Page 2 - PXES4P Switches; PXES4P Series Switches; Trademarks; The PXES4P, 10/100 Mb/s Convenient Switches contain no user
PXES4P Switches Installation and User Guide (10/06) 1 PXES4P Series Switches Installation and User Guide Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a registered trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Important: The PXES4P, 1...
Page 3 - Federal Communications Commission; measures may be required to correct the interference.
PXES4P Switches Installation and User Guide (10/06) 2 Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, ma...
Page 4 - Contacting EATON; EATON ELECTRICAL, INC; For Technical Support please call
PXES4P Switches Installation and User Guide (10/06) 3 Contacting EATON EATON ELECTRICAL, INC For Technical Support please call 800-809-2772 Or 414-449-7100 Or visit our Website http://www.eatonelectrical.com
Page 5 - TABLE OF CONTENTS; Power Requirements, Power Supply Types for PXES4P Series
PXES4P Switches Installation and User Guide (10/06) 4 TABLE OF CONTENTS Page 1.0 SPECIFICATIONS ............................................................................... 7 1.1 Technical Specifications ..................................................................... 7 2.0 INTRODUCTION .......
Page 6 - Troubleshooting
PXES4P Switches Installation and User Guide (10/06) 5 3.6 Powering the PXES4PH with 12V, 24V or –48VDC power input... 31 3.7 PXES4P, DC-powered, -48VDC, 24VDC and 12VDC Installation. 33 3.8 Connecting Twisted Pair (RJ-45 ports).............................................. 35 3.8.1 Connecting Twiste...
Page 8 - Technical Specifications; Ports Performance; When a port is operating at 100Mbps:; Network Standards
PXES4P Switches Installation and User Guide (10/06) 7 1.0 SPECIFICATIONS 1.1 Technical Specifications Ports Performance When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, IEEE 802....
Page 9 - Packet-Processing Between Domains; Filter / Forwarding Rate from 100Mbps ports: 148,800 pps max; Path Delay Value; Ambient Temperature : -13
PXES4P Switches Installation and User Guide (10/06) 8 Packet-Processing Between Domains Filter / Forwarding Rate from 100Mbps ports: 148,800 pps max Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max. Processing type: Store and Forward, non-blocking Auto-learning: 2K address table Addr...
Page 10 - Storage Temperature: -40; Weight
PXES4P Switches Installation and User Guide (10/06) 9 Long term per independent agency tests (UL): -40 º F to 167 º F (-40 º C to 75 º C) Storage Temperature: -40 º F to 185 º F (-40 º C to 85 º C) Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude : -200 to 5000ft. (-60 – 15,000 m) Conf...
Page 11 - The case is used as a heat sink on this model.; Hi”; models that have IEC320 power connector built-in the PS unit.
PXES4P Switches Installation and User Guide (10/06) 10 Cooling Method: The case is used as a heat sink on this model. POWER SUPPLY : These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked “Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rat...
Page 12 - for; Power Consumption; -15V DC can be used for dual source DC input
PXES4P Switches Installation and User Guide (10/06) Input: 100-240V AC at 47-63Hz, for “-Pd” high temp. 100-240V AC at 47-63Hz, “-Pi” models that have IEC320 power connector built-in the PS unit. Out put- 12vdc, 2 Amps DC to unit : 12V DC, 2.5mm jack, center +ve, 6ft. cord Power Supply ( Direct DC )...
Page 13 - LK/ACT: Steady ON for LINK with no traffic, blinking indicates port; Mounting option for PXES4P Family of Switches:
PXES4P Switches Installation and User Guide (10/06) 12 Note 2: Internal DC power floats, user may ground “+” or “-” if desired. Port Connectors: RJ-45 Port: Auto-cross(MDIX), 100BASE-TX and 10BASE-T:shielded 8-pin female. Three RJ-45 ports provided in front, and one on the rear. Supports shielded (S...
Page 14 - Metal Mounting clips for panel mounting; NEBS L3 and ETSI compliant
PXES4P Switches Installation and User Guide (10/06) 13 Metal Mounting clips for panel mounting : included DIN-Rail mounting option : Model :#PXESDINRL Rack-mount option : #PXESTRAY Mean Tine Between Failure (MTBF ) – 15+ years, Telcordia (Bellcore SR-332) Method Agency Approvals and Standard Complia...
Page 15 - Summary of model and descriptions:; Ext. AC Hardened power supply included .; PXESDINRL = Metal DIN-Rail mounting bracket for one PXES4P Series; typical applications.; Inspecting the Package and the Product
PXES4P Switches Installation and User Guide (10/06) Examine the shipping container for obvious damage prior to installing this product; notify the carrier immediately of any damage which you believe occurred during 14 1.2 Summary of model and descriptions: PXES4P-Hd, Hi = Hardened, four 10/100 RJ-45...
