Page 2 - SAFETY PRECAUTIONS; GENERAL; Installation and repair should be done by a
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" ROOM HEATER, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: • All "ENVIROGAS" gas-fired appliances must be installed in accordance with these instructions. Carefully read all the instructions in this manual...
Page 3 - TABLE OF CONTENTS; ENVIROGAS 828 VENTED ROOM HEATER
TABLE OF CONTENTS 1 Code Approvals ................................................................................................................................... 3 2 Specifications .....................................................................................................................
Page 4 - FIREPLACE INSERT CLEARANCES TO COMBUSTIBLES:; FREESTANDING CLEARANCES TO COMBUSTIBLES:
FOR INSTALLATIONS ABOVE 2000 FEET • In Canada, these appliances are certified for altitudes of 0-2,000 feet and must be derated by 10% for installation at elevations between 2,000 and 4,500 feet. • In the USA, these appliance are certified for elevations up to 2,000 feet. For elevations above 2,000 ...
Page 5 - DECIDING WHERE TO LOCATE YOUR FREESTANDING STOVE; PRIMARY INSTALLATION
4. DECIDING WHERE TO LOCATE YOUR FREESTANDING STOVE 1. The stove should be located out of traffic and away from furniture and draperies. 2. This stove should have sufficient access for its safe operation and maintenance. 3. Locate a position where the flue system of the stove can be properly install...
Page 6 - ASSEMBLY AND INSTALLATION INSTRUCTIONS; PREPARATION FOR INSTALLATION; ASSEMBLING AND INSTALLING YOUR ENVIROGAS
* As specified in CGA B149 Installation Codes (1991) Note: Local Codes or Regulations may require different clearances. 5. ASSEMBLY AND INSTALLATION INSTRUCTIONS PREPARATION FOR INSTALLATION • Remove the packaging from the appliance, pedestal or surround panels, check to make sure there is no damage...
Page 7 - ASSEMBLING YOUR ENVIROGAS 828 FREESTANDING APPLIANCE
13. Re-attach the hinged side flaps by sandwiching the surround panels between the mounting brackets and the hinged side flaps. secure with screws. 14. Re-install the stove top by inserting the locating screws, previously put into the surround panel top, through the holes in the back of the stove to...
Page 8 - ELECTRICAL REQUIREMENTS
6. ELECTRICAL REQUIREMENTS The ENVIROGAS 828 Series will operate without an external electrical power supply. This model has a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burners. CAUTION: Label all wires prior to disconnection when servicing c...
Page 9 - GAS LINE CONNECTION AND TESTING; TO TEST VALVE PRESSURES; NEVER USE OPEN FLAME FOR LEAK TESTING
7. GAS LINE CONNECTION AND TESTING WARNING: Only persons licensed to work with gas piping can make the gas connections to this appliance. This appliance is equipped with a 3/8” stainless steel flex line from the valve. This line may be routed through the hole in the rear of the pedestal, or on inser...
Page 10 - AUTOMATIC FLUE GAS SPILL SWITCH; A. VENTING FIREPLACE INSERTS
8. VENTING WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AIR FROM THE ROOM. IT IS ALSO DESIGNED TO DRAW ROOM AIR FOR PROPER HEAT CIRCULATION FROM THE SIDES OF THE UNIT. BLOCKING OR MODIFYING THE LOUVERS IN ANY WAY CAN CREATE HAZARDOUS SITUATIONS, EITHER ...
Page 11 - B. VENTING FREESTANDING MODELS
constructed out of non-combustible materials. Make sure that all chimney clean outs are tightly fitting and will not permit air to leak into the chimney. Remove the vent collar plate from the top of the insert and connect it securely with at least 3 sheet metal screws and a 4" hose clamp. Check ...
Page 12 - AIR SHUTTER ADJUSTMENT
For best venting performance, we recommend total vent height of 10ft (3m) to 30ft (9m). Total horizontal length depends on the number of elbows used. The venting should never slope down. 1/4" rise per 2' horizontal is recommended. If practical, it is best have shorter horizontals and fewer elbow...
Page 13 - INSTALLATION OF LOG SET and EMBERS; A. INSTALLING THE GLOWING EMBERS; CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED
10. INSTALLATION OF LOG SET and EMBERS A. INSTALLING THE GLOWING EMBERS A bag of ceramic fiber embers is provided for use on the front burner tray. CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than requir...
Page 14 - OPERATING INSTRUCTIONS
11. OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot which must be lit by hand by following these ...
Page 15 - ROUTINE MAINTENANCE; TO REPLACE DOOR AND GLASS ASSEMBLY; LUBRICATING THE BLOWER
12. ROUTINE MAINTENANCE Periodically check to ensure that the "B-Vent" venting system is clear and that a negative draft is present when the unit is operating. On fireplace insert models there is a draft inspection tube the opening is located on the right hand side behind the hinged side. A ...
Page 16 - TROUBLE SHOOTING
13. TROUBLE SHOOTING Problem Possible Cause Solution Spark will not arc to the pilot after repeated pressing of spark ignitor Defective piezo ignitor Check connections to ignitor -If ignitor connections are good but there is no spark-replace ignitor Broken spark electrode -Check for broken ceramic i...
Page 17 - PARTS AND ACCESSORIES; Service Parts available from your local ENVIROGAS Dealer.
14. PARTS AND ACCESSORIES Service Parts available from your local ENVIROGAS Dealer. PART # DESCRIPTION 828-001 Convection Blower 828-002 Heyco Strain Relief 828-003 2-Speed Fan Switch 828-004 Eurosit Manually Regulated Valve, Natural Gas 828-005 Eurosit Manually Regulated Valve, Liquid Propane 828-0...
Page 18 - ON AN OFFICIAL WARRANTY CLAIM FORM:
18 15. WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifetime warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location Covered under the lifetime warrant...
Page 19 - INSTALLATION DATA SHEET
16. INSTALLATION DATA SHEET The following information must be recorded by the installer for warranty purposes and future reference. Envirogas Model: EG-828 INSERT BV. FPI Name of Owner: __________________________________________ Address: __________________________________________ ___________________...