Page 3 - Notice
i Notice Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Networks to determ...
Page 4 - Regulatory Compliance Information
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and ...
Page 5 - Hazardous Substances
iii Electromagnetic Compatibility (EMC) This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 2004/108/EC, EN 55022, EN 61000 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, VCCI V ‐ 3. Compatibilidad Electromágnetica...
Page 6 - ѻક䇈ᯢк䰘ӊ; Supplement to Product Instructions; ᳝↦᳝ᆇ⠽䋼ܗユ
iv ѻ ѻક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼ܗ㋴ (Hazardous Substance) 䚼ӊৡ⿄ (Parts) 䪙 3E ∲ +J 䬝 &G ݁Ӌ䫀 &U ⒈㘨㣃 3%% ⒈Ѡ㣃䝮 3%'( 䞥ሲ䚼ӊ (Metal Parts) h ƻ ƻ h ƻ ƻ ⬉䏃ഫ ( Circuit Modules) h ƻ ƻ h ƻ ƻ ⬉㓚ঞ⬉㓚㒘ӊ ( Cables & Cable Assemblies) h ƻ ƻ h ƻ ƻ ล᭭㘮ড়⠽䚼ӊ (Plastic and Polymeric parts...
Page 8 - Declaration of Conformity; Enterasys Networks, Inc. Firmware License Agreement; BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,
vi Declaration of Conformity Application of Council Directive(s): 2004/108/EC2006/95/EC Manufacturer ’s Name: Enterasys Networks, Inc. Manufacturer ’s Address: 50 Minuteman Road Andover, MA 01810 USA European Representative Address: Enterasys Networks, Ltd. Nexus House, N...
Page 11 - Contents; About This Guide
ix Contents About This Guide Who Should Use This Guide ............................................................................................................................. xiHow to Use This Guide ..................................................................................................
Page 13 - Who Should Use This Guide; Important Notice
Matrix DFE-Platinum Series Module Installation Guide xi About This Guide This guide provides an overview, installation and troubleshooting instructions, and specifications for the Enterasys Matrix ™ DFE ‐ Diamond 7KR4297 ‐ 02 and 7KR4297 ‐ 04 modules and the...
Page 14 - How to Use This Guide; Refer to
How to Use This Guide xii About This Guide How to Use This Guide This preface provides an overview of this guide and the DFE ‐ Diamond Series manual set, a brief summary of each chapter, and defines the conventions used in this document. To l...
Page 15 - Document Conventions
Document Conventions Matrix DFE-Platinum Series Module Installation Guide xiii Document Conventions The following typographical conventions and icons are used in this document. Commonly Used Acronyms The following acronyms are used extensively throughout this guid...
Page 16 - Getting Help
Getting Help xiv About This Guide Getting Help For additional support related to the modules or this document, contact Enterasys Networks using one of the following methods: Before contacting Enterasys Networks for technical support, have the followi...
Page 17 - Introduction
Matrix DFE-Platinum Series Module Installation Guide 1-1 1 Introduction This chapter provides an overview of the Matrix DFE ‐ Diamond 7KR4297 ‐ 02 and 7KR4297 ‐ 04 modules and optional XFP 10 ‐ Gbps physical interface module. Overview of Matrix DFE-Diamond Modul...
Page 19 - Management; Switch Configuration Using WebView
Management Matrix DFE-Platinum Series Module Installation Guide 1-3 Figure 1-2 7KR4297-04 DFE-Diamond Module XFP 10GBASE-LR, -ER, -LX4, and -SR PHY S The LAN XFP PHYs (physical interfaces) provide inexpensive, high ‐ speed Ethernet connectivity. These PHYs provide network...
Page 20 - Secure Networks Policy Support
Secure Networks Policy Support 1-4 Introduction Secure Networks Policy Support Policy Enabled Networking manages the allocation of networking infrastructure resources in a secure and effective manner. Using Secure Networks Policy, an IT Administrator can...
Page 21 - Network Requirements; Table 2-1 Recommended Cable Types and Specifications
Matrix DFE-Platinum Series Module Installation Guide 2-1 2 Network Requirements Before installing the module, review the requirements and specifications referred to in this chapter concerning the following: The network installation must meet the requirem...
