Page 2 - TABLE OF CONTENTS
EXCEL-FIRE GAS STOVE 1 TABLE OF CONTENTS GENERAL INFORMATION ......................................................................................................................... 2 WARNING ..............................................................................................................
Page 3 - GENERAL INFORMATION; SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE; WARNING
EXCEL-FIRE GAS STOVE 2 GENERAL INFORMATION The EXCEL-FIRE gas stove is a high-efficiency free-standing gas appliance with a maximum input rating of 30 000 BTU/h (8,8 kW) with natural gas or 26 000 BTU/h (7,6 kW) with propane. It features an adjustable millivolt valve and a constant pilot. This means...
Page 4 - TECHNICAL SPECIFICATIONS
EXCEL-FIRE GAS STOVE 3 TECHNICAL SPECIFICATIONS Dimensions • Height : 29 ¾ in. 756 mm • Width : 24 in. 610 mm • Depth : 20 in. 508 mm Glass 18 ½ in. x 10 ½ in. 470 mm x 267 mm Weight 140 lbs 64 kg Colour metallic black Flue pipe "B-Vent" ou "L-Vent" ∅ 4 in. (100 mm) Clearance to comb...
Page 5 - Burner; Pressure Adjustments
EXCEL-FIRE GAS STOVE 4 Burner Naturel Gas Propane LP Maximum Input, BTU/h (kW) minimum : maximum : 20 000 (5,9) 30 000 (8,8) 20 000 (5,9) 26 000 (7,6) Inlet Pressure INWC (kPa) minimum : maximum : 5,0 (1,3) 7,0 (1,8) 11,0 (2,8) 14,0 (3,5) Manifold Pressure INWC (kPa) minimum : maximum : 1,8 (0,5) 3,...
Page 6 - INSTALLATION; Safety notice
EXCEL-FIRE GAS STOVE 5 INSTALLATION Safety notice • Improper installation may result in a house fire. Follow installation directions. Installation must be in accordance with local building codes or, in the absence of local codes, with current CAN/CGA B 149 installation codes for gas appliances in Ca...
Page 7 - Logs installation
EXCEL-FIRE GAS STOVE 6 For clearance between pipe and flammable materials, follow vent pipe manufacturer’s instructions . Logs installation
Page 8 - Rock wool fiber installation; Optional 6-inch pipe installation; OPERATION INSTRUCTIONS; Wall thermostat
EXCEL-FIRE GAS STOVE 7 1. Remove the two door retaining screws at the bottom right and left of the door. 2. Remove the door. 3. Locate the log grate in the retainers in the right and left rear corners. 4. Place the rear log (1) against the rear log stop. Make sure grooves at the back of the log line...
Page 9 - Optional blower; Blower electrical connection
EXCEL-FIRE GAS STOVE 8 DISTANCE DIAMETRE 20 pi 18GA 30 pi 16GA 40 pi 14 GA 50pi 12GA REMOVE THE BLUE JUMPER BETWEEN TP & TPTH SCREWS ON THE GAS VALVE. Optional blower The blower control contains a variable speed switch and a thermal switch. When the stove is operating, the thermal switch will tu...
Page 10 - Gas connection; Spill switch; LIGHTING PROCEDURES; Before lighting; The first fire
EXCEL-FIRE GAS STOVE 9 Gas connection • Move the EXCEL-FIRE to the desired position and secure in place with four screws. • Connect gas line to the stove using listed connectors • Check the gas line piping for leaks. Use a soap and water solution. WARNING : DO NOT USE OPEN FLAME TO CHECK LEAKS. Spil...
Page 11 - Shutdown procedures; MAINTENANCE INSTRUCTIONS; Glass maintenance
EXCEL-FIRE GAS STOVE 10 1. Open the pedestal front panel to reach the control. 2. Make sure the gas control knob is turned to the ‘’OFF’’ position. If it is not, press knob slightly and turn clockwise 3 to the "OFF’’ position. Do not force the gas control knob. If the gas control was in the on p...
Page 12 - Glass door; Burner removal and installation; Removal
EXCEL-FIRE GAS STOVE 11 If Your Glass Breaks: • See your dealer for exact replacement glass. • Remove front as explained above. With a 5/16” nut driver remove all nuts holding the glass retainers. Carefully remove retainers and seal. • After removing all broken glass pieces, insert new glass and rei...
Page 13 - Installation; Gas pressure adjustments
EXCEL-FIRE GAS STOVE 12 Installation • Put the burner assembly back in the fire box and push to the right. • Make sure the main orifice is inserted in the ventury tube as shown. And screw the burner back into place. WARNING: Never operate the gas stove without having the orifice properly inserted in...
Page 14 - Pilot assembly; OPTIONS; REPLACEMENT PARTS
EXCEL-FIRE GAS STOVE 13 Pilot assembly Adjusting air shutter (Venturi) The factory setting for the air shutter is 1/4” for natural gas, fuily open for propane. After operating the appliance for half an hour or so the flames should have turned a nice yellow colour. However, in higher altitudes you ma...
Page 15 - LIMITED WARRANTY
EXCEL-FIRE GAS STOVE 14 1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e-mail : [email protected] web site : drolet .ca LIMITED WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty cov...