Page 2 - Microsoft; All Rights Reserved.; Thin Web Server; Users; WARNING; Communication Address Forms
Thin Web Server Warnings © ASCO Power Technologies, L.P. 2008 Microsoft and Windows are registered trademarks of Microsoft Corporation. All Rights Reserved. The ASCO 5500 Catalog A5510 Thin Web Server (TWS) provides real-time monitoring and control of ASCO Automatic Transfer Switches and engine-gene...
Page 3 - Windows; Tip
Welcome Thin Web Server Who Should Use this Installation Manual This installation manual for the Thin Web Server should be used to assist individuals who will: • install and connect the Thin Web Server • configure the Thin Web Server with the setup program Prerequisites A working knowledge of Window...
Page 4 - Overview; Specifications; relative; Ground Connection; BTRY; comes on, this battery
1-1 Overview, Specifications, Ground Connection Thin Web Server Overview The ASCO 5500 Series Catalog A5510 Thin Web Server (TWS) provides real-time monitoring and control of ASCO Automatic Transfer Switches and engine-generator sets over the Internet or an intranet. The TWS also logs critical alarm...
Page 5 - Thin Web Server Mounting
Thin Web Server Mounting 2-1 Mount the Thin Web Server Refer to the outline and mounting drawing 771812 and mount the Thin Web Server vertically to a flat surface in a clean and dry location. If it is mounted in an enclosure it must provide adequate ventilation for cooling. Four 3/16” diameter mount...
Page 7 - Thin Web Server Connections; Connect the ATS Network; Standard 80o C; Connect the Power
Thin Web Server Connections 3-1 Connect the ATS Network Refer to Interface Wiring Diagram 771811. Use only the recommended communication cable listed below to connect the ATS network to the Thin Web Server. Standard 80º C Plenum Rated Belden 1419A, 9842, or 9829 Belden 89729 or 82729 Alpha 6202C or ...
Page 16 - Thin Web Server Setup Program – Serial Connection; Minimum PC Requirements for Setup and Browser Programs; Pentium; How to Install the Setup Program for Serial Connection; Thin Web Server Setup; Thin Web; Note; autorun
Thin Web Server Setup Program – Serial Connection 4-1 Minimum PC Requirements for Setup and Browser Programs The Thin Web Server requires the following minimum system configuration for the setup and browser program for serial connection: • Microsoft ® Windows ® 2000 or XP operating system • Personal...
Page 17 - Setup Program – Serial Connection Thin Web Server; Choose Destination Location; Select Program Folders; Next; Copying Windows Systems files ...; ThinWeb Server
Setup Program – Serial Connection Thin Web Server 4-2 3. The Choose Destination Location screen displays. Use the default destination directory. Click Next . 4. The Select Program Folders screen displays. Use the default directory in the Program Folder. Click Next . 5. The Copying Windows Systems fi...
Page 18 - Thin Web Server Setup Program – Serial Connection; How to start and setup the; software; CAUTION
Thin Web Server Setup Program – Serial Connection 4-3 How to start and setup the Thin Web Server software After installing the Thin Web Setup Program start the Thin Web Server software and set it up. 1. Double click the icon on the Windows desktop. 2. The Port Config tab displays first. Work with yo...
Page 19 - Setup Program – Serial Connection Thin Web Server; Alarms - Email Address; Email Address; Alarms - Engine Power Manager Setting
Setup Program – Serial Connection Thin Web Server 4-4 Alarms - Email Address Alarms - ATS Power Manager Setting Alarms - Engine PM Details 6. Click the Email Address lower tab. Then enter the e-mail addresses (up to 5) of the persons whom you want notified of the selected alarms. Double check each e...
Page 20 - Thin Web Server Setup Program – Serial Connection
Thin Web Server Setup Program – Serial Connection 4-5 10. Click the Logging tab. You can enable or disable historical data logging & alarm logging and change their default update interval. ; Historical data logging enabled or disabled flag Historical data logging update interval (15 to 30 minute...
Page 21 - Setup Program – Serial Connection Thin Web Server; Un-installing the program; Control Panel
Setup Program – Serial Connection Thin Web Server 4-6 Un-installing the program 1. Go to the Windows- desktop and click á Start on the taskbar. 2. Click Settings on the menu. 3. Click Control Panel . 4. In the Control Panel window, double click the Add/Remove Programs icon. 5. In the Add/Remove Prog...
Page 22 - Thin Web Server Setup – Ethernet Connection; Portable laptop computer with network card, running; section 8; and select the appropriate; Microsoft Internet Explorer; OK; Internet Explorer; NOTE
Thin Web Server Setup – Ethernet Connection 4-7 How to Establish Communication with the Thin Web Server via Ethernet Connection To set up the Thin Web Server via Ethernet connection, follow this procedure. Required items: • Portable laptop computer with network card, running Windows Xp , Windows 200...
Page 23 - Thin Web Server File Management Utilities; How to copy, delete, and view files in the; Serial Connection
Thin Web Server File Management Utilities 5-1 How to copy, delete, and view files in the Thin Web Server ( to update firmware, to update documentation ) Two file management utilities are included on the install CD. One is for Serial connection and the other is for Ethernet use. Serial Connection 1. ...
