Edimax AC-M3000 - Manuals
Edimax AC-M3000 – Manual in PDF format online.
Manuals:
Manual Edimax AC-M3000
Summary
The product you have purchased and the setup screen may appear slightly different from those shown in this QIG. For more detailed information about this product, please refer to the User's Manual on the CD-ROM. Software and specifications subject to change without notice. Please visit our web site f...
Edimax AC-M3000/AC-M1000 User’s Manual i Table of Contents 1. Before You Start ............................................................................................................................3 1.1 Preface ......................................................................................
Edimax AC-M3000/AC-M1000 User’s Manual ii 4.3.4 Template Settings ........................................................................................................................................95 4.3.5 Firmware Management ........................................................................
Edimax AC-M3000/AC-M1000 User’s Manual 3 1. Before You Start 1.1 Preface This manual is for Hotspot owners, SMBs, or administrators in enterprises to set up network environment using Edimax AC-M3000/AC-M1000. It contains step by step procedures and graphic examples to guide MIS staff or individuals ...
Edimax AC-M3000/AC-M1000 User’s Manual 4 2. System Overview 2.1 Introduction of Edimax AC-M3000 Edimax AC-M3000 is a Network Access Controller, specially designed for the small scaled wireless and wired network management and access control. The major functional areas include user management, access...
Edimax AC-M3000/AC-M1000 User’s Manual 5 2.3 Specification 2.3.1 Hardware Specification y General Form Factor: Mini-desktop Dimensions (W x D x H): 243 mm x 150 mm x 45.5 mm Weight: 1.4 Kg Operating Temperature: 0 ~ 45 ℃ Storage Temperature: 0 ~ 65 ℃ Power: 110~220 VAC, 50/60 Hz Ethernet Interfaces:...
Edimax AC-M3000/AC-M1000 User’s Manual 6 Supports DoS attack protection Supports user Black List Allows user identity plus MAC address authentication for local accounts y User Management Supports up to 120 concurrent users for AC-M3000 (50 concurrent users for AC-M1000) Provides 500 local accounts f...
Edimax AC-M3000/AC-M1000 User’s Manual 7 Built-in billing profiles for on-demand accounts Enables session expiration control for on-demand accounts by time (hour) and data volume (MB) Provides billing report on screen for on-demand accounts Detailed per-user traffic history based on time and data vo...
Edimax AC-M3000/AC-M1000 User’s Manual 8 3. Base Installation 3.1 Hardware Installation 3.1.1 System Requirements y Standard 10/100BaseT network cables with RJ-45 connectors y All PCs need to install the TCP/IP network protocol 3.1.2 Package Contents The standard package of Edimax AC-M3000 includes:...
Edimax AC-M3000/AC-M1000 User’s Manual 9 3.1.3 Panel Function Descriptions Front Panel y LED: There are four kinds of LED, Power, Status, WAN and LAN, to indicate different status of the system. y WAN1/WAN2: The two WAN ports are connected to a network which is not managed by the Edimax AC-M3000 sys...
Edimax AC-M3000/AC-M1000 User’s Manual 10 3.1.4 Installation Steps Please follow the following steps to install Edimax AC-M3000: 1. Connect the 12V power adapter to the power socket on the rear panel. The Power LED should be on to indicate a proper connection. 2. Connect an Ethernet cable to the WAN...
Edimax AC-M3000/AC-M1000 User’s Manual 11 3.2 Software Configuration 3.2.1 Quick Configuration There are two ways to configure the system: using Configuration Wizard or changing the setting by demands manually. The Configuration Wizard has 6 steps providing a simple and easy way to guide you through...
Edimax AC-M3000/AC-M1000 User’s Manual 12 Edimax AC-M3000 supports three kinds of account interface. You can log in as admin , manager or operator . The default username and password as follows. Admin: The administrator can access all area of the Edimax AC-M3000. User Name: admin Password: 1234 Mana...
Edimax AC-M3000/AC-M1000 User’s Manual 14 5. Configuration Wizard A welcome page that briefly introduces the 6 steps will appear. Click Next to begin. y Step 1. Change Admin’s Password Enter a new password for the admin account and retype it in the Verify Password field (twenty-character is the maxi...
Edimax AC-M3000/AC-M1000 User’s Manual 16 ¾ PPPoE Client: Set PPPoE Client’s Information Enter the “Username” and “Password” provided by the ISP. Click Next to continue. y Step 5. Set Authentication Methods Enter an identified name as the postfix name in the Postfix field (e.g. Local), select a poli...