Page 16 - This package should contain:
PXES4P Switches Installation and User Guide (10/06) 15 shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included. This package should contain: 1 PXES4P Series Switch Unit 1 External Power Supply (d, i model only) 1 set Meta...
Page 17 - Product Description
PXES4P Switches Installation and User Guide (10/06) 16 Remove the PXES4P Series Switch from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. In the event there are items missing or damaged contact your supplier. If you need to return th...
Page 18 - and use special thermal techniques and a rugged metal case for
PXES4P Switches Installation and User Guide (10/06) The PXES4P as shown above in Fig 2.2c is a hardened unit designed for factory floor and other industrial applications. The PXES4P models are built with high-grade components and use special thermal techniques and a rugged metal case for extended te...
Page 19 - Eaton PX; PXES4P left side view; Side View
PXES4P Switches Installation and User Guide (10/06) Fig 2.2c- PXES4P, right side view (three RJ-45 ports on Front side of the unit, as shown 18 10/100 F/H PW R LA3 LA1 LA2 A 1 2 3 Eaton PX Right Fig2.2c. PXES4P, left view (one RJ-45 port and DC option on left side) as shown in Fig. c 8 – 15V DC + - ...
Page 21 - Frame Buffering and Latency; the available bandwidth to be used for valid information.
PXES4P Switches Installation and User Guide (10/06) 20 2.4 Frame Buffering and Latency The PXES4P Series Switches are store-and-forward switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding can occur. This technique ensures that all forwarded frames are ...
Page 24 - Two sets of LEDs for viewing status from any angle
PXES4P Switches Installation and User Guide (10/06) 23 The PXES4P Series Switches operate as LAN switches only forwarding those packets from each domain that are needed on the other domains. Internal address tables are self-learning. All ports are auto-cross. Two sets of LEDs for viewing status fr...
Page 25 - Efficient Compact design, for all-purpose convenient mounting
PXES4P Switches Installation and User Guide (10/06) 24 The 12V DC jack is present on DC-input models, so that the unit can operate from an external AC PS, or from DC applied to the terminal block, either or both present. Dual-source power may increase availability, or be convenient to move the unit ...
Page 26 - port #1 with twisted pair cabling to add 3 more ports.
PXES4P Switches Installation and User Guide (10/06) compact PXES4P Series 10/100 Mbps switch functions support a mixed environment of 10 Mbps and 100Mbps users. The switching full / half duplex capability on all four ports provide bandwidth for high performance. Port #1 (on the back end) is typicall...
Page 27 - Locating the Convenient Switch Unit
PXES4P Switches Installation and User Guide (10/06) 26 Example : In this application in an expanding Industrial network environment, the new PLC units are deployed on all the present networks and need an Ethernet port to carry the data to the main workstation being controlled by the Industrial Engin...
Page 28 - Secure attachment of mounting; Installation of the PXES4P Series Switches
PXES4P Switches Installation and User Guide (10/06) economical tool to expand the existing network. The compact and lightweight design of the S-Series allows it to be easily installed in almost any location. Metal mounting clips and screws are included for a rugged and secure mounting in any orienta...
Page 29 - PXESTRAY for Rack Mounting of PXES4P Series Switches
PXES4P Switches Installation and User Guide (10/06) 3.2 PXESTRAY for Rack Mounting of PXES4P Series Switches For 19” rack mounting of PXES4P Series Switches, a rack-mount tray is available, the part number is PXESTRAY. The Convenient Switches along with Media Converter units are mounted with their R...
Page 30 - The PXES4P Models with “HR” have 24VDC power, and have the PXESDINRL
PXES4P Switches Installation and User Guide (10/06) 29 three to eight) PXES4P Series Switches, with their power supplies plugged into power strips (not included) in the rear area of the tray. Metal mounting screws in the bottom-front hold the Media Converters firmly in place. The beveled-top edge of...
Page 31 - is being provided in Technical Specifications Section 1.1.
PXES4P Switches Installation and User Guide (10/06) 30 3.5 Power Requirements, Power Supply Types for PXES4P Series Switches PXES4P Series Switches are power-efficient and can work with an external AC power supply. PXES4P Series require a nominal 12VDC input (range 8 to 15V, see Specifications) at t...
Page 32 - in uncontrolled temperature environments.
PXES4P Switches Installation and User Guide (10/06) The PXES4P Series are designed to provide reliable operation, withstand higher temperature environments, and provide the Direct DC power choices to the user to deploy in uncontrolled temperature environments. 12VDC 24VDC -48VDC The Internal 12V DC ...
