Page 2 - Section Page; TABLE OF CONTENTS
23552-1-0607 Page 2 Important Safety Information ............................................................................................................................ 3Safety Information for Users of LP Gas .........................................................................................
Page 3 - IMPORTANT SAFETY INFORMATION
23552-1-0607 Page 3 DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. • Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. • The...
Page 4 - SAFETY INFORMATION FOR USERS OF LP GAS
23552-1-0607 Page 4 SOME POINTS TO REMEMBER NO ODOR DETECTED - ODOR FADE LP-GAS WARNING ODOR If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. That’s your signal to go into immediate action! SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is...
Page 5 - REQUIREMENTS FOR MASSACHUSETTS; “GAS VENT DIRECTLY BELOW.
23552-1-0607 Page 5 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust ve...
Page 6 - INTRODUCTION
23552-1-0607 Page 6 Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with the fireplace. 3. Installer should show owner how to start and operate the fireplace. This direct vent gas fi...
Page 7 - SPECIFICATIONS
23552-1-0607 Page 7 Figure 1 Dim DVD32 DVD36 DVD42 DVD48 A 34" 864mm 37" 940 mm 43" 1092 mm 49" 1245 mm B 31" 787 mm 34" 864 mm 40" 1016 mm 46" 1168 mm C 23 1/16" 585 mm 23 1/16" 585 mm 25 1/16" 636 mm 25 1/16" 636 mm D 35 5/8" 905 mm 35 5/8" 9...
Page 8 - Figure 5; CLEARANCES
23552-1-0607 Page 8 Mantel Chart (Figure 3) Figure 3 Clearances (Figure 4) Clearance from top front edge of fireplace to ceiling is 36" Clearance from side of fireplace to adjacent sidewall is 6". Figure 4 15” (381mm) TOP EDGE OF FIREPLACE 12” (305mm) 10” (254mm) MANTEL COMBUSTIBLE TRIM AND MA...
Page 9 - GAS SUPPLY
23552-1-0607 Page 9 Figure 6 T he gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code. Installing a New Main Gas Cock Each appliance should have its own manual gas cock.A man...
Page 10 - REAR VENT CONVERSION; Converting flue take-off to rear venting; SPECIAL VENT SYSTEMS; The following vent systems are acceptable for use with the; * Can not be used in side wall horizontal vent
23552-1-0607 Page 10 Note : Discard insulation & retainer when using vertical venting off VERTICAL VENTING HORIZONTAL VENTING FLUE INSULATION INSULATION RETAINER INLET VENT COLLAR INLET VENT COLLAR FLUE OUTLET COLLAR FLUE COVER PLATE (See note above) INLET VENT COVER PLATE FLUE COVER PLATE INLET...
Page 11 - Top of Vent; INSTALLATION
23552-1-0607 Page 11 Framing and Finishing 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to allow for finished face when setting the depth of the frame. 3. Attach fireplace to frame using adjustable frame. Preset depth to suit facing material (adjustable t...
Page 13 - VERTICAL, 90° ELBOW WITH HORIZONTAL
23552-1-0607 Page 13 Flush Wall Installation Figure 12 Combustible Surround Installation Figure 13 Attention: Cold climate installation recommendation: When installing this unit against a non-insulated exterior wall, it is recommended that the outer walls be insulated to conform to applicable insula...
Page 15 - VENTING FIREPLACE - TOP
23552-1-0607 Page 15 To Use the Vent Graph (Figure 19) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the b...
Page 16 - Firestop at
23552-1-0607 Page 16 Figure 21 Examples of possible venting systems using two (2) 90° elbows. V is listed as minimum vertical dimensions and H1 + H2 is listed as total of maximum horizontal dimensions. The maximum vertical and horizontal distances for two (2) 90° elbows as shown in Figure 22 is 20 f...
Page 18 - EXAMPLES - TOP VENT RUN
23552-1-0607 Page 18 Figure 26 Figure 27 Figure 28 24” 24” MINIMUM CLEARANCE TO COMBUSTIBLES EXAMPLES - TOP VENT RUN
Page 19 - VENTING FIREPLACE - REAR
23552-1-0607 Page 19 To Use the Vent Graph (Figure 29) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the b...