Edimax AC-M3000/AC-M1000 User’s Manual 19 Caution: During each step of the wizard, if you want to go back to modify the setting, please click the Back button to go back to the previous step. 3.2.2 User Login Portal Page To login from the login portal page via the controlled port, the user has to be ...
Edimax AC-M3000/AC-M1000 User’s Manual 20 3. When an on-demand user logs in successfully, the following Login Successfully page will appear. There is an extra line showing “Remaining usage” and a “Redeem” button on the button. y Remaining usage: Show the remaining time or data volume that the on-dem...
Edimax AC-M3000/AC-M1000 User’s Manual 21 4. Web Interface Configuration This chapter will guide you through further detailed settings. The following table is the UI and functions of Edimax AC-M3000. OPTION System Configuration User Authentication AP Management Network Configuration Utilities Status...
Edimax AC-M3000/AC-M1000 User’s Manual 22 4.1 System Configuration This section includes the following functions: Configuration Wizard , System Information , WAN1 Configuration , WAN2 & Failover , LAN Port Roles , Controlled Configuration and Uncontrolled Configuration . 4.1.1 Configuration Wiza...
Edimax AC-M3000/AC-M1000 User’s Manual 23 4.1.2 System Information Most of the major system information about Edimax AC-M3000 can be set here. Please refer to the following description for each field:
Edimax AC-M3000/AC-M1000 User’s Manual 24 y System Name: Set the name of the system or use the default. y Device Name: FQDN (Fully-Qualified Domain Name). This is used as the domain name used in login page. For example, if Device Name=ashop.com, the URL of login page will be https://ashop.com/loginp...
Edimax AC-M3000/AC-M1000 User’s Manual 25 time into these fields. 4.1.3 WAN1 Configuration There are 4 connection types for the WAN1 Port: Static IP Address , Dynamic IP Address , PPPoE Client and PPTP Client .
Edimax AC-M3000/AC-M1000 User’s Manual 26 y Static IP Address: Manually specifying the IP address of the WAN1 Port is applicable for the network environment where the DHCP service is unavailable. The fields with red asterisks are required to be filled in. IP Address: the IP address of the WAN1 port....
Edimax AC-M3000/AC-M1000 User’s Manual 27 y PPTP Client: Point to Point Tunneling Protocol is a service that applies to broadband connection used mainly in Europe and Israel. Select Static to specify the IP address of the PPTP Client manually or select DHCP to get the IP address automatically. The f...
Edimax AC-M3000/AC-M1000 User’s Manual 31 4.1.6 Controlled Configuration The clients of Controlled Port need authentication before they can access the network. In this section, you can set the related configuration of Controlled Port. y Controlled Operation Mode: Choose one of the two modes, NAT mod...
Edimax AC-M3000/AC-M1000 User’s Manual 32 DHCP Scope: Enter the “Start IP Address” and the “End IP Address” . Start IP Address means the fist IP address of the DHCP scope. End IP Address means the last IP address of the DHCP scope. These two settings define the IP address range that will be assigned...
Edimax AC-M3000/AC-M1000 User’s Manual 33 Enable DHCP Relay: The DHCP Server IP address must be entered when this function is enabled. For more details about DHCP Relay, please see Appendix G—DHCP Relay. 4.1.7 Uncontrolled Configuration The clients of Uncontrolled Port don’t need authentication befo...
Edimax AC-M3000/AC-M1000 User’s Manual 36 4.2 User Authentication This section includes the following functions: Authentication Configuration , Black List Configuration , Policy Configuration , and Additional Configuration . 4.2.1 Authentication Configuration This function is used to configure the s...
Edimax AC-M3000/AC-M1000 User’s Manual 38 y On-demand User: When the customers need to use wireless Internet service in stores, they have to get printed receipts with usernames and passwords from the store to log in the system for wireless access. There are 2000 On-demand User accounts available. Se...
Edimax AC-M3000/AC-M1000 User’s Manual 39 Users List: Click to enter the On-demand Users List page. In the On-demand Users List , detailed information will be shown here. ¾ Search: Enter a keyword of a username to be searched in the text field and click this button to perform the search. All usernam...
