Page 3 - Contents; About this Guide
| 3 Contents 1 About this Guide Information Symbols and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2 The S4810 System Introduction . ...
Page 7 - configuration information, refer to the; Information Symbols and Warnings; This documents uses the graphic symbols in
About this Guide | 7 1 About this Guide This guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting, inserting optional modules, and connecting to a power source. After you have completed the hardware installation and power-up of the S4810, for s...
Page 8 - Related Publications; FTOS Configuration Guide for the S4810 System
8 | About this Guide www.dell.com | support.dell.com Related Publications For more information about the S4810 system, refer to the following documents: • FTOS Configuration Guide for the S4810 System • FTOS Command Line Reference Guide for the S4810 System • FTOS Release Notes for the S4810 System ...
Page 9 - Introduction; and stacking identification.
The S4810 System | 9 2 The S4810 System Introduction The Dell Force10 S4810 platform has 640Gbps switching bandwidth. It supports forty-eight 10GbE SFP+ ports, four 40GbE QSFP+ ports, and two power supplies for redundancy. For system access, the S4810 includes an RS-232/RJ-45 console port and a mana...
Page 10 - and optics separately.
10 | The S4810 System www.dell.com | support.dell.com Orderable S4810 Components You can order the S4810 system in several different configurations. You can also order optional modules and optics separately. Table 2-1. Supported Hardware Components Hardware Force10 Catalog Number Dell Part Number 48...
Page 11 - Features
The S4810 System | 11 To successfully install the S4810, ensure that you have the following: • S4810 chassis (or multiple chassis, if stacking) • At least one grounded AC power source per chassis • Cable to connect the AC power source to the chassis (US power cables included) • Mounting brackets for...
Page 12 - show; FTOS Command Line Reference Guide for the S4810 System; LED Displays
12 | The S4810 System www.dell.com | support.dell.com • Hot-swappable redundant power supply • Support for mixed power supply types • 19-inch rack-mountable • Standard 1U chassis height • Up to 128K MAC address entries supported with hardware assisted aging • Supports 12K jumbo frames Ports • Extern...
Page 15 - Site Preparations; Site Selection
Site Preparations | 15 3 Site Preparations The S4810 is suitable for installation as part of a Common Bond Network (CBN). It can be installed in: • network telecommunication facilities • data centers • other locations where the National Electric Code (NEC) applies This chapter contains the following...
Page 16 - Cabinet Placement; Site; Rack Mounting; Environmental Parameters; show logging; FTOS Command Ling Reference Guide for the S4810 System; Power
16 | Site Preparations www.dell.com | support.dell.com Cabinet Placement Install the S4810 only in indoor cabinets designed for use in a controlled environment as described in Site Selection . Do not install the S4810 in outside plant cabinets. The cabinet must meet the following criteria: • Minimum...
Page 17 - Storing Components; Follow these storage guidelines:
Site Preparations | 17 The system is powered-up as soon as the power cord is connected between the system and the power source. CAUTION: Always disconnect the power cable before you service the power supply slots. CAUTION: Use the power supply cord as the main disconnect device on the AC system. Ens...
Page 19 - Install the S4810 Chassis in a Rack or Cabinet; Attach the Mounting Brackets into a Two-Post Rack or Cabinet; To attach the brackets to the system, follow these steps:
Install the S4810 | 19 4 Install the S4810 To install the S4810 system, Dell Force10 recommends completing the installation procedures in the order presented in this chapter. Always handle the S4810 and its components with care. Avoid dropping the system or its Field Replaceable Units (FRUs). This c...
Page 20 - Install the System into a Two-Post Rack or Cabinet
20 | Install the S4810 www.dell.com | support.dell.com Install the System into a Two-Post Rack or Cabinet Ensure that there is adequate clearance surrounding the rack or within the cabinet to permit access and airflow. To install a system into a two-post 19-inch equipment rack using the already atta...
Page 21 - Attach the Mounting Brackets into a Four-Post Rack or Cabinet; To attach the brackets to the rack or cabinet, follow these steps:
Install the S4810 | 21 Attach the Mounting Brackets into a Four-Post Rack or Cabinet The S4810 is shipped with mounting brackets (rack ears) and the required screws for a two-post rack or cabinet installation. To install the S4810 in a four-post rack or cabinet, you must order additional brackets se...
Page 22 - PSU Side
22 | Install the S4810 www.dell.com | support.dell.com 3 Attach the brackets to the PSU sides of the chassis using four screws for each bracket. Attach the bracket so that the “ear” is parallel to the PSU and the outside of the chassis. 4 Attach the long bracket to each side of the chassis using the...
