Page 2 - TABLE OF CONTENTS
ULTRA FLAME DV “0” Clearance Fireplace TABLE OF CONTENTS GENERAL INFORMATION ................................................................................................. 3 WARNING ......................................................................................................................
Page 3 - GENERAL INFORMATION; KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
ULTRA FLAME DV “0” Clearance Fireplace GENERAL INFORMATION The ULTRA FLAME DIRECT VENT GAS FIREPLACE is a high-efficiency free-standing gas appliance with a maximum input rating of 30 000 Btu/h with natural gas or 26,000 Btu/h with propane. It features a thermostatic modulating valve and a constant ...
Page 4 - WARNING
ULTRA FLAME DV “0” Clearance Fireplace WARNING INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THIS APPLIANCE. HOT WHEN IN OPERATION. KEEP CHILDREN, FURNITURE, CLOTHING AND FLAMMABLE MATERIAL AWAY FROM THE APPLIANCE. ADVISE ADULTS AND CHILDREN ABOUT TH...
Page 5 - SPECIFICATIONS
ULTRA FLAME DV “0” Clearance Fireplace SPECIFICATIONS Dimensions: height 39", width 36", depth 20" Glass: 29-1/8" x 17-3/4" 1400oF clear ceramic Minimum opening in wall for installing the units: height: 39-1/2" width: 36-1/2" Fuel: Natural Gas Propane Input : 30,000/ 20,0...
Page 6 - OPERATION; BEFORE LIGHTING; LIGHTING PROCEDURE
ULTRA FLAME DV “0” Clearance Fireplace OPERATION BEFORE LIGHTING 1) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 2) Ma...
Page 7 - WALL THERMOSTAT
ULTRA FLAME DV “0” Clearance Fireplace • Press gas control knob in and hold. Immediately push the red igniter button repeatedly until pilot flame ignites. Continue holding in the control knob for 5 to 10 seconds, then release it. If the pilot flame goes out, repeat this step. • Push and turn gas con...
Page 8 - MAINTENANCE INSTRUCTIONS; GLASS MAINTENANCE
ULTRA FLAME DV “0” Clearance Fireplace MAINTENANCE INSTRUCTIONS TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE . The venting system and the gas fireplace should be inspected at least once a year. Remove the glass front and the logs and cle...
Page 9 - BURST DISC REPLACEMENT
ULTRA FLAME DV “0” Clearance Fireplace BURST DISC REPLACEMENT If the burst disc under the burner moves from its location, it must be put back in place into the silicone seal. Make sure the switch is depressed all the way during the installation. Otherwise the appliance will not operate. WARNING: Nev...
Page 10 - TOP, FRONT AND SIDE VIEWS
ULTRA FLAME DV “0” Clearance Fireplace TOP, FRONT AND SIDE VIEWS FRONT VIEW TOP VIEW SIDE VIEW ....................................................................................................................................................................................................... 10
Page 11 - INSTALLATION; SAFETY NOTICE; POSITIONING THE FIREPLACE
ULTRA FLAME DV “0” Clearance Fireplace INSTALLATION SAFETY NOTICE Improper installation may result in a house fire. Follow installation directions. Installation must be in accordance with local building codes or, in the absence of local codes, with current CAN/CGA B 149 installation codes for gas ap...
Page 12 - VENT TERMINAL LOCATION
ULTRA FLAME DV “0” Clearance Fireplace VENT TERMINAL LOCATION Your Ultra Flame fireplace vents through a vent terminal installed on the roof or on the outside of any exterior wall of your house. Many restrictions apply to the vent terminal location that should be considered before locating your fire...
Page 13 - MINIMUM CLEARANCE TO COMBUSTIBLES
ULTRA FLAME DV “0” Clearance Fireplace J = 12" Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance K = 72" Clearance to a mechanical air supply inlet L = 84" Clearance above paved sidewalk or a paved driveway located on public prope...
Page 14 - INSTALLATION OF THE UNIT
ULTRA FLAME DV “0” Clearance Fireplace Top of fireplace (spacer) 0" Back of fireplace 0" Sides of fireplace 0" Bottom of fireplace 0" Vent pipe: 2" Wall perpendicular to the standard surround 1/2" Mantel (from upper part of the standard surround) 6" if the projection is u...
Page 15 - DO NOT USE OPEN FLAME TO CHECK LEAKS.
