Page 2 - TABLE Of CONTENTS; Specifications; SECTION
26670-0-0110 Page 2 TABLE Of CONTENTS Carton Contents ......................................................................................................................3 Hardware Package ................................................................................................................
Page 3 - CARTON CONTENTS; Installation package; HARDWARE PACKAGE
26670-0-0110 Page 3 CARTON CONTENTS Fireplace AssemblyLava Rock PackageSoot Warning Sheet Installation package Rockwool Packet Installation Instructions Serial Number Tag Warranty Card Hardware Package (See Figure Below) Nailing Flange #10 x 1/2" Phillips Hex Head Screw #10 x 1/2" Phillips T...
Page 4 - WARNINg; IMpORTANT SAfETy INfORMATION
26670-0-0110 Page 4 When used without adequate combustion and ventilation air, heater may give off CARBON MONOXIDE, an odorless, poi- sonous gas. Do not install heater until all necessary provisions are made for combustion and ventilation air. Consult the writ- ten instructions provided with the hea...
Page 5 - SOME pOINTS TO REMEMBER; SAfETy INfORMATION fOR USERS Of Lp-gAS
26670-0-0110 Page 5 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to dete...
Page 6 - INTRODUCTION
26670-0-0110 Page 6 Installation on Rugs and Tile If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. The base referred to abov...
Page 7 - SpECIfICATIONS
26670-0-0110 Page 7 Model VFP36(SP,PP)32EN (NAT) VFP36(SP,PP)32EP (LP) Input Maximum 38,000 38,000 Minimum 25,000 30,000 Overall Dimensions Height without standoff 37 3/4" 37 3/4" Width 39" 39" Depth 24" 24" Gas Inlet 3/8" 3/8" Log Sets (ordered Separately) LSU24RR-2 ...
Page 8 - WATER vApOR: A By-pRODUCT Of UNvENTED ROOM hEATERS; pROvISIONS fOR ADEqUATE COMBUSTION & vENTILATION AIR
26670-0-0110 Page 8 Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source ...
Page 10 - gAS SUppLy; Recommended gas pipe Diameter; Pipe Length
26670-0-0110 Page 10 Check all local codes for requirements, especially for the size and type of gas supply line required. Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: Since some municipalities have additional local codes, it is alw...
Page 11 - CLEARANCES
26670-0-0110 Page 11 CLEARANCES figure 4a - See Through fireplace Clearances 36” MIN. 42” MIN. (CEILING TO TOP OF HOOD) 1 3/4” MIN. PERPENDICULAR COMBUSTIBLE SIDEWALL 36” MIN. 42” MIN. (CEILING TO TOP OF HOOD) 1 3/4” MIN. PERPENDICULAR COMBUSTIBLE SIDEWALL figure 4b - peninsula fireplace Clearances ...
Page 12 - COMBUSTIBLE MATERIALS
26670-0-0110 Page 12 CLEARANCES (cont.) figure 6a - Mantel Clearances with Standard hood figure 6b - Mantel Clearances with Optional Extended hood MANTEL STANDARDHOOD 17 ½” 10” 12” MAX 42” MIN. (CEILING TOTOP OF HOOD) 4 ½” MIN. FIREBOXFACE 84” MIN. (CEILING TO FLOOR) CEILING COMBUSTIBLES ALLOWED 3/8...
Page 13 - fIREpLACE INSTALLATION INSTRUCTIONS; pLANNINg INSTALLATION
26670-0-0110 Page 13 fireplace framing Framing can be built before or after the fireplace is set in place. Framing should be constructed to accommodate wall covering and fireplace facing material. The fireplace framing should be constructed of 2 x 4 lumber or heavier. The framing headers may rest on...
Page 14 - FIREPLACE INSTALLATIoN INSTRUCTIoNS (continued)
26670-0-0110 Page 14 Figure 10 fireplace Dimensions FIREPLACE INSTALLATIoN INSTRUCTIoNS (continued) vfp36Sp vfp36pp A 34 3/4" 34 3/4" B 39" 39" C 24" 24" D 22" 22" E 36" 36" f 34 1/4" 35 1/4" g 29 1/8" 29 1/8" h 37 3/4" 37 3/4" I 1 1/4&...
Page 15 - CHECK TO SEE
26670-0-0110 Page 15 Locating fireplace Place fireplace in framed opening. Attach the framing brackets to the fireplace and secure to framing. Different hole locations can be used for finishing materials with thicknesses of 3/8", 1/2" and 3/4". Secure the brackets with screws provided us...
Page 16 - INSTALLINg hOODS
26670-0-0110 Page 16 Extended hoods If your non-combustible facing material is over 1" in thickness and will be used to finish this fireplace, extended hoods are available that will extend out 2" farther into the room. Extended hoods are not available for the peninsula open ends. Contact you...
Page 17 - gAS LINE CONNECTION
26670-0-0110 Page 17 The fireplace is designed to accept a gas line for connection to the gas valve. Have the line installed by a qualified service person in accordance with all building codes. Consult local building codes to properly size the gas supply line leading to the connection of the valve. ...
Page 18 - PLACEMENT oF GLoWING EMBERS AND LAVA RoCK; NAT BURNER - TOP VIEW
26670-0-0110 Page 18 Placement of the glowing embers (rockwool) is very individual and light coverage of the areas indicated will provide your best effects. We recommend separation of the rockwool by hand and to make your coverage as light and fluffy as possible. Place just enough embers on the burn...
Page 19 - oPERATIoN INSTRUCTIoNS/FLAME APPEARANCE
26670-0-0110 Page 19 Before you begin: Do not handle the logs with your bare hands! Always wear gloves to prevent skin irritation. After handling logs, wash your hands gently with soap and water. All Logs The positioning of the logs is critical to the safe and clean opera- tion of this heater. Sooti...
