Page 2 - TABLE OF CONTENTS
ULTRA FLAME DIRECT VENT GAS STOVE 1 TABLE OF CONTENTS GENERAL INFORMATION .................................................................................................................................................... 2 WARNING ......................................................................
Page 3 - GENERAL INFORMATION; KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE; WARNING; Installation should be done by a qualified installer.
ULTRA FLAME DIRECT VENT GAS STOVE 2 GENERAL INFORMATION The ULTRA FLAME DIRECT VENT GAS STOVE is a high-efficiency gas appliance with a maximum input rating of 30 000 Btu/h (8,8 kW) with natural gas or 26,000 Btu/h (7,6 kW) with propane. It features an adjustable millivolt valve and a constant pilot...
Page 4 - TECHNICAL SPÉCIFICATIONS; Dimensions
ULTRA FLAME DIRECT VENT GAS STOVE 3 TECHNICAL SPÉCIFICATIONS Dimensions TOP VIEW Dimensions Height : 29 in 735 mm Width : 26 in 920 mm Depth : 23 in 585 mm Ceramic Glass F ront : 18 3/16 in x 15 15/16 in 462 mm x 405 mm Sides : 5 1/16 in x 15 15/16 in 129 mm x 405 mm Weight : 140 lbs 64 kg Color : M...
Page 5 - Pressure Adjustments
ULTRA FLAME DIRECT VENT GAS STOVE 4 Burner Natural Gas Propane LP Maximum Input, BTU/h (kW) minimum : maximum : 20 000 (5,9) 30 000 (8,8) 20 000 (5,9) 26 000 (7,6) Inlet Pressure INWC (kPa) minimum : maximum : 5,0 (1,3) 7,0 (1,8) 11,0 (2,8) 14,0 (3,5) Manifold Pressure INWC (kPa) minimum : maximum :...
Page 6 - Available Wall Venting Kits
ULTRA FLAME DIRECT VENT GAS STOVE 5 Available Wall Venting Kits Venting Kit for Direct Installation AC05506 Venting Kit for Corner Installation AC05507 DESCRIPTION • Outer pipe ( ∅ 8 in.) for admission of fuel-air in carbon steel, black 24GA ; • Inner flexible pipe ( ∅ 5 in.) in aluminum allowing th...
Page 7 - SELECTING TYPICAL INSTALLATION; Safety Notice; Positioning the Stove
ULTRA FLAME DIRECT VENT GAS STOVE 6 SELECTING TYPICAL INSTALLATION Safety Notice • Improper installation may result in a house fire. Follow installation directions. Installation must be done in accordance with local building codes or, in the absence of local codes, with current CAN/CGA B 149 install...
Page 9 - INSTALLATION OF YOUR STOVE; Pedestal cover
ULTRA FLAME DIRECT VENT GAS STOVE 8 K. 72" Clearance to a mechanical air supply inlet L. 84" Clearance above paved sidewalk or a paved driveway located on public property. A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwelli...
Page 10 - Installation of Wall Venting Kits; Direct Vent Kit
ULTRA FLAME DIRECT VENT GAS STOVE 9 Installation of Wall Venting Kits Direct Vent Kit VENT TERMINAL RADIATION SHIELD -min 1" -max 60" Direct Vent Direct Vent Details 1. Move the stove to its position; 2. Install temporary a 8 in. section (4) to visualize where the opening to be done thru the...
Page 11 - Direct Vent Kit for Corner Installation
ULTRA FLAME DIRECT VENT GAS STOVE 10 13. Seal around the 8 in. pipe to prevent cold air to get into the house. 14. Seal around the cover slots to avoid water infiltration into the vent terminal; 15. Insert spring spacers into the 5 in. flexible pipe; 16. Put some high temp silicone on the stove’s 5 ...
Page 13 - Direct Vent Kit for Basement Installation
ULTRA FLAME DIRECT VENT GAS STOVE 12 Direct Vent Kit for Basement Installation 1. Move the stove to its position; 2. Install temporary an 8 in. section (4) to visualize where the opening to be done thru the wall. Center of the opening should be at about 23 ½ “above the base of the stove; Note: Horiz...
Page 15 - Direct Vent Kit for Floor Installation
ULTRA FLAME DIRECT VENT GAS STOVE 14 Direct Vent Kit for Floor Installation 1. Move the stove to its position; 2. Install temporarily an 8 in. section (4) to visualize where the opening is to be done thru the wall. Center of the opening should be at about 23 ½‘’ above the base of the stove; Note: Ho...
Page 17 - Gas Piping; Electrical Connections
ULTRA FLAME DIRECT VENT GAS STOVE 16 Gas Piping • Move the ULTRA FLAME to the desired position. • Mark the location for the gas inlet pipe and the location where the vent pipes will go through the wall. Remove the appliance. • Route a 3/8" minimum NPT iron pipe gas line to the desired location. ...
Page 18 - Installation
ULTRA FLAME DIRECT VENT GAS STOVE 17 Logs Installation 1. Remove the front glass. 2. Locate the log grate in the retainers in the right and left rear corners. 3. Place the rear log (1) against the rear log stop. Make sure grooves under the log line up with the grate. 4. Place logs 2 and 3 against th...
Page 19 - OPERATION OF YOUR STOVE; For your safety; First Lighting
ULTRA FLAME DIRECT VENT GAS STOVE 18 OPERATION OF YOUR STOVE For your safety CAUTION: • A qualified installer must perform installation of the appliance, venting, piping and adjustments. • During operation, this stove is hot. Do not touch. Keep children, clothing and flammable materials away • Hot w...
Page 20 - Shut down Instructions; To turn the burner OFF; To turn the pilot OFF; Optional Blower
ULTRA FLAME DIRECT VENT GAS STOVE 19 Shut down Instructions To turn the burner OFF • Push in and rotate the gas control knob clockwise 3 to "PILOT" position. Do not force. To turn the pilot OFF • Push in and rotate the gas control knob clockwise 3 to "OFF" position. Do not force. Opt...
Page 21 - MAINTENANCE INSTRUCTIONS; Yearly maintenance; Bay window; Cleaning
ULTRA FLAME DIRECT VENT GAS STOVE 20 MAINTENANCE INSTRUCTIONS TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. Yearly maintenance • The venting system and the gas stove should be inspected at least once a year. • Remove the front glass and ...
Page 22 - Burner; Removing the Burner; Air Shutter Adjustment; Gas Valve SIT 820 mV; Maximum Pressure Adjustment, Altitude Installation
ULTRA FLAME DIRECT VENT GAS STOVE 21 Burner Removing the Burner • Remove the glass front assembly. Lift out the grate and hearth insert around burner. Unscrew the burner from the bottom of the combustion chamber, • Slide the burner out from the ventury towards left. Get it out from the stove. Burner...
Page 23 - Pilot Assembly; OPTIONS; REMPLACEMENT PARTS
ULTRA FLAME DIRECT VENT GAS STOVE 22 Pilot Assembly OPTIONS DESCRIPTION Part # Millivolt Wall Thermostat AC05558 Blower AC05529 Direct Vent Kit AC05506 Direct Vent Kit Corner Installation AC05507 Direct Vent Kit Basement Installation AC05509 Direct Vent Kit Floor Installation AC05502 REMPLACEMENT PA...
Page 24 - LIMITED WARRANTY
ULTRA FLAME DIRECT VENT GAS STOVE 23 1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e-mail : [email protected] web site : drolet .ca LIMITED WARRANTY The manufacturers warranty extends only to the original consumer purchaser and is not transferable. This warra...