Page 23 - Install the System into a Four-Post Rack or Cabinet; Attach the Ground Cable; To connect the ground cable to the system, follow these steps:
Install the S4810 | 23 Install the System into a Four-Post Rack or Cabinet Ensure that there is adequate clearance surrounding the rack or within the cabinet to permit access and airflow. To install a system into a four-post equipment rack using the already attached mounting brackets, follow these s...
Page 25 - Splitting QSFP Ports to SFP+ Ports; number; Important Points to Know:
Install the S4810 | 25 Splitting QSFP Ports to SFP+ Ports The S4810 supports splitting a single 40G QSFP port into four 10G SFP+ ports using one of the supported breakout cables. For the system to recognize the port type change, you must enter the stack-unit portmode command. For example: stack-unit...
Page 26 - Important Points to Know; When stacking the S4810, keep the following in mind:
26 | Install the S4810 www.dell.com | support.dell.com Important Points to Know When stacking the S4810, keep the following in mind: • Data ports are configured as stacking ports in predefined stacking groups of 40G (four 10G ports or one 40G port). • When a stack-group number is assigned, the ports...
Page 28 - Connect Three S4810 Systems; To connect three S4810 systems in a ring (
28 | Install the S4810 www.dell.com | support.dell.com Figure 4-3. Two S4810 Systems Connected in a Ring Connect Three S4810 Systems To provide backup connectivity and increased data transfer between the systems, Dell Force10 recommends inserting an additional cable between the two units, in a secon...
Page 29 - Supply Power and Power Up the System; Supply power to the S4810 after it is mounted in a rack or cabinet.
Install the S4810 | 29 Figure 4-4. Three S4810s Connected in a Ring Supply Power and Power Up the System Supply power to the S4810 after it is mounted in a rack or cabinet. Dell Force10 recommends re-inspecting your system prior to powering up. Verify that: • the equipment is properly secured to the...
Page 30 - Power Up Sequence; is complete, the PWD LED is steadily lit.; AC Power; DC Power
30 | Install the S4810 www.dell.com | support.dell.com Power Up Sequence When the system powers up, the fans immediately come on at high speed. The fan speed slows as the system boots up. The PWR Light Emitting Diode (LED) blinks until the boot-up sequence is complete. When the boot up is complete, ...
Page 31 - Hot-Swap Units in a Stack; can be already powered up or powered down.
Install the S4810 | 31 Hot-Swap Units in a Stack You can add, remove, or swap S4810 units in an existing stack. The units in the stack and the new units can be already powered up or powered down. All units in a stack must run the same version of the operating system. If you attempt to attach a unit ...
Page 33 - Power Supplies; Components; The following power supply options are available for the S4810:
Power Supplies | 33 5 Power Supplies The S4810 supports two hot-swappable power supplies units (PSUs) with integrated fans that provide cooling for the system. The S4810 supports AC power supplies with two air-flow directions (normal and reversed). Two PSUs are required for full redundancy, but the ...
Page 34 - can remove one power supply without interrupting traffic.
34 | Power Supplies www.dell.com | support.dell.com Figure 5-1. AC Power Supply Figure 5-2. DC Power Supply Power supply 0 (PSU0) is on the left side of the chassis; power supply 1 (PSU1) is on the right side of the chassis. The PSUs in the S4810 are field replaceable. When both power supplies are i...
Page 35 - Install an AC or DC Power Supply; To install an AC or DC power supply, follow these steps:; Replace an AC or DC Power Supply; To replace an AC or DC power supply, follow these steps:
Power Supplies | 35 . NOTE: To comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC Power Ports, use an external SPD at the AC input of the router. Install an AC or DC Power Supply To install an AC or DC power supply, follow these steps: . NOTE: The PSU slides into the slot s...
Page 37 - Fans; Normal—airflow is from the I/O panel to the PSU; YTPNC
Fans | 37 6 Fans The S4810 comes from the factory with one power supply unit (PSU) and two fan modules installed in the chassis. If two or more fans are installed and running, the fan modules and the integrated fan-power supply are hot-swappable. NOTE: To run the system, both slots must have operati...
Page 38 - Install a Fan Module; module slot 1 is on the right side of the chassis.; Replace a Fan Module; To replace a fan module, follow these steps:
38 | Fans www.dell.com | support.dell.com Install a Fan Module The fan modules in the S4810 are field replaceable. Module slot 0 is on the left side of the chassis; module slot 1 is on the right side of the chassis. To install a fan module, follow these steps: Replace a Fan Module To replace a fan m...
Page 39 - Console Ports; lists the console port pinout assignments.; To access the console port, follow these steps:
Console Ports | 39 7 Console Ports You can access the S4810 directly through the console port at the Input/Output (I/O) side of the system. Access the RJ-45 Console Port (RS-232) NOTE: Before starting this procedure, be sure you have a terminal emulation program already installed on your PC. The RS-...