Page 20 - MILLIvOLT vALvE LIghTINg INSTRUCTIONS; FOR YOUR SAFETY READ BEFORE LIGHTING; ing property damage, personal injury or loss of life.
26670-0-0110 Page 20 1. STOP! Read the safety information label. 2. Open bottom louver assembly. 3. Set REMOTE/OFF/ON switch to "OFF." 4. Turn off all electric power to the appliance (if applicable). 5. Push in gas control knob slightly and turn clockwise to "OFF." NOTE: Knob cannot ...
Page 21 - • Check all carryover ports for blockage from the ceramic; BURNER INSTRUCTIONS
26670-0-0110 Page 21 Check the following items during installation prior to lighting the multisided burner: • Check all carryover ports for blockage from the ceramic media o If there is blockage, use a small pointed tool to move the ceramic media away from the carryover port. • Check air shutter for...
Page 22 - pILOT fLAME ChARACTERISTICS
26670-0-0110 Page 22 Figure 16 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 17 show an ...
Page 23 - WIRING DIAGRAM; WIRINg
26670-0-0110 Page 23 Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.Millivolt thermopile is self powered, gas valve does not require 110 volts. Maximum length of 20 feet of 16 AWG two (...
Page 24 - TROUBLEShOOTINg; SyMpTOMS - pOSSIBLE CAUSES AND CORRECTIONS
26670-0-0110 Page 24 If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately. 1. When ignitor button is pressed, there is no spark at oDS/ pilot. a. I...
Page 25 - WIRING INSTRUCTIoNS FoR INSTALLING A DUAL SWITCH / RECEPTACLE
26670-0-0110 Page 25 WIRING INSTRUCTIoNS FoR INSTALLING A DUAL SWITCH / RECEPTACLE In order to install both the optional Blower and Accent Light ac- cessories, it will be necessary to install the junction box so that the Duplex Receptacle wiring is split. This will allow each side of the receptacle ...
Page 26 - oPTIoNAL FBB5 BLoWER INSTALLATIoN INSTRUCTIoNS
26670-0-0110 Page 26 Attention: Install blower assembly before connecting gas in- let supply line. Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 , if an exter- nal ...
Page 27 - oPTIoNAL BLoWER INSTALLATIoN INSTRUCTIoNS (continued)
26670-0-0110 Page 27 4. Insert blower assembly into interior, bottom of firebox. Note: On peninsula models, the blower must be installed at the end which has the brick panel installed. Position blower assembly so that you align the notch on back of blower as- sembly with the center screw on side/end...
Page 29 - MAINTENANCE; LK2 ACCENT LIGHT ACCESSoRY
26670-0-0110 Page 29 MAINTENANCE Keep the control compartment, logs and burner area surround- ing the logs clean by vacuuming or brushing area at least twice a year. THE LOGS CAN GET VERY HOT - HANDLE ONLY WHEN COOL.Always turn off gas to the pilot before cleaning. For relighting, refer to the light...
Page 30 - pARTS LIST
26670-0-0110 Page 30 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. NOTE: SEE LOG INSTRUCTION MANUAL FOR DETAILS ON LOGS AND EMBERS ATTENTION: When ordering parts, it is very important that part number and description of part coincide. pARTS LIST INDEX...
Page 32 - SEE-ThROUgh fIREpLACE pARTS vIEW
26670-0-0110 Page 32 SEE-ThROUgh fIREpLACE pARTS vIEW 1 4 6 5 16 8 9 12 14 4 5 6 8 12 14 9 7 3 2 24 25 20 17 18 31 41 40 21 23 29 33 30 19 22 34 28 26 Nat Gas 36 37 35 27 42 32 38 39 24 25 43 44 45 46 47 44 21 NAT. BURNER
Page 33 - pENINSULA fIREpLACE pARTS vIEW
26670-0-0110 Page 33 pENINSULA fIREpLACE pARTS vIEW 1 4 5 6 8 9 11 10 12 13 14 15 16 8 12 14 9 7 3 2 24 25 20 17 18 31 41 40 21 23 29 33 30 19 22 34 28 26 Nat Gas 36 37 35 27 42 32 38 39 24 LP BURNER 25 43 44 45 46 47 44 21 NAT. BURNER
Page 34 - ACCESSORIES
26670-0-0110 Page 34 Accessory Description Model Numbers Fan Kit 1 2 Designed to provide forced air flow. FBB5 Variable Speed Control Kit Wall mounted variable speed control for use with FBB5 blower SCV-1 Frame Kits Standard 3-Piece Frame Kits Black, Brass, Stainless Steel, or Hammered Pewter Extrud...
Page 36 - SERvICE NOTES
Page 37 - Premium Vent-Free Fireplaces; Empire Comfort Systems; EMPIRE
26670-0-0110 Page 37 Web Site: www.empirecomfort.com Premium Vent-Free Fireplaces SEE-THROUGH FIREPLACE MODELS: VFP36SP32EN-2 VFP36SP32EP-2 PENINSULA FIREPLACE MODELS: VFP36PP32EN-2 VFP36PP32EP-2 Empire Comfort Systems 918 Freeburg Avenue Belleville, Illinois 62220-2623 GAS-FIRED 36-inch Fireplace a...
Page 38 - Clearances
26670-0-0110 Page 38 Web Site: www.empirecomfort.com Premium Vent-Free Fireplaces SEE-THROUGH FIREPLACE MODELS: PENINSULA FIREPLACE MODELS: VFP36SP32EN-2 VFP36PP32EN-2 VFP36SP32EP-2 VFP36PP32EP-2 Empire Comfort Systems 918 Freeburg Avenue Belleville, Illinois 62220-2623 Mantel Clearances with Standa...