Edimax AC-M3000/AC-M1000 User’s Manual 40 ¾ Status: Select to enable or disable this billing plan. ¾ Type: Set the billing plan by “Volume” (the maximum volume allowed is 9999999 Mbytes) or “Time” (the maximum time allowed is 999 hours and 59 minutes). ¾ Expired info: This is the duration of time th...
Edimax AC-M3000/AC-M1000 User’s Manual 41 Pressing the Create button for the desired plan, an on-demand user will be created, then click Printout to print a receipt which will contain this on-demand user’s information. There are 2000 on-demand user accounts available. Billing Report: Click this to e...
Edimax AC-M3000/AC-M1000 User’s Manual 42 Summary report page, the administrator can get a complete report or a report within a particular period. ¾ Report All: Click this to get a complete report including all the on-demand records. This report shows the total expenses and individual accounting of ...
Edimax AC-M3000/AC-M1000 User’s Manual 43 4.2.1.1 Authentication Method – Local User Setting Choose Local User in the Authentication Method field, the hyperlink besides the drop-down menu will become to Local User Setting . Click the hyperlink of Local User Setting for further configuration. y Edit ...
Edimax AC-M3000/AC-M1000 User’s Manual 44 VPN Termination . Click Apply to save all the settings after finishing to add users. Upload User: Click this to enter the Upload User interface. Click the Browse button to select the text file for uploading the user accounts. Then click Submit to complete th...
Edimax AC-M3000/AC-M1000 User’s Manual 45 The uploading file should be a text file and the format of each line is "ID, Password, MAC, Policy, Remark, IPSec" without the quotes. There must be no spaces between the fields and commas. The MAC field could be omitted but the trailing comma must b...
Edimax AC-M3000/AC-M1000 User’s Manual 46 Refresh: Click this to renew the Users List page. Search: Enter a keyword of a username that you want to search and click this button to perform the search. All
Edimax AC-M3000/AC-M1000 User’s Manual 47 usernames matching the keyword will be listed. Del All: This will delete all users at once. Delete: This will delete a specific user individually. Edit User: If you want to edit the content of an individual user account, click the username of the desired use...
Edimax AC-M3000/AC-M1000 User’s Manual 48 Click the hyperlink of Radius Client List to enter the Radius Client Configuration page. Choose the desired type, Disable , Roaming Out or 802.1x and key in the related data and then click Apply to complete the configurations. Radius Roaming Out: When Radius...
Edimax AC-M3000/AC-M1000 User’s Manual 54 y Server IP address: Enter the server IP address of the domain controller. y Transparent Login: If the function is enabled, users will log into Edimax AC-M3000 automatically when they log into the Windows domain and the IP of NT Domain Server should be added...
Edimax AC-M3000/AC-M1000 User’s Manual 55 After entering the usernames in the Username field and the related information in the Remark field (not required). Click Apply to save the settings.
Edimax AC-M3000/AC-M1000 User’s Manual 56 If the administrator wants to remove a user from the black list, just select the user’s “Delete” check box and then click the Delete button to remove that user from the black list. 4.2.3 Policy Configuration Each policy has three profiles, Firewall Profile ,...
Edimax AC-M3000/AC-M1000 User’s Manual 57 y Firewall Profile Click the hyperlink of Setting for Firewall Profile , the Firewall Profile page will appear. Click the numbers of Filter Rule Item to edit individual rules and click Apply to save the settings. The rule status will show on the list. Check ...
Edimax AC-M3000/AC-M1000 User’s Manual 58 Rule Item: This is the rule selected. Rule Name: The rule name can be changed here. The rule name can be set to easily identify, for example: “from file server” , “HTTP request” or “to web” , etc. Enable this Rule: After checking this function, the rule will...
Edimax AC-M3000/AC-M1000 User’s Manual 59 Specific Default Route Enable: Click to enable the setting of specific default route. Default Gateway: There are 3 methods of the default gateway that Specific Default Route supports. Select WAN1 Default Gateway to set WAN1 as the default gateway. Select WAN...
Edimax AC-M3000/AC-M1000 User’s Manual 60 y Total Bandwidth Select the bandwidth from the drop-down menu. It’s the total bandwidth the users under this particular policy need to share. y Individual Maximum Bandwidth Select the bandwidth from the drop-down menu. It’s the most bandwidth an individual ...
Edimax AC-M3000/AC-M1000 User’s Manual 61 particular policy, which cannot exceed the value for Total Bandwidth . y Individual Request Bandwidth Select the bandwidth from the drop-down menu. It’s the requested bandwidth for a user under this particular policy, which cannot exceed the value for Indivi...
