Page 4 - Features; Lamp: Philips PLATINUM 5R
2 Thank you for your patronage. We are confident that our excellent products and service can satisfy you. For your own safety, please read this user manual carefully before installing the device.In order to install , operate, and maintain the lighting safety and correctly. We suggest that the instal...
Page 5 - Software-upload by optional accessory via DMX line; Overview; SAFETY INSTRUCTIONS; 2)Lamp bracketrear metal panel
3 · Stepless frost, 0%~100% linear change frost · Strobe/shutter: High speed shutter, 0-13 Hz or random strobe · Control board with full color LCD graphic display and touch-keyboard · Auto-program: 7 pre-built programs can be selected. · Software-upload by optional accessory via DMX line Overview SA...
Page 7 - a) Installing or replacing the lamp
5 GENERAL GUIDELINES This device is a lighting effect for professional use on stages, in discotheques, theatres, etc., the device was designed for indoor use only. This fixture is only allowed to be operated with the max alternating current which stated in the technical specifications in the last pa...
Page 8 - is underneath. Carefully remove the metal plate.; b) Mounting the device
6 Before replacing the lamp let the lamp cool down, because during operation, the lamp canreach very high temperature.During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a cloth to handle the lamps during insertion and removal.Do not install lamps with a hig...
Page 9 - weight for 1 hour without any harming deformation.
7 weight for 1 hour without any harming deformation. The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety rope. Never stand directly below the device when mounting, removing or servicing the fixture. The operator has to make sure the safety relating ...
Page 10 - Installation via the Omega holders; the middle of the bracket.; DMX-512 control connection
8 Installation via the Omega holders a) Fixed the clamp on the bracket by tighten up the M12 screw on the bracket to the Ф 13 hole in the middle of the bracket. b) Insert the quick-lock fasteners of the first Omega holder into the respective holes on the bottom of the device. Tighten the quick-lock ...
Page 11 - DMX-512 connection with DMX terminator; Projector DMX start address selection; Address 1 Address 14 Address27
9 DMX-512 connection with DMX terminator For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical n...
Page 12 - Control Board
10 to 1, the second unit to 14(13 + 1), the third to 27 (13 + 14), and so on. Control Board The Control Board offers several features: you can simply set the starting address , run the pre-programmed program or make a reset. The main menu is accessed by pressing the -button until the display starts ...
Page 14 - Main Menu Functions; “Set DMX Address” - DMX address setting –; This function is used to set or adjust; “Value Display” - Display the DMX 512 value of each channel
12 rs Mo de Set Edit User Mode Edit User Mode Max Channel = XXPAN = CH01 : Max Channel = XXPAN = CH01 : Max Channel = XXPAN = CH01 : Max Channel = XXPAN = CH01 : Max Channel = XXPAN = CH01 : Max Channel = XXPAN = CH01 : Preset User modes Edit Pro gra m Select Programs Select Programs Auto Pro Part 1...
Page 16 - counter should be reset after every lamp change.; Lamp Off Time; lamp can be replaced at the end of it’s recommended duty cycle.; Software version
14 counter should be reset after every lamp change. Lamp Off Time This function displays the running time of the lamp from the last power on. The display shows “XXXX”, where “XXXX” represents the number of hours the lamp has been running since it was last struck. This counter is automatically reset ...
Page 21 - Test Channel –; This menu function allows the user to select each individual; Calibrate values –; This function should only be performed by a qualified technician.; User mode –; defined modes that are created in the previous function.
19 Effect Adjust: Test Channel – This menu function allows the user to select each individual fixture channel and test it’s function independently from the control board. Lamp adjustment (manual control) – This function readies the fixture for lamp optimization in a simple single step procedure. Thi...
Page 22 - This function allows the user to edit the built-in programs.; Edit Scenes –; The Platinum Spot 5R features an integrated DMX recorder. Pre-
20 external DMX controller. For detailed instructions on how to complete this task please see Section 12/ Page 39. Select program – This function allows the user to select one of ten of the user defined built-in programs. This program is then accessed in “Function Mode” under “Program Run.” Edit pro...
Page 23 - Pan Fine 16bit
21 INSTRUCTIONS ON USE: DMX channel´s functions and their values (16 DMX channels): DMX channel´s functions and their values (16 DMX channels): DMX channel´s functions and their values (16 DMX channels): DMX channel´s functions and their values (16 DMX channels): DMX channel´s functions and their va...
Page 25 - Fine Dimmer intensity:; ERROR MESSAGE
23 10 8 12 Dimmer intensity: 10 8 12 0-255 Intensity 0 to 100% 13 Fine Dimmer intensity: 13 0-255 Dimmer intensity fine 11 9 14 Frost: 11 9 14 0-127 Disable frost 11 9 14 128-255 Enable frost 12 10 15 Speed Pan/Tilt movement: 12 10 15 0-225 max to min speed 12 10 15 226-235 blackout by...
Page 26 - Color wheel Er; CLEANING AND MAINTENANCE; accumulation of dust.
24 some error in channel 1. If there are some errors on channel 1, channel 5, channel 6 at the same time, you may see the error message “Err channel is Color wheel”, “Err channel is Pan movement”, “Err channel is Tilt movement” flash repeated for 2 times, and then the fixture will generate a second ...
Page 27 - TECHNICAL SPECIFICATIONS; Packing dimensions
25 We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or solvents. There are no serviceable parts inside the device except for the lamp. Please refer to the instructions under “Installation instructions”. Should you need any spare parts, please or...