Page 2 - TABLE OF CONTENTS
2 SECTION I—GENERAL Introduction ................................................................................................................................................................. 3 I-A Importance of Instructions ...........................................................................
Page 3 - Introduction; SECTION I — GENER AL; SECTION II — INSTALLATION
3 Introduction This instruction manual is intended to assist those involved with the installation, operation and maintenance of Eagle Model A100 pumps. It is recommended that this manual be thoroughly reviewed prior to installing or performing any work on the pump or motor. I-A. Importance of Instru...
Page 4 - Baseplate Initial Alignment Check
4 II-C. Leveling and Grouting of Baseplate Initial Alignment Check 1. Put the unit in place on wedges located at four points as shown in Fig. 2. Some long installations may require additional wedges near center of bedplate. 2. Adjust wedges to level unit (approximately), placing unit between 3⁄4” an...
Page 5 - SECTION III—OPERATION
5 PRIOR TO COUPLING DRIVER TO PUMP, ROTATION OF DRIVER SHOULD BE CHECKED! Serious damage can result if pump is rotated in wrong direction. Once motor rotation is checked, connect coupling, following the manufacturer’s instructions. If a coupling guard is furnished with the unit, ensure that it is se...
Page 6 - SECTION IV—PREVENTIVE AND CORRECTIVE MAINTENANCE
6 b. A high quality turbine type oil with rust and oxidation inhibitors should be used. Under normal operating conditions, an oil of 300 SSU viscosity at 100° F. (approximately SAE 20) should be used. Fill oiler bottle and replace in oiler housing. Repeat until oil remains visible in bottle. Do not ...
Page 7 - SECTION V—DISASSEMBLY AND REASSEMBLY; Replacement Guidelines
7 SECTION V—DISASSEMBLY AND REASSEMBLY V-A. Disassembly (refer to Sectional Views in Part VI) 1. Prepare pump for disassembly as follows: a. Lock out power supply to motor. b. Shut off valves controlling flow to and from pump. c. Flush pump of all corrosive or toxic liquid, if required. d. Remove al...
Page 9 - SECTION VI—PRODUCT DESCRIPTION
9 13. Place casing gasket (351) against shoulder in casing. 14. Slide the pullout assembly into the casing (100). Drain slot in stuffing box cover (184) should line up with drain connection in casing. Install frame–to–casing bolts (370) and tighten evenly while rotating shaft (122) by hand. If impel...
Page 10 - Recommended Spare Parts; Parts List and Materials of Construction
10 101106 112A 126 168A 261 332A333A 351 360C360D412A469D 496 1 1 set 111111111111 ImpellerStuffing Box Packing (2) Ball Bearing-Outboard.Shaft SleeveBall Bearing-InboardMechanical Seal Gland Gasket (3) Oil Seal-OutboardOil Seal-InboardGasket-CasingGasket-Bearing End Cover-Bearing HousingGasket-Bear...
Page 11 - Assembly View of 8” Pumps Only
11 Model A100 S, M, L Assembly View of 8” Pumps Only 100 239 105 106 412A 469D 101 351 122A 355 353 107 333A 370D 113A 496 361A 168A 123 210 261 126 370H 184 370 228A 112A 134A 332A 136 & 382 370C 370503
Page 12 - l A
12 M o d e l A 10 0 M , L 132 370 184 168A 360D 496 108 107 355 353 123 113A 228A 370C 134A 136 & 382 332A 112A 370D 361A 370E 370H 126 122A 210 333A 106 370F 131 239 105 469D 412A 106 101 351 100
Page 14 - SECTION VII—TROUBLE SHOOTING; Problem
14 Causes & Corrective Measures 1. Pump not primed or properly vented—check that casing and suction pipe are completely filled with liquid. 2. Speed too low—check whether motor wiring is correct and receives full voltage or turbine receives full steam pressure. 3. System discharge head too high—...
Page 15 - SECTION VIII—ORDERING SPARE PARTS; Parts
15 SECTION VIII—ORDERING SPARE PARTS VIII-B. Instructions for Ordering Spare Parts Repair orders will be handled with the minimum of delay if the following directions are followed: 1. Give model number, size of pump, and serial number. These can be obtained from the nameplate on the pump. 2. Write p...
Page 16 - EAGLE; ANSI Centrifugal Pumps
EAGLE EAGLE PUMP & COMPRESSOR LTD. 7025 - 5 Street S.E., Calgary, AB T2H 2G2 Canada ANSI Centrifugal Pumps Multistage Horizontal Pumps Vertical Sump Pumps Rotary Screw Compressor Air/Gas Dryers www.eagle-pc.com Printed in Canada 01/2000