Edimax AC-M3000/AC-M1000 User’s Manual 62 Interim Update: The system will update the users’ current status and usage according to this time periodically. y Upload File 1. Certificate: The administrator can upload new private key and customer certification. Click the Browse button to select the file ...
Edimax AC-M3000/AC-M1000 User’s Manual 63 c. Choose Uploaded Page and upload a login page. Click the Browse button to select the file to upload. Then click Submit to complete the upload process.
Edimax AC-M3000/AC-M1000 User’s Manual 64 After the upload process is completed, the new login page can be previewed by clicking Preview button at the bottom. The user-defined login page must include the following HTML codes to provide the necessary fields for username and password.
Edimax AC-M3000/AC-M1000 User’s Manual 65 I f the user-defined login page includes an image file, the image file path in the HTML code must be the image file you will upload. Then, enter or browse the filename of the images to upload in the Upload Images field on the Upload Images Files page and the...
Edimax AC-M3000/AC-M1000 User’s Manual 66 “Preview” can be clicked to see the uploaded page. If a user checks “I agree” and clicks Next , then he/she is prompted to fill in the login name and password. If a user checks “I disagree” and clicks Next , a window will pop up to tell user that he/she cann...
Edimax AC-M3000/AC-M1000 User’s Manual 67 d. Choose the External Page selection and get the login page from the specific website. Enter the website address in the “External Page Setting” field and then click Apply . After applying the setting, the new login page can be previewed by clicking Preview ...
Edimax AC-M3000/AC-M1000 User’s Manual 68 3. Logout Page: The administrator can apply customized logout page here. The process is similar to that of Login Page. The different part is the HTML code of the user-defined logout interface must include the following HTML code that the user can enter the u...
Edimax AC-M3000/AC-M1000 User’s Manual 72 and click Delete to delete the file. d. Choose the External Page selection and you can get the login success page e from the specific website. Enter the website address in the External Page Setting field and then click Apply . After applying the setting, the...
Edimax AC-M3000/AC-M1000 User’s Manual 73 c. Choose Uploaded Page and you can get the Login Success Page Section for On-Demand Users . Click the Browse button to select the file for the login success page for On-Demand. Then click Submit to complete the upload process.
Edimax AC-M3000/AC-M1000 User’s Manual 79 y Enhance User Authentication: With this function enabled, only the users with their MAC addresses in this list can log into Edimax AC-M3000. There will only be 40 users allowed in this MAC address list. User authentication is still required for these users....
Edimax AC-M3000/AC-M1000 User’s Manual 81 After adding an AP: Check any AP and click the button below to Reboot , Enable , Disable and Delete the checked AP. Click Apply Template to select one template to apply to the AP.
Edimax AC-M3000/AC-M1000 User’s Manual 82 y AP Name Click AP Name and enter the interface about related settings. There four kinds of settings, General Settings , LAN Interface Setting , Wireless Interface Setting and Access Control Setting . Click the hyperlink of each individual setting to have fu...
Edimax AC-M3000/AC-M1000 User’s Manual 83 Password and Remark here if desired. Firmware information can also be viewed here. ¾ LAN Setting: Click LAN to enter the LAN Setting interface. Input the data of LAN including IP address , Subnet Mask and Default Gateway of AP. ¾ Wireless LAN: Click Wireless...
Edimax AC-M3000/AC-M1000 User’s Manual 84 Properties y SSID: The SSID is the unique name shared among all devices in a wireless network. The SSID must be the same for all devices in the wireless network. It is case sensitive and has a maximum length of 32 bytes. y SSID Broadcast: Select this option ...
Edimax AC-M3000/AC-M1000 User’s Manual 85 y CTS Protection: The default value is Disable . When select “Enable” , a protection mechanism will decrease collision probability when many 802.11g devices exist simultaneously. However, performance of the 802.11g devices may decrease. y Fragment Threshold:...
Edimax AC-M3000/AC-M1000 User’s Manual 87 y WPA Mixed: If using TKIP and AES encryption type at the same time is desired, choose this security type. Select 802.1x or WPA-PSK security type and enter the related information below. ¾ Access Control: In this function, when the status is Enabled , only t...
Edimax AC-M3000/AC-M1000 User’s Manual 89 ¾ System Status: The table shows the information about AP Name , AP Status and Last Reporting Time . ¾ LAN Status: The table shows the information about IP Address , Subnet Mask and Gateway .
