Page 2 - ProLink; WARNING
1 ©2009, Micro Motion, Inc. All rights reserved. ELITE, ProLink, and the Micro Motion logo are registered trademarks of Micro Motion, Inc., Boulder, Colorado. MVD and MVD Direct Connect are trademarks of Micro Motion., Inc., Boulder, Colorado. Micro Motion is a registered trade name of Micro Motion,...
Page 4 - Install the ProLink II software; To install ProLink II software:
3 STEP 1. Install the ProLink II software To install ProLink II software: 1. Insert the ProLink II CD-ROM into the PC’s CD-ROM drive. 2. If the setup program does not start automatically, locate and run the SETUP.EXE file. The file is located in the root directory on the CD-ROM (e.g., D:\setup.exe, ...
Page 5 - Connect the PC to the transmitter; Connect the two leads of the signal converter to the appropriate; Transmitter terminals for ProLink II connections
4 STEP 2. Connect the PC to the transmitter 1. Connect the appropriate signal converter to your PC’s serial or USB port, using adapters as required. • For connections using the Bell 202 physical layer, use the Bell 202–RS-232 signal converter. • For connections using the RS-485 physical layer, use t...
Page 6 - Transmitter terminals for ProLink II connections (Continued)
5 Model 2400S with analog outputs 1 2 orHART clips Service port clips Model 2400S with DeviceNet Service port clips Model 2400S with PROFIBUS-DP Service port clips Series 3000 • Panel-mount with solder-tail or screw-type connectors c2 a2 c32 a32 c32 a32 c32 a32 • Panel-mount with I/O cables 14 15 24...
Page 7 - Add resistance if required. Many HART connections require added; Added resistance for ProLink II connections
6 3. Add resistance if required. Many HART connections require added resistance. See Table 2. For additional information, see the ProLink II manual or the transmitter manual. (5) Connecting directly to the core processor terminals is supported for sensor-mounted core processors (4-wire remote instal...
Page 8 - Configure the connection and connect; resistors in; Added resistance for ProLink II connections (Continued)
7 4. For Modbus network connections, ensure that ProLink II is the only Modbus master currently active on the network. There are additional methods for connecting ProLink II to your transmitter, including connecting over a network. See the ProLink II manual for complete information. STEP 3. Configur...
Page 10 - For all other connection types:; MVD Direct Connect auto-detection limits
9 • If you are connecting to any Model 2400S transmitter using the service port: - For point-to-point connections, you can use a service port connection type. - For multidrop network connections, you can use any RS-485 connection type and specify the transmitter’s Modbus address. The transmitter aut...
Page 11 - Model 2400S service port auto-detection limits; with output option codes 1 or 3.
10 Table 4. Model 2400S service port auto-detection limits Parameter Option Protocol Modbus RTU (8-bit)Modbus ASCII (7-bit) Address Responds to both:• Service port address (111) • Configured Modbus address (default=1) Baud rate Standard rates from 1200 to 38,400 Stop bits 0, 1 Parity Even, odd, none...
Page 12 - Connect; button. ProLink II will attempt to make the; here are always in effect.
11 6. Click the Connect button. ProLink II will attempt to make the connection. • If you are making a service port connection to a Model 1700/2700, Model 2400S, LFT field-mount, or Model 2200S transmitter, you can make the connection at any time. Table 6. Default communication values for RFT97xx and...
Page 13 - Converter; in the ProLink II
12 • If you are connecting to a Model 1500/2500, Series 3000, or LFT DIN rail mount transmitter, the RS-485 terminals are available in service port mode for 10 seconds after transmitter power-up. - If a service port connection is made during this interval, the terminals will remain in service port m...
Page 16 - Worldwide Headquarters
Micro Motion Europe Emerson Process ManagementNeonstraat 16718 WX EdeThe NetherlandsT +31 (0) 318 495 555 F +31 (0) 318 495 556 Micro Motion United Kingdom Emerson Process Management LimitedHorsfield WayBredbury Industrial EstateStockport SK6 2SU U.K.T +44 0870 240 1978 F +44 0800 966 181 Micro Moti...