Page 2 - Table of contents
Table of contents Table of contents 1 Thank you 2 Energy saving tips 2 Notes 2 Specifications 3 Safety precautions 3 Parts 5 Front view 5 Rear view 5 Accessories 6 Installation 7 Installing the exhaust hose 7 Window installation 8 Wall installation 9 Notes 10 Control panel 11 LED indicators 11 Butto...
Page 3 - Thank you; Avoid opening doors frequently
Thank you Thank you for purchasing an EdgeStar portable air conditioner. Rest assured that all EdgeStar products are designed and manufactured to the highest standards. We would like you to be able to fully utilize all features of this portable air conditioner, so please take the time to read this o...
Page 4 - Always place the unit on a level surface.
Specifications Model AP410W Maximum Room Size (cooling)* 400 ft² Power consumption for cooling mode 1000W Air flow 212 ft³/m Humidity removal capacity 2.11 p/h Noise level <54 dbA Power supply 115V/ 60Hz Compressor Rotary Refrigerant R-22 Refrigerant Load 15.2 oz Timer 1-12 hours Thermostat 61°-8...
Page 6 - Parts; Front view
Parts Front view 1. Control panel 2. Adjustable louvers 3. Carry handles 4. Caster wheels Rear view 1. Air inlet 2. Exhaust port 3. Power cord hooks 4. Caster wheels 5. Drain plug (a plastic drain cap covers a rubber stopper) 6
Page 7 - Accessories
Accessories Owner’s manual and warranty card Drain hose Exhaust hose Rectangular vent connector Round adapter Drain tray Carbon filter Cap for round adapter Plastic window kit and screws Remote and batteries 7
Page 8 - Installing the exhaust hose
Installation Installing the exhaust hose In order to be used effectively, the exhaust hose must be mounted to the back of the unit. 1. Make sure the rectangular vent connector is fitted to one end of the exhaust hose and fit the round adapter to the other end. 2. Insert the rectangular vent connecto...
Page 12 - Control panel; LED indicators
Control panel LED indicators 1. “ST” = Set Temperature When this light is lit (when the TEMP. UP or TEMP. DOWN buttons are pressed), the LED display shows the temperature that the unit is set to cool to. 2. “RT” = Room Temperature When this light is lit the LED display shows the current ambient temp...
Page 13 - Remote Control; Setting up the remote control
If this light is flashing, the internal condensate tank is full and the unit has shut itself off. Empty the tank to restart the unit. See the Drainage section for more information on performing this operation. Buttons 1. “TEMP. UP” = Adjusts Temperature Up This button raises the thermostat temperatu...
Page 14 - Remote control functions; “On Timer” button
Caution: Do not abuse the remote control. Do not expose the remote control to direct sunlight or leave it next to a radiator or another source of heat. Do not mix different types of batteries in the remote control. Remote control functions 1. LCD Display This displays the time and the settings selec...
Page 15 - Press and hold the On timer and Off timer buttons
This button activates or deactivates the “On timer.” As noted in more detail above, the On timer turns the portable air conditioner on after a number of hours (you select the number of hours) elapses. To set the On timer using the remote control, the portable air conditioner must be off. Press the O...
Page 16 - Regulating airflow direction
Regulating airflow direction To adjust airflow, the louvers on this portable air conditioner can be adjusted up and down and from right to left. To adjust the horizontal louvers, gently move them up or down as desired. To adjust the vertical louvers, move the handle at the bottom of the louvers. 16
Page 17 - Manual drainage; Draining with the drain tray
Manual drainage When the portable air conditioner is in cooling or dry mode, it will dehumidify the air. The water dehumidified from the air will be collected in an internal reservoir. This water will be used to help cool the compressor and it will be evaporated and exhausted out the exhaust hose. T...
Page 18 - Empty the drain tray.; Direct drainage; Remove the drain cap and rubber plug from the drain.; Maintenance; Cleaning the exterior; Use a soft damp cloth to wipe the body clean; Prefilter and charcoal filter
5. Empty the drain tray. 6. Repeat steps 1-5 as necessary. Direct drainage 1. Remove the drain cap and rubber plug from the drain. 2. Connect the drain hose to the drain. The drain hose can be extended if needed. The portable air conditioner will now drain through the drain hose. Please note that th...
Page 19 - Long term storage
Installing the charcoal filter 1. Grasp the filter frame (it slides in and out of the top back of the portable air conditioner) and pull up until it slides completely out of the unit. 2. Lay the filter frame on a flat surface, and remove the plastic grid from the filter frame. 3. Lay the charcoal fi...
Page 20 - Troubleshooting; Problem
Troubleshooting If the portable air conditioner is not working properly, it is usually due to a minor problem that the user can handle. Before calling customer service, refer to the following chart for troubleshooting: Problem Possible Causes Solutions The plug is not properly installed into a power...
Page 23 - day from the date of
Limited warranty: This EdgeStar product is warranted to be free from defective workmanship and materials for the first year following the date of original purchase. Replacement parts will be supplied free of charge for the first year following the date of original purchase. Labor will be performed f...