Edimax AC-M3000/AC-M1000 User’s Manual 90 ¾ Wireless LAN Status: The table shows all of the related wireless information. ¾ Access Control Status: The table shows the status of MAC of clients under the control of the AP. ¾ Associated Client Status: The table shows the clients connecting to the AP an...
Edimax AC-M3000/AC-M1000 User’s Manual 91 4.3.2 AP Discovery Use this function to detect and manage all the supported APs in the network segments. y To discover AP manually, please fill in the required data. ¾ Interface: Check Uncontrolled or/and Controlled and enter the Base IP and Pool Size (the d...
Edimax AC-M3000/AC-M1000 User’s Manual 92 for APs and then click Discover again. For the desired AP, input the desired name and password, select one template to apply, select the check box, and click Add to add the AP to the AP List. (About the template, please see 4.3.4 Template Settings ). When th...
Edimax AC-M3000/AC-M1000 User’s Manual 93 Click Configuring to go to the related configuration. For the details, please refer to 4.3.1 AP List . y Auto-Discovery: Click Configure to enter the Auto-Discovery interface and have further configuration.
Edimax AC-M3000/AC-M1000 User’s Manual 94 The Interface and AP Access configuration is the same as the settings mentioned above. Click “Configure” button for more Auto-Discovery functions. A selection known as “ Interval ” can be selected from the drop-down box, and the system will scan periodically...
Edimax AC-M3000/AC-M1000 User’s Manual 95 4.3.4 Template Settings Template is a model that can be copied to every AP without having to configure the each AP individually. There are three templates provided. Click Edit to go to configuration. Except configuring all the template setting, copy the conf...
Edimax AC-M3000/AC-M1000 User’s Manual 99 4.4 Network Configuration This section includes the following functions: Network Address Translation , Privilege List , Monitor IP List , Walled Garden List , Proxy Server Properties and Dynamic DNS , IP Mobility and VPN Termination . 4.4.1 Network Address T...
Edimax AC-M3000/AC-M1000 User’s Manual 102 4.4.2 Privilege List Edimax AC-M3000 provides two privilege lists, Privilege IP Address List and Privilege MAC Address List . In the Privilege List function, the administrator can add desired IP addresses and MAC addresses in these lists. The IP addresses a...
Edimax AC-M3000/AC-M1000 User’s Manual 106 y External Proxy Server: Under the Edimax AC-M3000 security management, the system will match the proxy setting of External Proxy Server list to the clients’ proxy setting when clients’ have proxy setting in their browsers. If there is no matching, the clie...
Edimax AC-M3000/AC-M1000 User’s Manual 107 4.4.6 Dynamic DNS Edimax AC-M3000 provides a convenient DNS function to translate a domain name to the corresponding IP address of WAN port that helps the administrator memorize and connect to WAN port. If the DHCP is activated at WAN port, this function wi...
Edimax AC-M3000/AC-M1000 User’s Manual 110 Caution: If the administrator’s password is lost, the administrator’s password still can be changed through the text mode management interface on the serial port, console/printer port. 4.5.2 Backup/Restore Settings This function is used to backup/restore th...
Edimax AC-M3000/AC-M1000 User’s Manual 111 y Backup current system settings: Click Backup to create a .db database backup file and save it on disk. y Restore system settings: Click Browse to search for a .db database backup file created by Edimax AC-M3000 and click Restore to restore to the same set...
Edimax AC-M3000/AC-M1000 User’s Manual 112 Warning: 1. Firmware upgrade may cause the loss of some of the data. Please refer to the release notes for the limitation before upgrading the firmware. 2. Please restart the system after upgrading the firmware. Do not power on/off the system during the upg...
Edimax AC-M3000/AC-M1000 User’s Manual 113 4.6 Status This section includes System Status , Interface Status , Current Users , Traffic History , and Notification Configuration to provide system status information and online user status. 4.6.1 System Status This section provides an overview of the sy...
Edimax AC-M3000/AC-M1000 User’s Manual 114 The description of the table is as follows: Item Description Current Firmware Version The present firmware version of Edimax AC-M3000 System Name The system name. The default is Edimax AC-M3000
Edimax AC-M3000/AC-M1000 User’s Manual 116 The description of the table is as follows. Item Description MAC Address The MAC address of the WAN1 port. IP Address The IP address of the WAN1 port. WAN1 Subnet Mask The Subnet Mask of the WAN1 port.
