion/ Exhaust Blower - 115V 50-474 Stainless Steel Burn Pot Liner 50-683 Door Cover - Painted 5...
Page 34 - Parts Diagram - Freestanding Steel
34 M ER ID IA N Ste el Pa rts ba sed on Fr ees tan din g � �� � � �� �� �� H op pe rlid ha nd le 50 -5 23 Fre es ta nd in g ba ck gril l 50 -6 75 To p trim P ain te d 50 -6 71 G old 50 -6 72 P ew te r 50 -6 73 A ntiq ue co pp er 50 -6 74 Fre es ta nd in g ho pp er lid 50 -6 76 Fre es ta nd in g to p...
Page 35 - Parts Diagram - Insert Steel; ER
35 Parts Diagram - Insert Steel M ER ID IA N St ee lP ar ts ba se d on In se rt � �� � � �� �� �� To p tri m P ai nt ed 50 -6 71 G ol d 50 -6 72 P ew te r 50 -6 73 A nt iq ue co pp er 50 -6 74 In se rt ho pp er lid 50 -8 27 In se rt to p fro nt 50 -8 25 In se rt ca bi ne t si de rig ht 50 -8 24 In s...
Page 36 - Parts Diagram - Components
36 M ER ID IA N C O M PO N E N T S � �� � � �� �� �� 20 0° F (9 3° C )m an ua lre se t hig h lim it se ns or EF -0 16 C on ve ctio n blo w er -1 15 V EF -0 02 C irc uit bo ard -1 15 V 50 -1 78 A ug er EF -0 25 B ra ss au ge rb us hin g EF -0 65 A ug er m oto r- 11 5V EF -0 01 V ac uu m sw itc h -1 1...
Page 37 - Warranty
Sherwood Industries Ltd. gives a five year limited warranty on all steel manufactured parts. A one-year warranty is provided on all electrical components. The above limited warranties are extended only to the original purchaser. There is no warranty on the following parts: ● Fiberglass rope baskets ...
Page 38 - Installation Data Sheet
38 The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ P...