Page 3 - Grid-to-chip protection for your critical investments; Services
110 10 8 9 6 6 6 11 3 No other organization can match thescope of Emerson Network Power’s product offerings and service reach, nor provide such complete grid-to-chip protection to ensure Business-Critical Continuity ™ for your technology investment. Grid-to-chip protection for your critical investme...
Page 4 - Contents
DC POWER 1 AC POWER 23 RACKS & INTEGRATED CABINETS 41 PRECISION COOLING 43 MONITORING 48 EMBEDDED POWER 54 Contents A Full Spectrum of Products of Emerson Network Power OUTSIDE PLANT 16
Page 6 - DC Power System
DC Power SystemConfi guration Matrix Large system Medium System Medium System Small System NetSure 801 PS48600-3/2900-X5 PS48250-1A/2900 PS48250-1B/2900 PS48250-1C/2900 PS48165/3200 Max. Power 348kW 34.8kW 14.5kW 14.5kW 14.5kW 9.6kW Voltage -48V -48V -48V -48V -48V -48V Max. Current 6000A 600A 250A 2...
Page 7 - Business-Critical ContinuityTM
NetSure 801 Stand-alone DC Power Series-48VDCup to 348kW Applications Large and medium switching offi ceLevel-1 transmission backbone lineGSM mobile switching offi ce, mobile tandem exchangeCDMA mobile switching offi ce, mobile tandem exchangeDC Internet data center System features Space saving, ...
Page 8 - AC distribution cabinet; DC distribution cabinet
DC distribution cabinet Features Local large LCD display Dual mains auto/manual switchoverFront access, Top / bottom cablingDC emergency lighting availableExpandable up to f ive AC cabinetsLightning proof and electric Compliance with IECROHS Compatible Affi liated Cabinet AC distribution cabi...
Page 21 - -48VDC Outdoor Power Cabinet
EPC48180/1800-FA -48VDC Outdoor Power Cabinet Dimensions And Weight model W × D × H, mm Weight (kg) Cabinet EPC48180/1800-FA 700 × 700 × 1700 150(rectifiers and batteries excluded) Features Capacity up to 10.44kW (180A @ 58V)Totally front access in favor of space-savingForced vent cooling systemPaten...
Page 22 - Outside Plant
EPC48120/1800-F -48VDC Outdoor Power Cabinet Dimensions And Weight model W × D × H, mm Weight (kg) Cabinet EPC48120/1800-F 600 × 630 × 1500 140(rectifi ers and batteries excluded) Features Capacity up to 6.96kW (120A @ 58V)Totally front access in favor of space-savingForced vent cooling systemIP45 fo...
Page 24 - Outdoor Battery Cabinet
EC200T/01 Outdoor Battery Cabinet Dimensions And Weight model Op. temp. W × D × H, mm Weight (kg) Cabinet EC150F/01 -10 ~ +55 ℃ 650 × 720 × 1400 100(batteries excluded) Features Cater up to 3 strings of 165Ah batteriesThermoelectricity cooler (TEC) insideInner temperature 5 ~ 15 ℃ below outside ambi...
Page 28 - AC Power
24 AC Power AC POWERConfi guration Matrix Small System Medium System Small System SERIES: US11R iTrust 31 iTrust 2G RATING: 1/2/3KVA 10/15/20KVA 3/6/9/12/15/18KVA MOUNTING: Tower/Rack Tower Tower/Rack I/O: 1-ph./1-ph. 3-ph./1-ph. 1-ph./1-ph. VOLTAGE: 220/230/240 (L-N) 380/220 220 (L-N) FREQUENCY: 50H...
Page 30 - US11-R Series Datasheet
US11-R Series Datasheet Model US11R-0010 US11R-0020 US11R-0030 US11R-0010L US11R-0020L US11R-0030L Nominal Power Rating at 0.7 PF 1KVA 2KVA 3KVA Input Parameters Rectifi er Type IGBT-based PFC(Power Factor Correction) Input Voltage 220Vac, 1-ph, 3-w Permissible Input Voltage Range 120-288Vac Permissi...
Page 32 - UH31 Series Datasheet
Model UH31-0100L UH31L-0150 UH31-0200L Nominal Power Rating at 0.7 PF 10KVA 15KVA 20KVA Input Parameters Rectifi er Type IGBT-based PFC (PF Corrected) Input Voltage 380Vac, 3-ph, 4-w Permissible Input Voltage Range 120Vac-276Vac Permissible Input Frequency Range 45-55Hz Input Power Factor at nominal ...
Page 33 - iTrust 2G Series UPS
iTrust 2G Series UPS Applications Industrial equipmentsSmall data centersComputing centersTelecommunication network hubs Features Modular Design- Plug & PlayN+X Redundancy - Higher reliabilityEasy and cheap expansion- Modules onlyOnline during maintenance- By simply replacing modulesSpace s...
Page 34 - iTrust 2G Series Datasheet
Models 3KVA 6KVA 9KVA 12KVA 15KVA 18KVA 2.4kW 4.8kW 7.2kW 9.6kW 12kW 14.4kW Model Name UP11-0180/12(12-Bay) UP11-0180/6(6-Bay) Input Parameters Rectifi er Type IGBT-based PFC Input Voltage 220Vac/1ph/3w Permissible Input Voltage Range 120-288Vac Permissible Input Frequency Range 45-55Hz Input Power F...
Page 35 - NX Series UPS
NX Series UPS Features Full digital control based on latest DSP Advanced Vector Control to Achieve Excellent Output Performance 'Green UPS' Design with High input power factor : 0.99 Low input current harmonic of less than : 3% Wide input window : 208-477V (L-L voltage) Parallel up to 6 units, No MS...