Page 22 - Module Placement in a Matrix E7 Chassis
Module Placement in a Matrix E7 Chassis 2-2 Network Requirements The uplinks have one fiber ‐ optic interface with an LC connector. Depending on the XFP and fiber ‐ optic cable used, the signal can be driven to a maximum distance of 33 m (108...
Page 23 - Installation
Matrix DFE-Platinum Series Module Installation Guide 3-1 3 Installation This chapter provides the instructions to install the DFE ‐ Diamond module and optional XFP interface modules. A Phillips screwdriver is required to install an optional interface m...
Page 24 - Unpacking the DFE-Diamond Module; Installing an Optional XFP Module; Preparation; Table 3-1 Carton Contents
Unpacking the DFE-Diamond Module 3-2 Installation Unpacking the DFE-Diamond Module Unpack the DFE ‐ Diamond module as follows: 1. Open the box and remove the packing material protecting the DFE ‐ Diamond module. 2. Verify the contents of the carton as li...
Page 25 - Figure 3-1 Installing an XFP; Removing an XFP Module; Backplane Connections and Installation Rules; FTM1 and FTM2 Connectivity
Backplane Connections and Installation Rules Matrix DFE-Platinum Series Module Installation Guide 3-3 Figure 3-1 Installing an XFP Removing an XFP Module To remove an XFP from the module port, refer back to Figure 3 ‐ 1 and proceed as follows: 1. Attach the antistat...
Page 26 - Module Placement and Rules; Matrix N3 Chassis, Module Placement; Figure 3-1 Examples, Module Placement in Matrix E7 Chassis
Backplane Connections and Installation Rules 3-4 Installation The DFE FTM bridging modules have a connection to both FTM1 and FTM2 backplanes, which enables them to switch frames between the two backplanes and all modules in the 6C107 chass...
Page 28 - Installing Module into Matrix E7 or Matrix N7 Chassis
Installing Module into Matrix E7 or Matrix N7 Chassis 3-6 Installation Example 6 ( Figure 3-1 , F) The module arrangement in this example is similar to the one shown in Figure 3 ‐ 1 , E and described in Example 5. The only difference is that a DFE ‐ Di...
Page 30 - Figure 3-2 Installing Module into Matrix E7 or Matrix N7 Chassis
Installing Module into Matrix E7 or Matrix N7 Chassis 3-8 Installation Figure 3-2 Installing Module into Matrix E7 or Matrix N7 Chassis 1 Card guides 5 Upper/lower locking tabs (in proper open position) 2 Slot number 6 (left-most slot is 1) 6 Upper/lower locking tab (in closed position) 3 Module 7 B...
Page 31 - Installing Module into Matrix N3 Chassis; Figure 3-3 Installing Module into Matrix N3 Chassis
Installing Module into Matrix N3 Chassis Matrix DFE-Platinum Series Module Installation Guide 3-9 Installing Module into Matrix N3 Chassis A DFE ‐ Diamond module can be installed in any available chassis slot (1 through 3). To install a DFE ‐ Diamond module into...
Page 32 - Connecting to the Network; Network Connection Using Fiber-Optic Cable
Connecting to the Network 3-10 Installation Connecting to the Network Network Connection Using Fiber-Optic Cable To connect the module to the network, refer to Figure 3 ‐ 4 and perform the following steps: 1. Remove any protective covers from the fiber ‐ optic...
Page 33 - RX; Connecting to COM Port for Local Management; What Is Needed; Figure 3-4 SC Fiber-Optic Cable Connection
Connecting to COM Port for Local Management Matrix DFE-Platinum Series Module Installation Guide 3-11 3. At the other end of the fiber ‐ optic cable, attach the SC connector to the other device. 4. Verify that a link exists by checking that the port ...
Page 34 - Connecting to an IBM PC or Compatible Device; optional
Connecting to COM Port for Local Management 3-12 Installation • RJ45 ‐ to ‐ DB25 female adapter • RJ45 ‐ to ‐ DB25 male adapter With a UTP straight ‐ cable with RJ45 connectors and RJ45 ‐ to ‐ DB9 adapter, you can connect products equipped with an RJ45 COM...
