DIMPLEX MOCCA/CUBIC Introduction Please read this information guide carefully to be able to safely install, use and maintain your product. Important Safety Advice 8 When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock and injury t...
Page 7 - BEFORE YOU START
General Information Only use decalcified water in this appliance. This model is designed to be free standing and is normally positioned near a wall. Always ensure that the appliance is sitting on a level surface. Although this heater complies with safety standards, we do not recommend its use on dee...
Page 8 - Operating the Fire; MANUAL CONTROLS
Operating the Fire This section describes how to activate your fire using either the manual controls or remote control. MANUAL CONTROLS The manual controls are located beneath the hinged flap. (Fig.10 for Manual Control lay out) Switch ‘A’:- Controls the electricity supply to the Fire. Note: This sw...
Page 9 - Maintenance; Only use decalcified tap water in this appliance.; decalcified tap water only; Leaving the flame effect on, lift out the fuelbed and water tank.
Maintenance GENERAL TIPS Only use decalcified tap water in this appliance. Always ensure that the appliance is sitting on a level surface. If you intend not using the appliance for longer than 2 weeks, remove and empty the sump and water tank. Once installed, never move this appliance or lay on its ...
Page 10 - Additional Information; AFTER SALES SERVICE; which in turn are not affected by this guarantee.; RECYCLING; Reverse the above steps to reassemble.; Air filter; Gently lift out the fuelbed and place carefully on the ground.
12 Additional Information AFTER SALES SERVICE Your product is guaranteed for two years from the date of purchase. Within this period, we undertake to repair or exchange this product free of charge (excluding lamps & subject to availability) provided it has been installed and operated in accordan...
Page 11 - Troubleshooting
13 Symptom Cause Corrective Action The flame effect will not start. Mains plug is not plugged in. Low water level. Low voltage connector not connected properly. (Fig.5) The Transducer Unit is not sitting correctly in the sump When distilled water is being used, the transducer may not start. Check pl...