Page 2 - Hazardous voltage can cause severe injury or death.; CAUTION
1 BEFORE YOU BEGIN This quick reference guide explains basic installation guidelines for mounting the Micro Motion ® Model 3300/3500 applications platform in a 19-inch (486,2 mm) rack. For information on I.S. applications, refer to Micro Motion ATEX, UL, or CSA installation instructions. For complet...
Page 3 - European installations; ATEX Installation Drawings and Instructions; Installation kit; One plug-in connector for power supply wiring; Choosing a location; Install the transmitter where ambient temperature is between
2 European installations This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this quick reference guide. Refer to the EC declaration of conformity for directives that apply to this product. The EC declaration of co...
Page 6 - neighboring unit or from the edge of the rack.
5 STEP 2. Installing guide rails and wiring connectors Guide rails Positions of guide rails and wiring connectors are indicated in Figure 3, page 6. Centers of guide rails should be 27 HP (27 TE) apart, for example, at 1 HP (TE) and 28 HP (TE). Wiring connectors The applications platform is shipped ...
Page 7 - Positions of guide rails and wiring connectors; Slide the Model 3300/3500 into the rack. Make sure the pins on the
6 Figure 3. Positions of guide rails and wiring connectors STEP 3. Installing the Model 3300/3500 in the rack 1. Align the Model 3300/3500 with the guide rails. 2. Slide the Model 3300/3500 into the rack. Make sure the pins on the back panel make contact with the wiring connectors. 3. Tighten the su...
Page 8 - Connecting input and output wiring; Ground the shields at a single point only.; Input/output wiring terminal card
7 STEP 4. Connecting input and output wiring Connect input and output wiring to the appropriate terminals on the input/output wiring connector, which is the far right connector. Refer to Table 1 and to the card that is inserted into the sleeve on the top panel (shown in Figure 4). • Use 24 to 16 AWG...
Page 10 - Cable Preparation and Installation Guide; Connecting power supply wiring; Connect the ground wire to the middle terminal.
9 5. At the transmitter: a. Connect the color-coded wires to the appropriate terminals. To identify the terminals, refer to Figure 5, page 8. No bare wires should remain exposed. b. If using shielded or armored cable, connect the cable braid to the rear stud, as described in Micro Motion’s 9-Wire Fl...
Page 11 - Power supply wiring terminals
10 Figure 6. Power supply wiring terminals Power supply wiring terminals Terminal designations for AC power Terminal designations for DC power
Page 12 - Micro Motion; Micro Motion Europe; Worldwide Headquarters
Micro Motion TM Micro Motion Europe Emerson Process ManagementWiltonstraat 303905 KW VeenendaalThe NetherlandsT +31 (0) 318 495 670 F +31 (0) 318 495 689 Micro Motion United Kingdom Emerson Process Management LimitedHorsfield WayBredbury Industrial EstateStockport SK6 2SU U.K.T 0800 966 180 F 0800 9...