Edimax AC-M3000/AC-M1000 User’s Manual 117 MAC Address The MAC address of the WAN2 port. IP Address The IP address of the WAN2 port. WAN2 Subnet Mask The Subnet Mask of the WAN2 port. Mode The mode of the controlled port. MAC Address The MAC address of the controlled port. IP Address The IP address ...
Edimax AC-M3000/AC-M1000 User’s Manual 118 4.6.4 Traffic History This function is used to check the history of Edimax AC-M3000. The history of each day will be saved separately in the DRAM for 3 days. Caution: Since the history is saved in the DRAM, if you need to restart the system and also keep th...
Edimax AC-M3000/AC-M1000 User’s Manual 121 4.7 Help On the screen, the Help button is on the upper right corner. Click Help to the Online Help window and then click the hyperlink of the items to get the information.
Edimax AC-M3000/AC-M1000 User’s Manual 122 5. Appendix A – Console Interface Via this port to enter the console interface for the administrator to handle the problems and situations occurred during operation. 1. To connect the console port of Edimax AC-M3000, you need a console, modem cable and a te...
Edimax AC-M3000/AC-M1000 User’s Manual 123 y Utilities for network debugging The console interface provides several utilities to assist the Administrator to check the system conditions and to debug any problems. The utilities are described as follow: ¾ Ping host (IP): By sending ICMP echo request to...
Edimax AC-M3000/AC-M1000 User’s Manual 124 system also supports the SSH online connection for the setup. When using a null modem to connect to the system console, we do not need to enter administrator’s password to enter the console management interface. But connecting the system by SSH, we have to ...
Edimax AC-M3000/AC-M1000 User’s Manual 125 6. Appendix B – Network Configuration on PC After Edimax AC-M3000 is installed, the following configurations must be set up on the PC: Internet Connection Setup and TCP/IP Network Setup . y Internet Connection Setup If the Internet Connection of this client...
Edimax AC-M3000/AC-M1000 User’s Manual 126 3. Click Next when Welcome to the New Connection Wizard screen appears. 4. Choose “Connect to the Internet” and then click Next . 5. Choose “Set up my connection manually” and then click Next .
Edimax AC-M3000/AC-M1000 User’s Manual 127 6. Choose “Connect using a broadband connection that is always on” and then click Next . 7. Finally, click Finish to exit the Connection Wizard . Now, you have completed the setup.
Edimax AC-M3000/AC-M1000 User’s Manual 130 7. Appendix C – IPSec VPN Edimax AC-M3000 has equipped with IPSec VPN feature starts from release version v1.00. To fully utilize the nature supported IPSec VPN by Microsoft Windows XP SP2(with patch) and Windows 2000 operating systems, Edimax AC-M3000 impl...
Edimax AC-M3000/AC-M1000 User’s Manual 131 During the first-time login to Edimax AC-M3000, Internet Explorer will ask user to download the ActiveX component of IPSec VPN. This ActiveX component once downloaded will be running paralleled with the “Login Success Page” after the page being brought up s...
Edimax AC-M3000/AC-M1000 User’s Manual 132 Suggestion: Please TURN OFF Internet Connection Firewall feature or upgrade the Windows OS into Windows XP SP2. 4. ICMP and Active Mode FTP On Windows XP SP2 without patching by KB889527, it will drop ICMP packets from IPSec tunnel. This problem can be fixe...
Edimax AC-M3000/AC-M1000 User’s Manual 133 Reasons may cause the Internet Explorer to stop the ActiveX unexpectedly as followings: a. The crash of Internet Explorer on running ActiveX Suggestion: Please reboot client’s computer, once Windows service is resumed, go through the login process again. b....
Edimax AC-M3000/AC-M1000 User’s Manual 134 c. There are some cases of Windows messages by which Edimax AC-M3000 will hint current user to: (1) Close the Windows Internet Explorer, (2) Click “logout” button on “login success” page, (3) Click “back” or “refresh” of the same Internet Explorer, (4) Ente...
Edimax AC-M3000/AC-M1000 User’s Manual 135 8. Appendix D –Proxy Setting for Hotspot HotSpot is a place such as a coffee shop, hotel, or a public area where provides Wi-Fi service for mobile and temporary users. HotSpot is usually implemented without complicated network architecture and using some pr...