Page 36 - NX Series Datasheet
NX Series Datasheet Models Nxe 10 Nxe 15 Nxe 20 Nxa 30 Nxa 40 Nxa 60 Nxa 80 Nxa 100 Nxa 120 Nxa 140 Nxa 160 Nxa 200 Nominal Power Rating at 0.8 PF 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 140KVA 160KVA 200KVA Input Parameters Rectifi er Type IGBT-based Vector Controlled PFC (PF Correct...
Page 38 - Hipulse-U Series Datasheet
Hipulse-U Series Datasheet Hipulse UPS System Nominal Rating(KVA)(0.9pf)/kW 160/144 200/180 300/270 400/360 Rectifi er Type 6P 12P 6P 12P 6P 12P 6P 12P Input Voltage 380/400/415V(+/-15%)-3Ph-4w(rectifi er:290-498V) Frequency 50 or 60Hz +/-5% ITHD 4 to 9% with optional harmonic fi lter Power Factor 0.90...
Page 39 - Outdoor Series
Outdoor Series Special Features Natural cooling, high system reliability achievedDual conversion, online styleFully digital controlAuto start up when mains recoveredSuper wide input window (150-310V L-N)IP55 protection levelWide operation Temperature: -40-550CHigh level surge suppressor can be equip...
Page 40 - Outdoor Series Datasheet
Outdoor Series Datasheet Capacity 2KVA/3KVA Model Name UH11-0020LC, UH11-0030LC Input Rated Voltage 220Vac Voltage Range 150-310Vac Frequency 45 ~ 65Hz Power Factor > 0.98 Output Powe Factor 0.7 temp<5 ℃ 0.6 temp>10 ℃ Normal Voltage 220Vac 3% Frequency 50Hz Frequency Tracking Rate ≤1 Hz/s I...
Page 41 - Monitoring Solutions; Our Monitoring Solution Includes 5 Parts
Monitoring Solutions Features Java programming language. Web-based general-purpose monitoring softwareCompatible with multi operation systems, eg., Windows, Linux, Solaris, AIX, HP-UX, etc.Can log on via any computer on networkUPS by-layer management modeComplete history records for inquiry, statist...
Page 42 - SiteMonitor; Clear display of UPS operation status
SiteMonitor Click on UPS icons to check all operation indices and historical records online, with power status completely in hand Can name based on requirements and display by layer 2. Clear display of UPS operation status 1. Easy installation 3. Easy setting and adjustment U n d e r a u t h o r i z...
Page 44 - Auto-switch between Boost and Float Recharging; Temperature Compensation; Intelligent Battery Management
Auto-adaptable on EOD(End Of Discharge) Adjustment Different discharging solution for short backup-time system (<1h) and long backup-time system(>1h)The data of different models of batteries are stored in DSP and the UPS will detect the discharging current and automatically adjust the EOD for ...
Page 45 - RACKS & INTEGRATED CABINETS
Optimizing technology and performance needs for the global IT and telecom markets. We deliver standard and customized integrated cabinet solutions that meet unique and specifi c needs , from knürr and Liebert ® rack solutions for customer rooms of all sizes to knürr , MESA ® and Netspan™ 、 Matrix™ en...
Page 46 - Server Enclosure Systems; Rack system and IT total solution; Racks & Integrated Cabinets
Server Enclosure Systems Rack system and IT total solution Emerson Network Power Co.,Ltd. Launched the high reliability and high availability rack system and IT room total solution that suit the features of blade server based on its deep understanding in the user ’ s requirements for IT application ...
Page 48 - Precision cooling for Small Equipment Rooms; Precision Air Conditioning
Liebert DataMate3000(S) Precision cooling for Small Equipment Rooms DataMate3000 series air conditioning is developed by Emerson Network Power Co., Ltd. for small equipment rooms. The system provides 5.5kW , 7.5kW and 12.5kW cooling capacities and many confi guration options. Dimensions And Weight mo...
Page 49 - Liebert PEX; Precision cooling for medium/large equipment room
Liebert PEX Precision cooling for medium/large equipment room The Liebert PEX is the next generation precision air conditioning system from Emerson Network Power. The PEX is the latest in a long line of advanced products from the Liebert family designed to support business-critical applications. Fea...
Page 51 - Liebert XD
Liebert XD Flexible, Energy-Saving Cooling Solutions For High Heat Density Applications Applications IDCBlade servers High density servers and communications switchesRooms existing high heat density Dimensions And Weight model Total Capacity(kW) (24 ℃ /50%RH) Weight (kg) W × D × H, mm Main Unit...
Page 54 - Monitoring
Communication Solution of Monitoring System IP NetworkingFeatures: Using the availableTCP/IP network in siteSupportive of HTTP, TELNET, FTPRemote debugging and upgradeApplicable to:IDC room, MSC room, 3G base station, GPRS and CDMA site Server LAN IDU IDU IDU IDU IDU IDU E1 E1 BRG-POOL LAN IDU...
Page 59 - Mini Power System
GIE4805/2A/500-2 Mini Power System Key Features 1 U Height and designed for 19 ” racks Integrated Battery Low Voltage Disconnection function GIE4805/2A/500-2 Nominal system voltage: -48 VSystem rated output power @ - 54 V: 540 WRectifier rated output power @ - 54 V: 270 WDC distribution branch Bra...
Page 60 - Embedded Power
GEPS4820F/01-10/22-EN Mini Power System Key Features 1 U Height and designed for 19 ” racks Integrated LVD and priority load GEPS4820F/01-10/22-EN Nominal system voltage: - 48 VSystem rated output power @ - 54 V: 1600 WRectifi er rated output power @ - 54 V: 800 W DC distribution branch Branch 1 1...