Page 35 - Connecting to a VT Series Terminal; Parameter
Connecting to COM Port for Local Management Matrix DFE-Platinum Series Module Installation Guide 3-13 Connecting to a VT Series Terminal To connect a VT Series terminal to an Enterasys Networks DFE ‐ Diamond module COM port ( Figure 3 ‐ 6 ), use a UTP straight ‐ cab...
Page 36 - Connecting to a Modem
Connecting to COM Port for Local Management 3-14 Installation When these parameters are set, the Local Management password screen will display. Refer to the Enterasys Matrix DFE ‐ Diamond/Platinum Series Configuration Guide for further information. Conne...
Page 37 - Adapter Wiring and Signal Assignments; Figure 3-7 Connecting to a Modem
Connecting to COM Port for Local Management Matrix DFE-Platinum Series Module Installation Guide 3-15 Adapter Wiring and Signal Assignments Figure 3-7 Connecting to a Modem 1 UTP straight-cable with RJ45 connectors 4 Local modem 2 RJ45 COM port 5 Remote modem 3 RJ45-to-DB25 male adapter COM Port Ada...
Page 38 - Completing the Installation; VT Series Port Adapter Wiring and Signal Diagram
Completing the Installation 3-16 Installation Completing the Installation Completing the DFE ‐ Diamond module installation depends on if the module is being installed in: • a new DFE ‐ Diamond module system (refer to “ Completing the Installation of a ...
Page 39 - Completing the Installation of a New System; First-Time Log-In Using a Console Port Connection
Completing the Installation Matrix DFE-Platinum Series Module Installation Guide 3-17 Completing the Installation of a New System In a new system of DFE ‐ Diamond modules, one of the installed DFE ‐ Diamond modules will become the management module on chassis ...
Page 40 - Logging in with an Administratively-Configured User Account; set password; set system login; set
Completing the Installation 3-18 Installation Figure 3-8 Matrix DFE Startup Screen Example (N7 Chassis) Completing Installation of DFE-Diamond Module in an Existing System In an established DFE ‐ Diamond module system, • a DFE ‐ Diamond module is already established as the ...
Page 43 - Troubleshooting
Matrix DFE-Platinum Series Module Installation Guide 4-1 4 Troubleshooting This chapter provides information concerning the following: Unless otherwise noted, the following information applies to all DFE ‐ Diamond modules. Using LANVIEW The modules use a built...
Page 45 - LED
Using LANVIEW Matrix DFE-Platinum Series Module Installation Guide 4-3 CPU None Power off. Ensure chassis has adequate power. Amber Blinking . Module in process of booting. None. Solid . Testing. If the LED remains amber for several minutes, contact Enterasys Networks for technical support. Green Bl...
Page 46 - Troubleshooting Checklist; Table 4-2 Troubleshooting Checklist
Troubleshooting Checklist 4-4 Troubleshooting Troubleshooting Checklist If the module is not working properly, refer to Table 4 ‐ 2 for a checklist of problems, possible causes, and recommended actions to resolve the problem. Table 4-2 Troubleshooting Ch...
Page 47 - Overview of DFE-Diamond Module Shutdown Procedure; Problem
Overview of DFE-Diamond Module Shutdown Procedure Matrix DFE-Platinum Series Module Installation Guide 4-5 Overview of DFE-Diamond Module Shutdown Procedure The DFE ‐ Diamond modules installed in a Matrix E7, Matrix N3, or Matrix N7 chassis are interdependent and op...
Page 48 - Recommended Shutdown Procedure Using OFFLINE/RESET Switch; press
Overview of DFE-Diamond Module Shutdown Procedure 4-6 Troubleshooting Recommended Shutdown Procedure Using OFFLINE/RESET Switch Before pulling a DFE ‐ Diamond module out of a chassis, press or tap on its OFFLINE/RESET switch for less than 1 second. Its CPU ...
Page 49 - Last Resort Shutdown Procedure Using OFFLINE/RESET Switch
Overview of DFE-Diamond Module Shutdown Procedure Matrix DFE-Platinum Series Module Installation Guide 4-7 Last Resort Shutdown Procedure Using OFFLINE/RESET Switch To reset a DFE ‐ Diamond module without it performing an orderly shutdown routine, press and hold the OFF...