Page 24 - File Management Utilities Thin Web Server; RESET; Ethernet Connection; XP
File Management Utilities Thin Web Server 5-2 CAUTION Be sure that you are certain of file(s) to delete in the following procedure. 9. To start the file delete process click the Delete button once. A DOS window opens. Let the process complete; do not interrupt it. When finished, the DOS window will ...
Page 25 - Thin Web Server SSL Certificate & Private Key Files; How to install SSL certificate and private key files in the; Start the Thin Web Server setup program and connect to; Communication
Thin Web Server SSL Certificate & Private Key Files 6-1 How to install SSL certificate and private key files in the Thin Web Server Both the certificate and private key files have to be installed in the Thin Web Server root directory C:\. 1. Start the Thin Web Server setup program and connect to...
Page 26 - Thin Web Server Connectivity Module Configuration; Connectivity Module Configurator Program; How to Add Configuration Setting; Add Device; Click the; Save record
Thin Web Server Connectivity Module Configuration 7-1 Connectivity Module Configurator Program This utility is used to create, manage, upload, and dowload configuration settings to ASCO Connectivity Modules (only part no. 629800-xxx) that the Thin Web Server will be communicating with over LAN. How ...
Page 27 - Connectivity Module Configuration Thin Web Server; How to Edit Configuration Setting; Click; Edit device
Connectivity Module Configuration Thin Web Server 7-2 How to Edit Configuration Setting 1. Set the pointer to the configurator setting that you want to edit and then click Edit device button. 2. Edit mode only allows modification of name and location descriptions of ATSs with Group 1 Controller (Ser...
Page 28 - Thin Web Server Connectivity Module Configuration; Other Utilities; How to Reset Thin Web Server Serially
Thin Web Server Connectivity Module Configuration 7-3 4. When the process is done this message should appear. Click OK to continue. If message does not appear (wait), close the application and redo the process again. Other Utilities How to Reset Thin Web Server Serially 1. Launch the Thin Web Server...
Page 29 - How to View TWS MAC Address Thin Web Server; How to View the TWS MAC Address; On the menu bar, click; Utilities; This will post the message window as:; Yes; Make sure not to interrupt the process.
How to View TWS MAC Address Thin Web Server 7-4 How to View the TWS MAC Address 1. Launch the Thin Web Server setup program and connect it to the Thin Web Server. 2. On the menu bar, click Utilities , then click Extract TWS MAC ID . 3. This will post the message window as: Clck Yes to continue. 4. T...
Page 30 - Thin Web Server Client Settings; How to create an Ethernet TCP/IP network connection on a Windows; My Network Places; This device is working; Troubleshooter
Thin Web Server Client Settings 8-1 How to create an Ethernet TCP/IP network connection on a Windows ® 2000 ® PC 1. Right click on My Network Places then click Properties . 2. Right click on Local Area Connection icon. The following window will pop up. 3. If the device status indicates This device i...
Page 31 - Client Settings Thin Web Server; Properties
Client Settings Thin Web Server 8-2 5. Install Internet Protocol by clicking on Install button. If already installed highlight Internet Protocol (TCP/IP) and click on Properties . 6. If your PC is on the company network contact your IT personnel for appropriate settings. If you are connecting to an ...
Page 32 - Thin Web Server Client Settings
Thin Web Server Client Settings 8-3 How to create an Ethernet TCP/IP network connection on a Windows ® XP ® PC 1. Click start (lower left corner) and select Control Panel . 2. Click the Network and Internet Connections icon. 3. Click on Network Connections . 4. Right click on Local Area Connection i...
Page 33 - Client Settings Thin Web Server
Client Settings Thin Web Server 8-4 6. If the device status indicates This device is working properly. close this window and proceed to the next step. Otherwise follow the instructions as indicated in the Troubleshooter help to fix the problem. 7. Install Internet Protocol by clicking on Install but...
Page 34 - Thin Web Server Troubleshooting; Troubleshooting
Thin Web Server Troubleshooting Troubleshooting Symptom Possible Problem Possible Cause Action Prevention 1. Thin Web server (TWS) does not turn ON. . . – Check if you have the correct power supply. – Make sure the plug is connected properly to the supply outlet. 2. Thin Web Server keeps rebooting. ...
Page 39 - Communication Address Form; ) refer to Communication Interface Module
Communication Address Form Row No. Name of ATS or PM Location of ATS or PM ATS Serial Number ATS Catalog Number ATS Amps ATS Volts Address set in ATS Controller* Address set in Power Manager** (if provided) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Instructions: Fill in the information for each Automat...
Page 43 - INDEX; also see
Printed in U.S.A. © ASCO Power Technologies, L.P. 2008 All Rights Reserved. INDEX A Access Levels, 4-4 Alarms, 4-3 Alarm logging, 4-5 Ascii, 5-2 ATS alarm selection, 4-4 ATS Forms, back of manual ATS Power Manager Settings, 4-4 ATS Settings, 4-3 B Binary, 5-2 C Cable, Communication, 3-1 Catalog Numb...