EdgeStar AP550Z - Manual
EdgeStar AP550Z – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Troubleshooting and reconnecting wires to the “compressor capacitor” on the
AP550Z
Tools required:
Phillips screwdriver
The problem:
If the AP550Z was recently shipped or roughly moved, it may have one of two problems:
•
The fan to the interior of the room turns on, but the air blown out of it is room
temperature. Or,
•
The unit blows the circuit breaker it is run on
Warnings:
•
Make sure the unit is disconnected from the power supply prior to working
on it
•
Do not attempt this repair if you do not feel comfortable with any procedures
•
If you require any assistance, please call EdgeStar Service at 866-319-5473
The repair:
1.
Make sure the unit is unplugged
2.
Face the rear of the unit
3.
Remove the filter frame:
it
it
Pull up on the
filter frame, then
pull down and
away from the un
to remove
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.