Page 2 - SECTION PAGE; Recommended Vent Con; TABLE OF CONTENTS
Page 2 12426-4-0104 SECTION PAGE Important Safety Information .................................................................................................3Safety Information for Users of LP Gas .................................................................................4Introduction .........
Page 3 - THIS IS A HEATING APPLIANCE; DO NOT OPERATE THIS APPLIANCE WITHOUT OUTER CASING INSTALLED.; IMPORTANT SAFETY INFORMATION
12426-4-0104 Page 3 THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT OUTER CASING INSTALLED. IMPORTANT SAFETY INFORMATION • DO NOT put anything around the furnace that will obstruct the ß ow of combustion and ventilation air. • DO keep the appliance area clear and free from combusti...
Page 4 - SAFETY INFORMATION FOR USERS OF LP-GAS
Page 4 12426-4-0104 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must Þ nd out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to dete...
Page 5 - INTRODUCTION
12426-4-0104 Page 5 Introduction Vented wall furnace is shipped ready to install in a 2" x 4" stud wall, with studs 16" (406mm) center to center. Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented wall furn...
Page 6 - RECOMMENDED VENT CONFIGURATION
Page 6 12426-4-0104 Note: No vent equipment supplied with furnace. 4" Oval (all parts purchase locally) 1. Type B-1 oval pipe 2. Single story type B-1 gas vents require a baseplate and one pair of ceiling plate spacers. 3. Multi-story type B-1 gas vents require a baseplate, one pair of ceiling p...
Page 7 - GAS SUPPLY
12426-4-0104 Page 7 Check all local codes for requirements, especially for the size and type of gas supply line required. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L (Feet) Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 1/2" 3/8" 1/2" 3/8" 1.3...
Page 9 - FINISHING INSTRUCTIONS
12426-4-0104 Page 9 Figure 2 FINISHING INSTRUCTIONS Plastering (Figure 4) In new construction use only plain (not perforated) gypsum lath around furnace and vent pipe so that plaster "Keys" will not project into wall space. Use wood strips nailed to inside of studs and top of bottom plate. T...
Page 12 - FOR YOUR SAFETY READ BEFORE LIGHTING; WARNING: If you do not follow these instructions exactly, a; TO TURN OFF GAS TO APPLIANCE
Page 12 12426-4-0104 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a Þ re or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow th...
Page 13 - PROPER PILOT FLAME
12426-4-0104 Page 13 VENT SAFETY SHUTOFF SYSTEM PROPER MAIN BURNER FLAME This appliance must be properly connected to a venting system. This appliance is equipped with a vent safety shutoff system. Warning: Operation of this wall furnace when not connected to a properly installed and maintained vent...
Page 14 - TROUBLESHOOTING
Page 14 12426-4-0104 GENERAL All furnaces have been Þ re-tested to check for proper operation. This includes main burner ß ame, pilot ß ame, and gas control operation. If the furnace fails to function on initial installation, it is advisable to re-check the following: 1. Inlet gas pressure.2. Type o...
Page 15 - PARTS LIST
12426-4-0104 Page 15 1 WFA-115 HEADER GASKET 2 GWT-175 HEADER ASSEMBLY (INCLUDES NO. 1, GASKET) (USA) 2 15756 HEADER ASSEMBLY (INCLUDES NO. 1, GASKET) (CANADA) 3 GWT-184 INNER CASING ASSEMBLY 4 GWT-151 DIVERTER ASSEMBLY (2 REQUIRED) 5 GWT-020 FRONT SHIELD (2 REQUIRED) 6 GWT-077 HEAT SHIELD (2 REQUIR...
Page 16 - PARTS VIEW
Page 17 - REMOTE BULB CONTROL INSTALLATION INSTRUCTIONS
12426-4-0104 Page 17 No. Number Description 1 GW- 130 Remote Bulb Control Kit 2 R-1224 Remote Bulb Control 3 R-2499 Wire Assembly 4 R-1162 Control Knob 5 R-1720 Plastic Clip (3 Required) 6 R-1223 Instructions 7 R-1578 No. 6-32 x 1/4" (6mm) Screw (2 Required) Caution: Remote bulb wire routing is ...
Page 18 - OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
Page 18 12426-4-0104 GWTB-2 FOR MODELS GWT-25 (SG, RB) , GWT-35 (SG, RB) , GWT-50 (SG, RB) OPTIONAL BLOWER INSTALLATION INSTRUCTIONS Installing Blower Using Three-Prong Plug 1. Install furnace according to Installation Instructions and Owner's Manual. 2. Refer to Drawing for measurements to locate (...
Page 20 - SERVICE NOTES
Page 20 12426-4-0104 SERVICE NOTES Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62220-2623 PH: 1-618-233-7420PH: 1-800-851-3153 FAX: 1-618-233-7097FAX: 1-800-443-8648 E-MAIL: [email protected] WEB SITE: www.empirecomfort.com