Page 33 - in screw terminals for secure attachment of the power; DC Power Terminals
PXES4P Switches Installation and User Guide (10/06) The PXES4P is reliably equipped with a Direct DC power supply, and have built- in screw terminals for secure attachment of the power leads. Three models support a range of power input types. The three model choices are for use with 12VDC, 24VDC or ...
Page 35 - will connect to the post labeled “+ve” and the rest to the “-ve”.
PXES4P Switches Installation and User Guide (10/06) 34 The connection procedure is straightforward. Simply insert the DC leads to the PXES4PH’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it connects to the PXES4PH chassis. Ensure that each lead is sec...
Page 36 - Media; 00BASE-TX RJ-45
PXES4P Switches Installation and User Guide (10/06) 35 3.8 Connecting Twisted Pair (RJ-45 ports) The PXES4P Series Switches can be connected to only one media type with two different speed i.e. 100BASE-TX and 10BASE-T. CAT 5 cables should be used when making 100BASE-TX connections. When the ports ar...
Page 37 - shielded twisted pair cables.
PXES4P Switches Installation and User Guide (10/06) 36 3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded) The following procedure describes how to connect a 10BASE-T or 100BASE-TX twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and shi...
Page 38 - Connections to NICs which support Auto-Negotiation, RJ-45 ports
PXES4P Switches Installation and User Guide (10/06) 37 3.8.2 Connections to NICs which support Auto-Negotiation, RJ-45 ports The copper ports of PXES4P Series Switches will function properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse (FLP) coding for ...
Page 39 - The PXES4P Series Switches provide
PXES4P Switches Installation and User Guide (10/06) 38 4.0 OPERATION 4.1 Dual-Speed Functionality, and Switching The PXES4P Series Switches provide four switched ports (three ports in the front and one on the rear). The architecture supports a dual speed switching environment, with auto-negotiation ...
Page 40 - Switching, Filtering and Forwarding; which eliminates bad packets and enables peak performance.
PXES4P Switches Installation and User Guide (10/06) 39 Switching, Filtering and Forwarding Each time a packet arrives on one of the switched ports, the decision is taken to either filter or to forward the packet. Packets whose source and destination addresses on the same port segment will be filtere...
Page 41 - Switching, Address Learning
PXES4P Switches Installation and User Guide (10/06) 40 Switching, Address Learning The PXES4P Series units have address table capacity of 2K node addresses, and are suitable for use in large networks. They are self-learning, so that as nodes are added or changed, the PXES4P Series automatically keep...
Page 42 - When an RJ-45 cable connection is made, and each time LINK is enabled,; LED Description; Illuminates GREEN to indicate power applied.
PXES4P Switches Installation and User Guide (10/06) 41 cases, the 10/100 speed or the F/H mode may be affected, but auto-cross in the PXES4P Switches will still work. The auto-cross function cannot be disabled. When an RJ-45 cable connection is made, and each time LINK is enabled, auto-negotiation t...
Page 44 - is also straightforward and is discussed in Section 4.
PXES4P Switches Installation and User Guide (10/06) 43 5.0 TROUBLESHOOTING All Ethernet products are designed to provide reliability and consistently high performance in all network environments. The installation of PXES4P Series 10/100 Mb/s Switches is a straightforward procedure (see INSTALLATION,...
Page 45 - Before Calling for Assistance
PXES4P Switches Installation and User Guide (10/06) 44 5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the applicable chapter of this manual. Also check to make sure that the various components of the ...
Page 46 - When Calling for Assistance; Please be prepared to provide the following information.
PXES4P Switches Installation and User Guide (10/06) 45 5. If the problem continues after completing Step 4 above, contact your supplier of the PXES4P Series 10/100 Mb/s Switch unit or if unknown, contact EATON, Inc 5.2 When Calling for Assistance Please be prepared to provide the following informati...
Page 48 - Shipping and Packaging Information
PXES4P Switches Installation and User Guide (10/06) 47 EATON will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix ...
Page 49 - outside of the shipping container.; EATON; Cherrington Parkway
PXES4P Switches Installation and User Guide (10/06) 48 CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static shock damage to the unit. 2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping co...
Page 50 - Appendix A: WARRANTY INFORMATION
PXES4P Switches Installation and User Guide (10/06) 49 Appendix A: WARRANTY INFORMATION This product offered by Eaton Corporation, is warranted against defects in material and workmanship for a period of three years from the date of shipment, under normal use and service. During the warranty period,...
Page 51 - Repair After Warranty Expiration
PXES4P Switches Installation and User Guide (10/06) 50 NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. EATON CORPORATION SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A APRTICULAR PURPOSE. Warranty Repair If you believe your equipment is in need of repair, call Eaton Co...