Page 3 - Notice; Documentation
i Notice Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Networks to determ...
Page 4 - Regulatory Compliance Information
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and ...
Page 5 - VCCI Notice
iii Electromagnetic Compatibility (EMC) This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, VCCI V ‐ 3. Compatibilidad Electromágnetica ...
Page 6 - Declaration of Conformity
iv Declaration of Conformity Application of Council Directive(s): 89/336/EEC73/23/EEC Manufacturer’s Name: Enterasys Networks, Inc. Manufacturer ’s Address: 50 Minuteman Road Andover, MA 01810 USA European Representative Address: Enterasys Networks, Ltd. Nexus House, Newb...
Page 7 - Firmware License Agreement
v Enterasys Networks, Inc. Firmware License Agreement BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc. on beha...
Page 9 - AUDIT
vii 8. AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys and, accordingly, You hereby agree to maintain complete books, records and accounts showing (...
Page 11 - Contents; About this Guide
ix Contents About this Guide Using This Guide ................................................................................................................................. xiStructure of This Guide .....................................................................................................
Page 13 - Using This Guide; Chapter 1; Introduction; Chapter 2; Installation; Appendix A; Specifications; In this document, the following terms are used:
SecureStack C2 Installation Guide xi About this Guide This guide provides an overview, installation and troubleshooting instructions, and specifications for the Enterasys SecureStack C2RPS ‐ SYS redundant power system components: chassis (C2RPS ‐ CHAS8), p...
Page 14 - Using the SecureStack C2 Manual Set; SecureStack; connected Ethernet Switch.
Using the SecureStack C2 Manual Set xii About this Guide Using the SecureStack C2 Manual Set Other manuals have been developed for the SecureStack C2 non ‐ PoE switch devices that can be connected to the RPS for power redundancy. The SecureStack C2 swi...
Page 15 - Conventions Used in This Guide; Elektrischer Gefahrenhinweis:
Conventions Used in This Guide SecureStack C2 Installation Guide xiii Conventions Used in This Guide The following conventions are used in this guide: Note: Calls the reader’s attention to any item of information that may be of special importance. Caution: Contains information essentia...
Page 17 - RPS; RPS Overview
SecureStack C2 Installation Guide 1-1 1 Introduction This chapter provides a functional overview of the Redundant Power System (RPS), which includes the following: RPS Overview The RPS provides a simple and economical solution for providing a bac...
Page 18 - Figure 1
RPS Overview 1-2 Introduction C2RPS-CHAS8 Chassis The chassis is a an eight ‐ slot frame without AC power connections or electronics. The chassis can be installed in a standard 19 ‐ inch rack and populated with up to eight PSMs. Each PSM ...
Page 19 - C2RPS-PSM Power Supply Module; Intake cooling fans
RPS Overview SecureStack C2 Installation Guide 1-3 C2RPS-PSM Power Supply Module The PSM provides the following: • Hot swap capability. • One 12 Vdc, 150 Watts of maximum ‐ continuous power output to a connected SecureStack C2 switch device. • Front pane...
Page 20 - RPS Deployment Strategies; SecureStack C2 Ethernet switches
RPS Deployment Strategies 1-4 Introduction RPS Deployment Strategies The RPS can be deployed in a variety of situations with mission ‐ critical applications. For example: • For use in a voice and data network where switches are connected to IP ph...
Page 21 - Getting Help; World Wide Web
Getting Help SecureStack C2 Installation Guide 1-5 Getting Help For additional support related to the devices or this document, contact Enterasys Networks using one of the following methods: Before contacting Enterasys Networks for technical support, ...
Page 23 - Required Tools; Table 2; Solamente personal calificado debe realizar procedimientos de; Installationen sollten nur durch ausgebildetes und
SecureStack C2 Installation Guide 2-1 2 Installation This chapter provides the installation instructions to install all the components of an RPS. To correctly install an RPS, follow the order of information listed below. Required Tools A flat ‐ blade...