ULTRA FLAME DV “0” Clearance Fireplace • Check the gas line piping for leaks. Use a soap and water solution. WARNING: DO NOT USE OPEN FLAME TO CHECK LEAKS. You are now ready to proceed to the venting kit installation. 15
Page 16 - VENTING KITS
ULTRA FLAME DV “0” Clearance Fireplace VENTING KITS STRAIGH OUT CORNER CUT TO LENGTH 10-1/2" X 10-1/2" OPENING 39-1\4" FOR CORNER INSTALLATION KIT RADIATION SHIELD 29-1\2"FOR STRAIGHT OUT "K" BASEMENT THROUGH THE WALL DETAIL 16
Page 17 - ) STRAIGHT OUT INSTALLATION; ) CORNER INSTALLATION
ULTRA FLAME DV “0” Clearance Fireplace Once the position of the fireplace and the termination cap are fixed, you should select the venting kit appropriate for your needs. First floor installations require either a STRAIGHT OUT kit or a CORNER kit while basement installations must be done with a BASE...
Page 18 - ) BASEMENT INSTALLATION
ULTRA FLAME DV “0” Clearance Fireplace • Add a spring spacer. The spring spacer must be located opposite the outside pipe joints to prevent puncturing of the inside pipe when the two sections of the outside pipe are screwed together. • Slip on the 90 ° x 8" elbow so that it faces your hole in th...
Page 19 - VENTING SYSTEM
ULTRA FLAME DV “0” Clearance Fireplace VENTING SYSTEM 19
Page 20 - VENT TERMINAL, STRAIGHT OUT AND CORNER INSTALLATION
ULTRA FLAME DV “0” Clearance Fireplace VENT TERMINAL, STRAIGHT OUT AND CORNER INSTALLATION Seal with RTV silicone between 8" diameter pipe and radiation shield inside and outside the building to prevent air passage. Install the vent terminal as shown. Insert the wall plate inside the 8" pipe...
Page 21 - VENT TERMINAL, ROOF INSTALLATION
ULTRA FLAME DV “0” Clearance Fireplace VENT TERMINAL, ROOF INSTALLATION Roof vents are required to extend at least 3 ft. above the highest point where they pass through the roof of the building and at least 2 ft. higher than any portion within 10 feet. • Clearance between combustible wall and vent p...
Page 24 - LOG INSTALLATION
ULTRA FLAME DV “0” Clearance Fireplace LOG INSTALLATION 1. Remove the glass front. 2. Locate the log grate in the retainers in the right and left rear corners. 3. Place the rear log (1) against the rear log stop. Make sure grooves under the log line up with the grate. 4. Place logs 2 and 3 against t...
Page 25 - LOUVRE INSTALLATION
ULTRA FLAME DV “0” Clearance Fireplace LOUVRE INSTALLATION The kit includes 2 louvres (black or gold) and four #8 x 1 inch machine screws and nuts. 1) Put 1 machine screw on left side of the louvre, as shown on drawing 2) Put the other screw on right side holding it tight with the nut. 3) Insert the...
Page 26 - OPTIONAL REFRACTORY PANEL INSTALLATION
ULTRA FLAME DV “0” Clearance Fireplace OPTIONAL REFRACTORY PANEL INSTALLATION 1. Remove the glass front assembly. 2. Remove the logs from the firebox. 3. Place the back refractory against the back of the firebox. 4. Install the two side refractory panels by sliding them between the firebox sides and...
Page 27 - ADJUSTMENTS
ULTRA FLAME DV “0” Clearance Fireplace ADJUSTMENTS NOTE: Adjustments to the valve assembly must be performed by a qualified service person. • The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test press...
Page 28 - ADJUSTING THE GAS PRESSURE
ULTRA FLAME DV “0” Clearance Fireplace ADJUSTING THE GAS PRESSURE NOTE: If cover plate is already installed, remove it by removing the two screws with a Phillips screw driver. NOTE: The maximum manifold pressure is set at the factory at 3.5” WC for natural gas and 10.5” WC for propane. To adjust the...
Page 29 - WALL THERMOSTAT
ULTRA FLAME DV “0” Clearance Fireplace ADJUSTING AIR SHUTTER To adjust the air shutter there is an adjustment screw. The factory setting for the air shutter is 3/16” for natural gas, ¼” for propane. After operating the appliance for half an hour or so the flames should have turned a nice yellow colo...
Page 30 - OPTIONAL PARTS; REPLACEMENT PARTS; ITEM DESCRIPTION
ULTRA FLAME DV “0” Clearance Fireplace OPTIONAL PARTS ITEM DESCRIPTION QTY 2" wide brass surround 1 5" wide brass surround 1 Brass arched door 1 200 CFM fan with thermo-switch and variable speed control 1 Decorative refractory kit 1 Surround with brass grills 1 Millivolt wall thermostat 1 RE...
Page 31 - LIMITED 5 YEAR WARRANTY
ULTRA FLAME DV “0” Clearance Fireplace LIMITED 5 YEAR WARRANTY DROLET STOVES AND FIREPLACES INC. hereby warrants the quality of its ULTRA FLAME Direct Vent Gas Fireplace against manufacturing defects. The product shall be delivered to the buyer in good condition and the latter should inform the vend...