Page 2 - Safety Precautions
2 FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having j...
Page 3 - Table of Contents
Table of Contents 3 Safety Precautions.....................................................................................................2 Table of Contents......................................................................................................3 Codes And Approvals......................
Page 4 - Codes And Approvals
4 DIRECT VENT ONLY: This type is identified by the prefix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. I...
Page 5 - Specifications; INSTALLATION OPTIONS:; • Parallel to a wall or placed in a corner; chained to the fireplace.
� � � � � ������� � � � � � ������� � �� � �� � ������� � � � �� � ������ �� � � � � ������� �� � � �� � ������� �� � � �� � ������� �� � � �� � ������� �� � � � � ������� �� � � � � ������� � �� � �� � ������� �� � � � � ������� �� � � �� � ������� �� � � � � ������� � � � � � ������� � � � � � ���...
Page 6 - Operating Instructions; For Your Safety, Read Safety Precautions And; RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. P ILOT L IGHTING I NSTRUCTIONS : Figure 2. Lig...
Page 7 - If not recently done, remove the glass and let the unit air
2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (see ...
Page 8 - TO TURN GAS FIREPLACE OFF:
8 Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating E) Turn on all electrical power to the unit. NOTE: Check that all burner holes are lit. TO TURN GAS FIREPLACE OFF: Flip switch to OFF to turn off burners only.If the fireplace is to be turned...
Page 9 - Maintenance And Service
Maintenance And Service R OUTINE M AINTENANCE : At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame sho...
Page 10 - To avoid this, give the face a quick wipe with
10 Maintenance And Service C LEANING D ECORATIVE S URFACES : Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish a...
Page 11 - TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY
11 F UEL C ONVERSION : Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a ...
Page 12 - Initial Installation; QUALIFIED INSTALLERS ONLY; no insulating material; nearest perpendicular wall (sidewall to the edge of the opening).
Initial Installation QUALIFIED INSTALLERS ONLY I NTRODUCTION : This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facing, mantles, and venting terminations will be covered, as well as the gas and electric systems. There are several installa...
Page 13 - ” for allowable pipe lengths.
Mount the two framing mount brackets on each side and secure the fireplace to framing with screws or nails (refer to Figure 7). The brackets will allow for a 1⁄2” (13 mm), 5⁄8” (16 mm), 3⁄4” (19 mm) thick finishing wall. The wall may be finished up to the fireplace facing with combustible material. ...
Page 15 - NOTE: Venting terminals shall not be recessed into walls or siding.; D E
15 1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the requirements of the gas supplier. t A ven...
Page 16 - must comply with local building codes.
16 Initial Installation QUALIFIED INSTALLERS ONLY V ENT P ARTS AND T ERMINAL C LEARANCES : The Sherwood Home Collection of fireplaces have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS...
Page 18 - except
Figure 23. Possible Vent Configurations for Top Vented; Vertical and Horizontal Terminations. � � � � � Figure 24. Possible Vent Restrictor Positions. Initial Installation QUALIFIED INSTALLERS ONLY V ENT C ONFIGURATIONS AND R ESTRICTOR S ETTINGS : Figures 23 shows the range of venting options, it sh...
Page 19 - the possibility of a fire.
19 Wall framing Horizontal wall termination Wall thimble fire stop Exhaust flex pipe Combustion air outer pipe Elbow Initial Installation QUALIFIED INSTALLERS ONLY H ORIZONTAL T ERMINATION : NOTES:1. Horizontal pipes must not be level. For every 12 inches (305 mm) of horizontal travel (away from the...
Page 21 - corrosion resistance.; Roof Pitch
21 Initial Installation QUALIFIED INSTALLERS ONLY STEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of sufficient size to meet minimum requirements for Clearance to Combustibles, as specified. Continue to assemble lengths of pipe and elbows ne...
Page 24 - Always check for gas leaks with a soap; NEVER USE AN OPEN FLAME FOR LEAK TESTING.
24 Initial Installation G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating...
Page 25 - Secondary Installation; NOTE: The logs are fragile and should be handled gently.; back log
25 Figure 33: This is how the fire box looks with only the grate and Optional Brick Panels in place. The burner has three (3) locator pins for the logs. Secondary Installation L OG S ET AND E MBER I NSTALLATION : The placement of the logs is not arbitrary. If they are positioned incorrectly, the fla...
Page 26 - right log
Secondary Installation Figure 36: The right log has two (2) holes in it that will rest over the two (2) locator pins pointed out in Figure 35. Figure 37: The front end of the right/center log has a notch in it that is to rest around the right/ center post of the grate. The back end of the log rests ...
Page 27 - Never operate the fireplace with the glass door removed.
27 Secondary Installation Figure 39: Once the logs are in place the embers can be placed onto and around the burner to create a realistic look. Bags of ceramic fiber embers and rock wool are provided. The ceramic fiber comes in chunks that are about 2 inches (5.1 cm) long. Place them irregularly aro...
Page 28 - Turn off the gas control knob and allow the
28 Secondary Installation O PTIONAL C ERAMIC B RICK P ANEL I NSTALLATION : Turn off the gas control knob and allow the unit to cool. Please ensure that your ceramic panels have not been damaged.To Install Panels:1. Remove the glass door by following the instruction in the “ S ECONDARY I NSTALLATION ...
Page 31 - Trouble Shooting; Problem
Trouble Shooting Problem Possible Cause Solution Spark will not light the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor • Check connections to ignitor. • If ignitor connections are good but no spark, replace ignitor. Broken spark electrode • Check for broken ceramic insul...
Page 32 - Parts List; Reference
Parts List Reference Number Part Description Part Number 1 120°F Ceramic Fan Temperature Sensor EC-001 2 S.I.T. Nova Valve NG (50% turn down) EC-006 2 S.I.T. Nova Valve LP (50% turn down) EC-007 3 Thermocouple EC-009 3 Spark Electrode with Ignitor Cable EC-011 3 Thermopile EC-012 3 Pilot Orifice NG ...
Page 33 - Parts Diagram
33 Parts Diagram � �� � � �� � �� �� � � � �� �� �� � �� �� � �� ��
Page 34 - Warranty; When filing a warranty claim please
Warranty Sherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This Limited Lifetime Warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location.Covered under the lifetim...
Page 35 - Installation Data Sheet
35 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ ___________________...