Page 20 - EXAMPLES - REAR VENT RUN
23552-1-0607 Page 20 Figure 30 Figure 31 Figure 32 Figure 33 Model Maximum Pipe Length H1 DVD32 24" DVD36 24" DVD42 18" DVD48 N/A Model Maximum Pipe Length H1 DVD32 24" DVD36 24" DVD42 24" DVD48 6" EXAMPLES - REAR VENT RUN
Page 21 - TERMINATION CLEARANCES
23552-1-0607 Page 21 Termination clearance for buildings with combustible and noncombustible exteriors. Vertical Sidewall Installations Important! Minimum clearance between vent pipes and combustible materials is three (3") (76mm) on top, and (1") (25mm) on bottom and sides. Important! When ...
Page 22 - VENT CLEARANCES
23552-1-0607 Page 22 Figure 35 A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum] B = clearance to window or door that may be opened [*12 inches (30cm) minimum for appliances < 100,000 BTU/Hr (30kW) C = clearance to permanently closed window [minimum 12 inches...
Page 23 - VENT SYSTEM IDENTIFICATION
23552-1-0607 Page 23 I nstalling Vent Components (Figure 36) Begin the vent system installation by installing the first Simpson Duravent component, 90° elbow to the starting collars or straight pipe on the top of the appliance, then the straight pipe length and then horizontal or vertical termination...
Page 24 - FRAMING AND FINISHING
23552-1-0607 Page 24 Installing Support Brackets (Figure 37) A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports should be placed around the pipe and nailed in place to framing members. There MUST BE a 3 inch clearance to combustibles above 6 5/8 inch diameter...
Page 25 - Horizontal Termination
23552-1-0607 Page 25 Figure 39 Figure 41 See Horizontal Termination Page 26 and Vertical Termination Pages 31-32. Figure 40 FRAMING AND FINISHING (continued)
Page 26 - HORIZONTAL TERMINATION
23552-1-0607 Page 26 NOTE: Termination cap should pass through the wall firestop from the exterior of the building. Adjust the termination cap to its final exterior position on the building. WARNING: Termination cap must be positioned so that arrow is pointing up. Attach the termination cap with the f...
Page 27 - DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS
23552-1-0607 Page 27 C A U T I O N : S h a r p e d g e s , u s e p ro t e c t i v e g l o v e s w h e n installing. Tools Needed for Installation: Sheet metal snips 5/16” nut driver Phillips head screwdriver - #2 High temperature sealant or furnace cement rated for continuous use at 1,000 o F minimu...
Page 28 - Sealing 4” (102mm) Diameter Flue Outlet Tube; Figure 3A
23552-1-0607 Page 28 7. Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8” (168mm) diameter tube from the opposite end. Do not crimp or enlarge tube. 8. Attach the 4” (102mm) diameter flue outlet tube onto the rigid venting system or directly to fir...
Page 30 - DVVK-4F FLEX VENT KIT; DVVK-4F FLEX VENT INSTRUCTIONS
23552-1-0607 Page 30 INSTALLATION 1. Unpack vent components and check that all items are included. 2. Check to see that the vent spacer springs are located around the flue vent at 8" and 12" intervals along its length. See Figure A. If not, stretch the spacer springs to about 15" long and...
Page 31 - VERTICAL TERMINATION
23552-1-0607 Page 31 Locate and mark the center point of the vent pipe using a nail on the underside of the roof. Drive the nail through the center point. Mark the outline of the roof hole around this center point. NOTE: Size of the roof hole dimensions depend on the pitch of the roof. There must be...
Page 35 - OPERATING INSTRUCTIONS
23552-1-0607 Page 35 The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the gas controls for the fireplace. Initial Lighting Upon completing the gas line or turning the gas valve on after it has been in the “OFF” position, a small amo...
