Dell Force10 S4810 System Quick Start Guide Regulatory Model: S4810P
About this Guide 1 About this Guide This document is intended as a Quick Start Guide to get new systems up and running and ready for configuration. For complete installation and configuration information, refer to the following documents: Documentation S4810 Hardware installation and power-up instru...
Installing the Hardware 3 1 Installing the Hardware This guide assumes all site preparation has been performed before installing the chassis. Installing the S4810 Chassis in a Rack or Cabinet To install the S4810 system, Dell Force10 recommends that you complete the installation procedures in the or...
4 Installing the Hardware Install chassis into 2-post rack or cabinet Attach a Ground Cable The S4810 is shipped with 1 M4x0.7 screw for attaching a ground cable to the chassis. The cable itself is not included. Dell Force10 recommends a 6AWG one-hole lug, #10 hole size, 63" spacing (not include...
6 Installing the Hardware Splitting QSFP Ports to SFP+ Ports The S4810 supports splitting a single 40G QSFP port into four 10G SFP+ ports using one of the supported breakout cables (refer to Installing the S4810 System or Release Notes for the S4810 System for a list of supported cables). You must e...
Installing the Hardware 7 Dell Force10 recommends re-inspecting your system prior to powering up. Verify that: • The equipment is properly secured to the rack and properly grounded. • The equipment rack is properly mounted and grounded. • The ambient temperature around the unit (which may be higher ...
8 Installing the Hardware chassis is powered-up; there is no on/off switch. Fans The S4810 comes from the factory with 1 power supply and 2 fan modules installed in the chassis. Both the fan module and the integrated fan-power supply are hot-swappable if a second (redundant) power supply is installe...
10 Installing the Hardware Power Supplies The S4810 is designed to support two hot-swappable power supplies with integrated fans that provide the cooling for the chassis. The S4810 supports AC power supplies with two air-flow directions (Normal and Reversed). Two power supplies are required for full...
Installing the Hardware 11 DC Power Supply Step Task 1 Take the power supply unit out of the shipping box. 2 Using the grab handle, slide the unit into the power supply bay. 3 Tighten the securing screw on the side of the PSU. 4 Attach power cables. 5 The system powers up as soon as the cables are c...
Installing the Software 13 2 Installing the Software Navigating CLI Modes The FTOS prompt changes to indicate the CLI mode. You must move linearly through the command modes, with the exception of the end command which takes you directly to EXEC Privilege mode; the exit command moves you up one comma...
14 Installing the Software Accessing the RJ-45 Console Port with a DB-9 Adapter You can connect to the console using an RJ-45 to DB-9 adapter along with the RJ-45 rollover cable if the DTE has a DB-9 interface. Table 2-1 lists the pin assignments. Default Configuration A version of FTOS is pre-loade...
Installing the Software 15 To view the interfaces in Layer 2 mode, use the show interfaces switchport command in the EXEC mode. Configure a Host Name The host name appears in the prompt. The default host name is force10 . • Host names must start with a letter and end with a letter or digit. • Charac...
Installing the Software 17 Configure the Enable Password Access the EXEC Privilege mode using the enable command. The EXEC Privilege mode is unrestricted by default. Configure a password as a basic security measure. There are two types of enable passwords: • enable password stores the password in th...
18 Installing the Software Assign Interfaces to a VLAN Only interfaces in Layer 2 mode can be assigned to a VLAN using the tagged and untagged commands. Use the switchport command to place an interface in Layer 2 mode. These Layer 2 interfaces can further be designated as tagged or untagged. When an...
Installing the Software 19 Assign an IP address to a VLAN VLANs are a Layer 2 feature. For two physical interfaces on different VLANs to communicate, you must assign an IP address to the VLANs to route traffic between the two interfaces. The shutdown command in INTERFACE mode does not affect Layer 2...
Manual Dell S4810
Dell Manuals
-
Dell 04YJJ6A00
User Manual
-
Dell 04YJJ6A00
Manual
-
Dell 10 Pro
User Manual
-
Dell 10
Manual
-
Dell 1000
User Manual
-
Dell 1000
Manual
-
Dell 1014
User Manual
-
Dell 1000W
User Manual
-
Dell 1000W
Manual
-
Dell 0JH552A01
User Manual
-
Dell 10g
User Manual
-
Dell 1100
User Manual
-
Dell 1100
Manual
-
Dell 11
User Manual
-
Dell 11
Manual
-
Dell 11 Pro
User Manual
-
Dell 110T
User Manual
-
Dell 110T DLT1 Drive
User Manual
-
Dell 1100 Laser Mono Printer
User Manual
-
Dell 1100MP
User Manual