Page 51 - Specifications; Table A-1 Specifications
Matrix DFE-Platinum Series Module Installation Guide A-1 A Specifications This appendix provides information about the following: Enterasys Networks reserves the right to change the specifications at any time without notice. DFE-Diamond Module Specifications Table...
Page 53 - COM Port Pinout Assignments; Table A-4 Recommended Cable Types and Specifications; Table A-5 COM Port Pin Assignments
COM Port Pinout Assignments Matrix DFE-Platinum Series Module Installation Guide A-3 Table A ‐ 3 provides the input/output specifications for each XFP version as specified in the IEEE 802.3ae ‐ 2002 standard. The following XFP specifications in Table A ‐ 4 m...
Page 54 - Regulatory Compliance; Table A-6 Compliance Standards
Regulatory Compliance A-4 Specifications Regulatory Compliance The 7KR4297 ‐ 02 and 7KR4297 ‐ 04 modules meet the safety and electromagnetic compatibility (EMC) requirements listed in Table A ‐ 6 : Table A-6 Compliance Standards Regulatory Compliance Standards Safety UL...
Page 55 - Mode Switch Bank Settings
Matrix DFE-Platinum Series Module Installation Guide B-1 B Mode Switch Bank Settings and Optional Installations This appendix covers the following items: Required Tools Use the following tools to perform the procedures provided in this appendix: • Antistatic wrist ...
Page 56 - Memory Locations and Replacement Procedures; Figure B-1 Mode Switch Location
Memory Locations and Replacement Procedures B-2 Mode Switch Bank Settings and Optional Installations • Switch 7 – Clear Persistent Data. Changing the position of this switch clears Persistent Data on the next power ‐ up of the module. All user ‐ entered ...
Page 57 - Location of DIMM and DRAM SIMM Memory Modules; DRAM SIMM Replacement Procedure; Removing the DRAM SIMM; Figure B-2 DIMM and DRAM SIMM Locations
Memory Locations and Replacement Procedures Matrix DFE-Platinum Series Module Installation Guide B-3 Location of DIMM and DRAM SIMM Memory Modules Figure B ‐ 2 shows the locations of the DIMM and DRAM SIMM on the main board. DRAM SIMM Replacement Procedure To remove a...
Page 58 - Installing the DRAM SIMM; Figure B-3 Removing the Existing DRAM SIMM
Memory Locations and Replacement Procedures B-4 Mode Switch Bank Settings and Optional Installations 3. Pull the DRAM SIMM straight up and remove it from the connector fingers. Installing the DRAM SIMM To install a DRAM SIMM, refer to Figure B ‐ 4 and procee...
Page 59 - DIMM Replacement Procedure; Removing the DIMM; Figure B-4 Installing the DRAM SIMM
Memory Locations and Replacement Procedures Matrix DFE-Platinum Series Module Installation Guide B-5 DIMM Replacement Procedure In the event that the DIMM needs to be replaced, the following sections explain how to remove and install the DIMM. If you hav...
Page 60 - Installing the DIMM; Figure B-5 Removing the Existing DIMM
Memory Locations and Replacement Procedures B-6 Mode Switch Bank Settings and Optional Installations 3. Rotate the DIMM upwards, then remove it from the connector fingers. Installing the DIMM To install a DIMM, refer to Figure B ‐ 6 and proceed as follows: 1. ...
Page 61 - Figure B-6 Installing the DIMM
Memory Locations and Replacement Procedures Matrix DFE-Platinum Series Module Installation Guide B-7 Figure B-6 Installing the DIMM 1 DIMM 3 Connector arms 2 Connector fingers 4 DIMM alignment notches (2) Â Á Ã Ã Â À
Page 63 - Index; Numerics
Index-1 Index Numerics 10GBASE-xx module installing a 3-2 10-Gigabit Ethernet Transceiver Specifications (XFP) A-2 7KR4297-02 introduction to 1-2 7KR4297-04 Introduction to 1-2 A Acronyms commonly used xiii C Capabilities DFE module 1-1 CLI command introduction to 1-3 COM port connections what is ne...