Page 37 - STANDING PILOT WIRING DIAGRAM
23552-1-0607 Page 37 Figure 57 (OPTIONAL) THERMOSTAT (OPTIONAL) WALL SWITCH STANDING PILOT WIRING DIAGRAM
Page 38 - STANDING PILOT LIGHTING INSTRUCTIONS
23552-1-0607 Page 38 1. Stop! Read the safety information above. 2. Set REMOTE/OFF/ON switch to OFF. 3. Turn off all electric power to the appliance (if applicable). 4. Lower bottom louver assembly. 5. Push in gas control knob slightly and turn clockwise to "OFF." Note: Knob cannot be turned...
Page 39 - STANDING PILOT TROUBLESHOOTING
23552-1-0607 Page 39 With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and t...
Page 40 - DIRECT IGNITION WIRING DIAGRAM; OPTIONAL REMOTE CONTROL
23552-1-0607 Page 40 DIRECT IGNITION WIRING DIAGRAM LED LIGHT LED LUMIÈRE BLACK NOIR GREEN VERT WHITE BLANC RED ROUGE BLACK NOIR GAS VALVE VALVE DE GAZ (OPTIONAL) WALL SWITCH INTERRUPTEUR MURAL (FACULTATIVE) 120 VAC LINE 120 VAC RTN JUNCTION BOX JONCTION BOÎTE SPARK IGNITOR ÉTINCELLE ALLUMER (OPTION...
Page 41 - PURGE PROCEDURE; INITIAL START UP GAS LINE PURGE; WHAT TO DO IF YOU SMELL GAS; LIGHTING INSTRUCTIONS; RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.; TO TURN OFF GAS TO APPLIANCE; DIRECT IGNITION LIGHTING INSTRUCTIONS
23552-1-0607 Page 41 1. Remove glass door and place away from the fireplace. 2. Turn on gas shut off valve. Follow ignition procedure. 3. If burner does not light after spark sequence has ended, use an insulated jumper wire (see page 40) between terminal locations 12 and 13 for fast reset function. 4...
Page 43 - Maxitrol Valve Conversion; DIRECT IGNITION PROPANE/LP GAS CONVERSION
23552-1-0607 Page 43 1. Turn off the gas supply. 2. Turn off the electrical supply to the appliance if so equipped. 3. Remove top louver and lower bottom louver. 4. Remove glass frame assembly. 5. Remove logs from burner assembly. VALVE CONVERSION 6. Remove plastic cap from regulator fitting. Unscrew...
Page 44 - MAINTENANCE AND SERVICE
23552-1-0607 Page 44 PLEASE NOTE It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your gas fireplace to give off so...
Page 45 - PARTS LIST
23552-1-0607 Page 45 USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. INDEX NO. PART NUMBER DESCRIPTION DVD32 DVD36 DVD42 DVD48 1 R-7654 R-7654 R-7654 R-7654 FLUE INSULATION 2 17425 17425 17425 17425 FLUE INSULATION RETAINER 3 R-7566 R-7566 R-7566 R-7566...
Page 46 - PARTS VIEW
23552-1-0607 Page 46 1 2 3 4 5 6 7 14 15 15 30 33 34 35 31 44 45 41b 36 32 39 40b 48 50 37b 38 51 49 39 32 43 42 30 33 34 35 41a 31 36 37a 38 52 40a 52 22 23 24 26 27 22 25 26 29 28 14 13 13 13 13 8 9 10 11 12 16 19 20 21 17 18 DIRECT IGNITION BURNER ASSEMBL Y MILLIVOL T BURNER ASSEMBL Y 5 PIECE LOG...
Page 47 - FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION
23552-1-0607 Page 47 Attention : Install blower assembly before connecting gas inlet supply line Note : Junction box on right side of fireplace must be pre-wired at time of fireplace installation for use with blower assembly. It is recommended that an ON/OFF wall switch be installed that will activate...
Page 49 - JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
23552-1-0607 Page 49 CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY ...
Page 50 - DECORATIVE ACCESSORIES; ACCESSORIES
23552-1-0607 Page 50 The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62220-2623.Accessory Description ...
Page 51 - SERVICE NOTES
23552-1-0607 Page 51 Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number. When or...