Page 40 - Access the RJ-45 Console Port with a DB-9 Adapter; lists the pin assignments.
40 | Console Ports www.dell.com | support.dell.com Access the RJ-45 Console Port with a DB-9 Adapter If the DTE has a DB-9 interface, you can connect to the console using an RJ-45 to DB-9 adapter along with the RJ-45 rollover cable. Table 7-1 lists the pin assignments. Table 7-1. Pin Assignments Bet...
Page 41 - Specifications; This chapter contains the following sections:; Chassis Physical Design
Specifications | 41 8 Specifications This chapter contains the following sections: • Chassis Physical Design • Agency Compliance Chassis Physical Design Environmental Parameters AC Power Requirements Parameter Specifications Height 1.73 inches (4.4 cm) Width 17.32 inches (44.0 cm) Depth 18.74 inches...
Page 42 - DC Power Requirements; Agency Compliance; Network Equipment Building Systems (NEBS) Compliance
42 | Specifications www.dell.com | support.dell.com DC Power Requirements IEEE Standards The S4810 complies with the following IEEE standards: • 802.3ae 10 Gigabit Ethernet • 802.3ab 1000Base-T • 802.1p L2 Prioritization • 802.1Q VLAN Tagging, Double VLAN Tagging (Q in Q), GVRP • 802.1s Multiple Spa...
Page 43 - USA Federal Communications Commission (FCC) Statement
Specifications | 43 • Use a SPD with the AC power connections in order to protect the AC power supplies from damage from excessive power line surges. • In order to comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC Power Ports, use a SPD at the AC input of the router. WARNI...
Page 44 - Email: EMEA Central Sales; Japan: VCCI Compliance for Class A Equipment
44 | Specifications www.dell.com | support.dell.com This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/European Standard EN 55022. The limits for Class A equipment were derived for commercial and industrial environments...
Page 45 - Korean Certification of Compliance; Safety Standards and Compliance Agency Certifications
Specifications | 45 Korean Certification of Compliance Korean Package Label Safety Standards and Compliance Agency Certifications • CUS UL 60950-1, 2nd Edition • CSA 60950-1-03, 2nd Edition • EN 60950-1, 2nd Edition • EN 60825-1, 1st Edition • EN 60825-1 Safety of Laser Products—Part 1: Equipment Cl...
Page 46 - Product Recycling and Disposal
46 | Specifications www.dell.com | support.dell.com • Japan: VCCI V-3/2011.04 Class A • USA: FCC CFR47 Part 15, Subpart B, Class A Immunity • EN 300 386 v1.5.1:2010 EMC for Network Equipment • EN55022 2006, Class A • EN 55024 1998 + A1: 2001 + A2: 2003 • EN 61000-3-2 Harmonic Current Emissions • EN ...
Page 47 - Contacting the; SD Card Removal; To open the case and remove the SD card, follow these steps:
Specifications | 47 recycling and recovery of WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE. Dell Force10 products, which fall within the scope of the WEEE, are label...
Page 48 - Battery Replacement; The lithium battery is
48 | Specifications www.dell.com | support.dell.com Battery Replacement The lithium battery is not field replaceable . Only authorized personal should remove and replace the battery. If the battery requires replacement, contact Dell Force10 Technical Support. WARNING: ESD damage can occur if compone...
Page 51 - Perchlorate Material; — Special handling may apply.
Specifications | 51 Figure 8-2. The European WEEE Symbol For California: Perchlorate Material — Special handling may apply. See: http://www.dtsc.ca.gov/hazardouswaste/perchlorate The foregoing notice is provided in accordance with California Code of Regulations Title 22, Division 4.5 Chapter 33. Bes...
Page 53 - Technical Support; The iSupport Website; Accessing iSupport Services; The URL for iSupport is
Technical Support | 53 9 Technical Support This chapter contains the following sections: • The iSupport Website • Contacting the Technical Assistance Center • Requesting a Hardware Replacement The iSupport Website iSupport provides a range of documents and tools to assist you with effectively using ...
Page 54 - Contacting the Technical Assistance Center
54 | Technical Support www.dell.com | support.dell.com Contacting the Technical Assistance Center How to Contact Dell Force10 TAC Log in to iSupport at http://www.force10networks.com/support/ and select the Service Request tab. Information to Submit When Opening a Support Case • Your name, company n...
Page 55 - Requesting a Hardware Replacement; To request replacement hardware, follow these steps:
Technical Support | 55 Requesting a Hardware Replacement To request replacement hardware, follow these steps: Step Task 1 Determine the part number and serial number of the component. To list the numbers for all components installed in the chassis, use the show hardware command. 2 Request a RMA numb...