2 FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having j...
Page 3 - Table of Contents
Table of Contents 3 Safety Precautions......................................................................................................2 Table of Contents.......................................................................................................3 Codes And Approvals....................
Page 4 - Codes And Approvals
4 DIRECT VENT ONLY: This type is identified by the prefix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. I...
Page 5 - Specifications; INSTALLATION OPTIONS:; • Parallel to a wall or placed in a corner; chained to the fireplace.
Specifications INSTALLATION OPTIONS: • Parallel to a wall or placed in a corner • With a floor hearth or raised up the wall • Ducting to other rooms • Vertical or horizontal venting WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result ...
Page 6 - Operating Instructions
6 WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. P iLot L ighting i nstRuctions : Figure 2. Lighting instruction label. CAUTION: Hot while operating. Do not touch. Severe burns may result. Keep childr...
Page 7 - NEVER USE AN OPEN FLAME FOR LEAK TESTING; If not recently done, remove the glass and let the unit air out
Warning: Incorrect venturi adjustment may lead to improper combustion, which is a safety hazard. Contact the dealer if there is any concern about the venturi adjustment. NEVER USE AN OPEN FLAME FOR LEAK TESTING a iR D iveRteR c ontRoL : When the blower is on, the amount of air flow into the room can...
Page 8 - TO TURN GAS FIREPLACE OFF; Component
Operating Instructions b uRneR L ighting : A) Make sure the pilot is lit. B) Turn gas control knob COUNTER CLOCKWISE to ON. C) Flip the burner switch to ON. D) Turn HI/LO knob to the desired flame height. E) Turn on all electrical power to the unit. NOTE: Check that all burner holes are lit. TO TURN...
Page 9 - Maintenance And Service
9 Maintenance And Service R outine m aintenance : At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame s...
Page 10 - To avoid this, give the face a quick wipe with
Maintenance And Service c Leaning D ecoRative s uRFaces : Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and ...
Page 11 - Remove brick liners, see steps 1 to 4 in; screws and the control panel.
Maintenance And Service b uRneR anD F an R emovaL : 1. Remove brick liners, see steps 1 to 4 in S econdary i nStallation - b rick l iner r eMoval . 2. The control panel is held in place with a T-20 screw on each end of the panel. Remove the two (2) screws and the control panel. 3. Undo the four (4) ...
Page 12 - TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY; threads before installing into the brass elbow.; instructions supplied with the kit.; Remove the glass as shown in the
12 Maintenance And Service F ueL c onveRsion : TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Figure 10: Removing valve cap. 5. Convert the burner orifice(s): a) Remove the main burner orifice with a ½ inch deep socket.b) Put a bea...
Page 14 - Initial Installation; QUALIFIED INSTALLERS ONLY; no insulating material can be
Initial Installation QUALIFIED INSTALLERS ONLY i ntRoDuction : This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facings, mantels, and venting terminations will be covered, as well as the gas and electric systems. There are several install...
Page 16 - floor protection even when installed at floor level.; TILED FINISH
Initial Installation QUALIFIED INSTALLERS ONLY trim can be combustible as long as the hearth extends at least 12” (305 mm) in front of the fireplace and 1” (25 mm) on either side of the fireplace opening. To install the face, it is necessary for the bottom flange of the fireplace opening to overlap ...
Page 17 - D E
17 3½" (89mm) 8" (203mm) mantel Combustibles Cement Board DV42DX 10" (254mm) 12" (305mm) 17" (432mm) 20" (508mm) 8" (203mm) mantel Combustibles Cement Board DV42DX with Manor 10" (254mm) 12" (305mm) 17" (432mm) Figure 23. Combustible Mantel Clearances for The ...
Page 18 - NOTE: Venting terminals shall not be recessed into walls or siding.; Qnty; components are missing or damaged.
1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the requirements of the gas supplier. t A vent s...
Page 19 - INSTALLATION INSTRUCTIONS:
Flue Pipe Adaptor Wall Framing Wall Thimble Fire Stop Exhaust 4" Flex Pipe Combusion Air 6 5/8" Flex Pipe Wire Spacers Horizontal Vent Termination 19 INSTALLATION INSTRUCTIONS: 1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clea...
