Page 2 - TABLE OF CONTENTS
16941-5-0907 Page 2 SECTION PAGE Important Safety Information .....................................................................................3Safety Information for Users of LP Gas .....................................................................4Introduction .................................
Page 3 - IMPORTANT SAFETY INFORMATION
16941-5-0907 Page 3 • An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom or bathroom. • Due to high temperatures, th...
Page 4 - SAFETY INFORMATION FOR USERS OF LP-GAS
16941-5-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detec...
Page 6 - WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS; PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR
16941-5-0907 Page 6 Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of gas input per hour. Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an...
Page 7 - GAS SUPPLY
16941-5-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Gas Supply Check all local codes for requirements, e...
Page 10 - WALL MOUNT INSTALLATION
16941-5-0907 Page 10 Refer to Figures 7, 8 and 9 for measurements in order to locate (4) mounting holes on wall. Figures 7, 8 and 9 are the front views of the heaters. 1. Remove lower louver from casing assembly (2 screws). 2. Remove reflector from casing assembly (2 screws). 3. Remove upper louver f...
Page 11 - OPTIONAL FLOOR STAND INSTALLATION
16941-5-0907 Page 11 4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver, be sure the bottom lip of...
Page 12 - FOR YOUR SAFETY READ BEFORE LIGHTING; TO TURN OFF GAS TO APPLIANCE; LIGHTING INSTRUCTIONS
16941-5-0907 Page 12 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow t...
Page 13 - MAIN BURNER FLAME CHARACTERISTICS
16941-5-0907 Page 13 SR-10T, SR-18T and SR-30T Main Burner Flame (Figure12) The main burner flame will have a red-orange glow over the surface of the ceramic plaques. A few small, hairline cracks may form over the surface of the ceramic plaques or at the edges of the ceramic plaques where they have b...
Page 14 - PILOT FLAME CHARACTERISTICS
16941-5-0907 Page 14 The correct flame will be blue and will extend beyond the ther- mocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 13 Oxygen Depletion Sensor Pilot (Figure 14) When the pilot ...
Page 15 - APPLIANCE MAINTENANCE
16941-5-0907 Page 15 Removing Pilot/Thermocouple From Main Burner Assembly Attention: The thermocouple CAN NOT be replaced as an individual item. You must order a new pilot when replacing thermocouple. 1. Turn OFF gas supply to the heater. 2. Turn OFF electrical supply to the heater if optional blow...
Page 17 - PARTS LIST
16941-5-0907 Page 17 INDEX PART NUMBER NUMBER DESCRIPTION SR-18T INDEX PART NUMBER NUMBER DESCRIPTION 1 13348 CASING SIDE ASSEMBLY - LEFT 2 SR-090 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBLY - RIGHT 5 SR-113 VALVE BRACKET 6 R-6563 GAS VALVE -SIT 7 R-2330 BURNER 8 SR-119 ORIFICE ...
Page 18 - PARTS VIEW
Page 21 - OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
16941-5-0907 Page 21 REFLECT OR AND LOUVER S ARE REMOVED FROM CASING ASSEMBL Y GROUND WIRE SCRE W FAN CONTROL HEAT SHIELD CORD SET HOLE IN CASING BAC K INSTALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is installed onto the wall, in order to install the optional blower, the heater must be remo...
Page 22 - OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued)
16941-5-0907 Page 22 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code, ANSI/NFPA 70, if an external electrical source is utilized . This appliance is equipped with a three-prong [...
Page 23 - SERVICE NOTES