Edimax AC-M3000/AC-M1000 User’s Manual 136 3. Click the Proxy Server Properties from left menu and the homepage of the Proxy Server Properties will appear.
Edimax AC-M3000/AC-M1000 User’s Manual 137 4. Add the ISP’s proxy Server IP and Port into External Proxy Server Setting.
Edimax AC-M3000/AC-M1000 User’s Manual 140 9. Appendix E –Proxy Setting for Enterprise Enterprises usually isolate their intranet and internet by using more elaborated network architecture. Many enterprises have their own proxy server which is usually at intranet or DMZ under the firewall protection...
Edimax AC-M3000/AC-M1000 User’s Manual 142 4. Add your proxy Server IP and Port into External Proxy Server Setting. 5. Disable Built-in Proxy Server in Internal Proxy Server Setting.
Edimax AC-M3000/AC-M1000 User’s Manual 143 6. Click Apply to save the settings . Warning : If your proxy server is disabled, it will make the user authentication operation abnormal. When users open the browser, the login page won’t appear because the proxy server is down. Please make sure your proxy...
Edimax AC-M3000/AC-M1000 User’s Manual 144 2. Open browser to add default gateway IP address (e.g. 192.168.1.254) and logout page IP address “1.1.1.1” into proxy exception information. z For I.E z For firefox
Edimax AC-M3000/AC-M1000 User’s Manual 146 10. Appendix F –Disclaimer for On-Demand Users In Edimax AC-M3000, the end user first gets a login page when she/he opens its web browser right after associating with an access point. However, in some situations, the hotspot owners or MIS staff may want to ...
Edimax AC-M3000/AC-M1000 User’s Manual 147 return unescape(pham.substring(offset, endstr)); // return cookie value section } i = pham.indexOf(" ", i) + 1; // move i to next name=value pair if (i == 0) break; // no more values in cookie string } return null; // cookie not found } function Cod...
Edimax AC-M3000/AC-M1000 User’s Manual 148 var i,j=d.MM_p.length,a=MM_preloadImages.arguments; for(i=0; i<a.length; i++) if (a[i].indexOf("#")!=0){ d.MM_p[j]=new Image; d.MM_p[j++].src=a[i];}} } function MM_findObj(n, d) { //v4.01 var p,i,x; if(!d) d=document; if((p=n.indexOf("?")...
Edimax AC-M3000/AC-M1000 User’s Manual 149 if(form.mypassword.value == "") { alert("Please enter password."); form.mypassword.focus(); form.mypassword.select(); disableButton=false; return false; } if(disableButton==true) { alert("The system is now logging you in, please wait a m...
Edimax AC-M3000/AC-M1000 User’s Manual 151 illegal activities; customize, measure, and improve our services and the site's content and layout; compare information for accuracy, and verify it with third parties. We may disclose personal information to respond to legal requirements, enforce our polici...
Edimax AC-M3000/AC-M1000 User’s Manual 155 11. Appendix G—DHCP Relay AC-M3000 supports DHCP Relay defined according to RFC 3046 . For scaling reasons, it is advantageous to set up an external DHCP server other than having the internal DHCP server implemented in AC-M3000 to assign an IP. When forward...
Edimax AC-M3000/AC-M1000 User’s Manual 156 Here is an example of configuration file of the DHCP server: From the file, client that connects to AC-M3000 sends out a DHCP request. DHCP relay function in AC-M3000 is enabled and sending a Circuit ID 00:90:0B:07:60:91_192.168.1.254 to the external DHCP s...
Edimax Manuals
-
Edimax EW-7711UMN
Manual
-
Edimax PS-1206U
Manual
-
Edimax LAN USB Adapter
Manual
-
Edimax EW-7708Pn
Manual
-
Edimax EW-7748In
Manual
-
Edimax EW-7128g
Manual
-
Edimax PS-1208UWg
Manual
-
Edimax EU-4207
Manual
-
Edimax EW-7727In
Manual
-
Edimax PS-1206PWg
Manual
-
Edimax PS-3103P
Manual
-
Edimax EW-7717Un
Manual
-
Edimax 802.11 b
Manual
-
Edimax EU-4230
Manual
-
Edimax PT-111E
Manual
-
Edimax EN-9130TXA
Manual
-
Edimax IC-7000
Manual
-
Edimax EW-7205AP
Manual
-
Edimax Draft 2.0-N
Manual
-
Edimax PT-31W
Manual