Page 20 - Manufacturer
9. Install the flex pipe assembly through the wall thimble, ensure that this portion of pipe slides through the outside wall far enough to connect onto the vent termination cap. 10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar adaptor previ...
Page 22 - WARNING: This gas appliance must not be connected
22 Initial Installation QUALIFIED INSTALLERS ONLY v enting : This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” PIPE FOR GAS STOVES, SECURITY CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, AMERICAN METAL PRODUCTS AMERIVENT DIRECT and DIRECT-TEMP SELKIRK ...
Page 24 - the possibility of a fire.
Wall framing Horizontal wall termination Wall thimble fire stop Exhaust flex pipe Combustion air outer pipe Elbow Initial Installation QUALIFIED INSTALLERS ONLY h oRizontaL t eRmination : NOTES:1. Horizontal pipes must not be level. For every 12 inches (305 mm) of horizontal travel (away from the st...
Page 26 - corrosion resistance.; Roof Pitch
Initial Installation QUALIFIED INSTALLERS ONLY STEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of sufficient size to meet minimum requirements for Clearance to Combustibles, as specified. Continue to assemble lengths of pipe and elbows neces...
Page 29 - DO NOT
29 Initial Installation QUALIFIED INSTALLERS ONLY e LectRicaL R equiRements : The fireplace must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTAL...
Page 30 - Always check for gas leaks with a soap; NEVER USE AN OPEN FLAME FOR LEAK TESTING.
Initial Installation g as L ine c onnection anD t esting : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating in...
Page 31 - Secondary Installation; WARNING: DO NOT INSTALL LINER IF UNIT IS HOT.; Important installation notes:
31 Secondary Installation b RicK L ineR R emovaL : There are two (2) different brick liner sets; the ceramic set that comes with the unit or the optional cast iron set. The following instructions are for both sets. WARNING: DO NOT INSTALL LINER IF UNIT IS HOT. 1. Remove glass door (see M aintenance ...
Page 32 - back log
Secondary Installation Figure 44: Shows the back log plus the two (2) small log twigs . Put the large back log in first, making sure the locator pins line up with the cutout sections on the log. There are two (2) pins with ledges and a single ledge on the back log. The back log sits on two (2) suppo...
Page 33 - left log
33 Figure 48: Final Log Set Arrangement with Embers. Secondary Installation Figure 49: DV42DX Burning. Figure 47: Fourth Stage Log Set Installation. Figure 47: The left log rests on the left pin and ledge of the back log and the back of the andiron. Figure 48: The last log, center log , rests on the...
Page 34 - Troubleshooting
Troubleshooting Problem Possible Cause Solution The main burner does not ignite when called for. The gas valve may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degrees above ambient temperature. Problem with...
Page 35 - Parts List - Components; Reference
35 Parts List - Components Reference Number Description Part Number 1 120°F (49°C) Ceramic Fan Temperature Sensor EC-001 2 S.I.T. Nova Valve Convertible 50-1421 3 Thermocouple EC-009 3 Spark Electrode with Ignitor Cable EC-011 3 Thermopile EC-012 3 Pilot Orifice NG Threaded EC-019 3 Pilot Orifice LP...
Page 36 - Parts Diagram - Components; om
Parts Diagram - Components 9 13 15 14 16 6 4 17 8 1 2 12 11 7 10 3 18 5 D V4 2D X - C om po ne nts N ov em be r 2 00 4 36
Page 38 - Parts Diagram - Options
Page 39 - Warranty; Limited Lifetime Warranty:; exclusions apply to this warranty.; To the Dealer; Sign and verify that work and information are correct.; Exclusions and Limitations:; Limited Warranty does not apply.
39 Warranty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the finest materials...
Page 40 - and as such is not covered under this warranty.
Warranty 4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs of neglect or misuse, it is not covered under the terms of this Warranty policy. Performance problems due to operator error will not be covered by the...
Page 42 - Installation Data Sheet
42 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ ___________________...