Page 2 - Instruction Manual; Description
Instruction Manual D100325X012 1061 H & J Actuator October 2012 2 Table 1. Specifications Available Configuration Double-acting pneumatic piston rotary actuator for J throttling service when used with positioner or J on-off service when used with switching devices. Mounting adaptations include J...
Page 3 - Specifications; Emerson Process Management; Installation; WARNING
Instruction Manual D100325X012 1061 H & J Actuator October 2012 3 Specifications Specifications are shown in table 1 for 1061 actuators. Specifications for a given 1061 actuator as it originally comes from the factory are stamped on a nameplate (key 42, figure 6) attached to the actuator. Educat...
Page 4 - Table 4. Approximate Actuator Weights; Actuator Mounting; numbers are shown in figure 6.; Note
Instruction Manual D100325X012 1061 H & J Actuator October 2012 4 Table 3. Acceptable Shaft Diameters and Torque Limits for Actuators with J Mounting ACTUATOR SIZE COUPLING AVAILABILITY BY KEYED SHAFT DIAMETER TORQUE LIMIT FOR J MOUNTING mm Inches N S m Lbf S in 30 9.5 12.715.919.125.4 3/81/25/8...
Page 5 - appropriate fasteners, such as mounting cap screws.; CAUTION; Table 5. Keyway Alignment Information
Instruction Manual D100325X012 1061 H & J Actuator October 2012 5 Align the appropriate keyway with the keyway in the operated equipment shaft. If using a Fisher butterfly valve, align the appropriate keyway on the coupling with the valve shaft keyway indicated in table 5. Then, install the wood...
Page 6 - Figure 2. Fisher 1061 Mounting Dimensions
Instruction Manual D100325X012 1061 H & J Actuator October 2012 6 Figure 2. Fisher 1061 Mounting Dimensions H OR J MOUNTING ACTUATOR SIZE C E F H P Y mm 30 171 378 54 114 175 73 40 206 425 64 121 186 73 60 267 406 64 121 186 76 68 324 483 64 121 186 76 Inches 30 6.75 14.88 2.12 4.50 6.88 2.88 40...
Page 9 - Figure 3. Center of Gravity Dimensions
Instruction Manual D100325X012 1061 H & J Actuator October 2012 9 Figure 3. Center of Gravity Dimensions ACTUATOR SIZE CENTER OF GRAVITY DIMENSIONS X Y mm Inches mm Inches 30 54 2.12 137 5.4 40 64 2.50 112 4.4 60 64 2.50 91 3.6 68 64 2.50 155 6.1 19A1469-C A3250-2 X Y
Page 10 - Figure 5. Valve Shaft Coupling
Instruction Manual D100325X012 1061 H & J Actuator October 2012 10 Figure 4. Actuator Housing Construction Styles and Mounting Positions DESIRED ACTION OF HOUSING CONSTRUCTION TO SPECIFY Actuator Valve Body or Other Equipment Push Down to Open (PDTO) Clockwise to Close (1) Style A Counterclockwi...
Page 11 - Pressure Connections; Table 6. Wrench Sizes Required for Actuator Adjustment, Inches; Adjustment; equipment must be removed from the pipeline.
Instruction Manual D100325X012 1061 H & J Actuator October 2012 11 Pressure Connections 1. If a positioner is used, the pressure connections to the actuator are normally made at the factory. Actuators without positioners should have either a 4-way solenoid valve or a switching valve connected to...
Page 12 - each hex nut to the torque value listed in table 7.; Principle of Operation; provided. Such a device is not furnished as part of the actuator.; Maintenance; disassembly and replacement of parts.
Instruction Manual D100325X012 1061 H & J Actuator October 2012 12 3. Stroke the actuator until the left-hand threaded upper hex nut (key 71) can be reached through the access opening. Loosen the hex nut. 4. Perform one of the following: a. For push-down-to-close action (extending piston rod clo...
Page 13 - Before performing any maintenance operations:; loosening the packing box pipe plug.; Disassembly; from the top of the actuator.
Instruction Manual D100325X012 1061 H & J Actuator October 2012 13 WARNING Avoid personal injury or property damage from sudden release of process pressure or uncontrolled movement of parts. Before performing any maintenance operations: D Do not remove the actuator from the valve while the valve...
Page 14 - output shafts, refer to step 7 for this procedure.; Assembly; a travel stop (key 15) will be threaded into the cylinder flange.
Instruction Manual D100325X012 1061 H & J Actuator October 2012 14 6. For an actuator with an H mounting adaptation and a 22.2 through 38.1 mm (7/8 through 1-1/2 inch) output shaft, unscrew the cap screws (key 87) and remove the actuator from the operated equipment. Mark the orientation of the l...
Page 15 - Table 7. Bolting Torques
Instruction Manual D100325X012 1061 H & J Actuator October 2012 15 4. Apply lithium grease (key 93) to the inside wall of the cylinder, and then attach the cylinder assembly (key 1) to the cylinder flange with the cap screws (key 3). For size 30, 40, and 68 actuators only, replace the cylinder c...
Page 16 - Changing Actuator Mounting; Changing Styles
Instruction Manual D100325X012 1061 H & J Actuator October 2012 16 a. If no handwheel actuator is used, position the travel indicator (key 38) so that the markings on the travel indicator and travel indicator scale that were made in step 3 of the disassembly procedure are oriented correctly. The...
Page 17 - Changing Positions
Instruction Manual D100325X012 1061 H & J Actuator October 2012 17 b. Rotate the actuator housing 180 degrees, maintaining the appropriate position (1, 2, 3, or 4), and place the actuator onto the mounting yoke (key 23). c. Secure the actuator housing to the mounting yoke with the cap screws (ke...
Page 19 - Parts Ordering; from the following parts list when ordering replacement parts.; Repair Kits
Instruction Manual D100325X012 1061 H & J Actuator October 2012 19 a. Position the travel indicator (key 38) accordingly. Replace the cover (key 34), and secure it with the cap screws and washers (keys 35 and 76). If the holes in the cover and housing (key 21) do not align, use a regulated air s...
Page 23 - Figure 8. Partial View of Actuator with Bypass Valve
Instruction Manual D100325X012 1061 H & J Actuator October 2012 23 Figure 7. H Mounting for 44.5 or 50.8 mm (1-3/4 or 2-Inch) Keyed Equipment Shafts 39A2400-A A3249 ACTUATOR HOUSING Figure 8. Partial View of Actuator with Bypass Valve 54A5326-J SHT 2 A1755-1 BYPASS VALVE