Page 24 - Getting; Installing C2RPS-PSMs; Figure 2; Item; Item; C2RPS-PSM 150 Watt DC Power Supply Module
Installing C2RPS-PSMs 2-2 Installation 3. Perform a visual inspection of the switch devices for any signs of physical damage. Contact Enterasys Networks if there are any signs of damage. Refer to “ Getting Help ” on page 1 ‐ 5 for details...
Page 25 - Installing; Replacing an Installed C2RPS-PSM; Chassis power supply slot
Installing C2RPS-PSMs SecureStack C2 Installation Guide 2-3 5. Proceed to “ Installing C2RPS ‐ CHAS8 into the Rack ” on page 2 ‐ 4 for the rack mount installation instructions. Figure 2-1 C2RPS-PSM Installation Replacing an Installed C2RPS-PSM To replace a PSM ins...
Page 26 - Installing C2RPS-CHAS8 into the Rack; Guidelines for Rackmount Installation
Installing C2RPS-CHAS8 into the Rack 2-4 Installation 3. Pull the PSM out and remove it from the chassis. 4. Repeat steps 1 through 3 for each additional PSM you plan to remove. To install a PSM, proceed as follows: 1. Align the PSM with ...
Page 27 - Rack Mounting the Chassis; Para asegurar una buena ventilación y evitar que el sistema se
Installing C2RPS-CHAS8 into the Rack SecureStack C2 Installation Guide 2-5 • An ambient temperature of between 5 ° C (41 ° F) and 40 ° C (104 ° F) must be maintained at the installation site with fluctuations of less than 10 ° C (18 ° F) per hour. Ra...
Page 28 - Figure 2-2 Fastening the C2RPS-CHAS8 to the Rack; Connecting the PSM Cables and AC; Rails of 19-inch rack
Connecting the PSM Cables and AC Power Cords 2-6 Installation Figure 2-2 Fastening the C2RPS-CHAS8 to the Rack Connecting the PSM Cables and AC Power Cords The PSMs are connected to the SecureStack Ethernet switch devices using PSM cables. To connect the PSMs, pro...
Page 29 - Figure 2-4 Power Connectors on C2RPS-PSM; Redundant Power Supply connector
Connecting the PSM Cables and AC Power Cords SecureStack C2 Installation Guide 2-7 5. On certain switches, an LED indicator will show that a redundant power supply is now in operation. . Figure 2-3 C2RPS-PSM Cable Figure 2-4 Power Connectors on C2RPS-PSM (rear view)...
Page 30 - Figure 2-5 C2RPS-PSM Cable and AC Power Cord Connections; Switch device
Connecting the PSM Cables and AC Power Cords 2-8 Installation Figure 2-5 C2RPS-PSM Cable and AC Power Cord Connections 1 Switch device 4 Switch device Redundant Power Supply connector 2 PSM cable 5 AC power cord (type varies depending on country) 3 PSM Redundant Power Supply connector 6 AC power out...
Page 31 - Chassis; Table A; C2RPS-CHAS8 Chassis Specifications; Power supply slots
SecureStack C2 Installation Guide A-1 A Specifications This appendix provides information about the following: Enterasys Networks reserves the right to change the specifications at any time without notice. C2RPS-CHAS8 Chassis Specifications Table A ‐ 1 provide...
Page 32 - C2RPS-PSM Redundant Power Supply Output Connector; Figure A; Dimensions
C2RPS-PSM Specifications A-2 Specifications C2RPS-PSM Specifications Refer to Table A ‐ 2 for the input/output port specifications. C2RPS-PSM Redundant Power Supply Output Connector For pin location and function, refer to Figure A ‐ 1 and Table A ‐ 3 , respectivel...
Page 33 - Compliance Standards; Pin Number
Compliance Standards SecureStack C2 Installation Guide A-3 Compliance Standards The C2RPS ‐ PSM meets the safety and electromagnetic compatibility (EMC) requirements listed in Table A ‐ 4 : Table A-3 C2RPS-PSM Redundant Power Supply Connector Pin Functions Pin Number Function...