Contents 1 Introduction................................................................................................................................ 11 What’s New in This Release .........................................................................................................................
1 Introduction This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage Version 7. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platform...
Supported SNMP Versions Operating System Supported OMSA SNMP version Windows SNMP v1 Linux SNMP v1 Introduction to the SNMP Reference Guide This reference guide provides a formatted version of the following Management Information Base that are released with the current version of Dell OpenManage.Sec...
Section Topics MIB Group Numbers 6 Operating System Group — defines variables for name, version, service pack, and other information about a system’s operating system 400 7 System Resource Group — defines variables for input/output ports, memory, interrupts, and direct memory access 500 8 Power Grou...
Section Topics MIB Group Number • CMC Power Information • CMC PSU Information • Chassis Alerts • Legacy Alerting How This Guide Defines Technical Terms The following table provides information about where to find definitions for technical terms in this reference guide. Table 7. Where to Find Definit...
Tables This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables. SNMP Tables Most of the MIB objects defined in this reference guide are ...
Access Read-only Table 11. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only Table 12. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defin...
– USB Control Table– IDE Control Table– Diskette Control Table– Network Interface Control Table 3. Variables that make up each table in the group — This section documents the variables for the eight tables that comprise the BIOS group. 4. BIOS Variable Values — This section explains any Server Admin...
All SNMP systems consist of one or more managed systems that provide data through an SNMP agent to a management system. The management system provides a user interface to view data from the managed systems. The management system and managed systems communicate over a network (typically through User ...
ENTERPRISES(1) DELL (674) SNMPv2(6) In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674.The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by ...
2 Instrumentation MIB Version Group The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software.The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersion...
3 Systems Management Software Group The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the...
Table 17. Systems Management Software Build Number Name systemManagementSoftwareBuildNumber Object ID 1.3.6.1.4.1.674.10892.1.100.3 Description Defines the build number of the systems management software. Syntax DellUnsigned16BitRange Access Read-only Table 18. Systems Management Software Descriptio...
Table 22. Systems Management Software URL Name Name systemManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10892.1.100.8 Description Defines the universal resource locator (URL) of the systems management software. Syntax DisplayString (SIZE (0..1024)) Access Read-only Table 23. Systems Management...
Table 27. Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.13 Description Defines the manufacturer of the systems management software. Syntax DellString Access Read-only Systems Management Software Variable Values This ...
4 System State Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords,...
• systemStatePowerUnitStatusCombined • systemStateCoolingUnitStatusCombined • systemStateACPowerSwitchStatusCombined • systemStateRedundantMemoryUnitStatusCombined • systemStateProcessorDeviceStatusCombined • systemStateBatteryStatusCombined • systemStateSDCardUnitStatusCombined • systemStateSDCardD...
Access Read-only Table 37. System State Power Unit State Details Name systemStatePowerUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5 Description Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string repre...
Syntax Octet String (Size (1..128)) Access Read-only Table 41. System State Power Supply Status Combined Name systemStatePowerSupplyStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.9 Description Defines the status of all power supplies in this chassis. Syntax DellStatus Access Read-only Tab...
Table 45. System State Voltage Status Details Name systemStateVoltageStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.13 Description Defines the status of all voltage probes in this chassis. Syntax Octet String (Size (1..128)) Access Read-only Table 46. System State Amperage State Details Na...
Table 49. System State Cooling Unit State Details Name statesystemStateCoolingUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents...
Access Read-only Table 53. System State Cooling Device Status Combined Name systemStateCoolingDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.21 Description This attribute defines the cooling device status of all cooling devices in this chassis. The results is returned as a combined ...
Syntax DellStatus Access Read-only Table 57. System State Temperature Status Details Name systemStateTemperatureStatusDetailsly Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.25 Description Defines the status of all temperature probes in this chassis. The first byte returned represents the status of the...
Syntax Octet String (Size(1..128) Access Read-only Table 61. System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results...
Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on. Syntax Octet String (Size(1..128)) Access Read-only Ta...
Access Read-only Table 69. System State AC Power Cord Status Details Name systemStateACPowerCordStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.37 Description Defines the individual status of all AC power cords for any AC power switches in this chassis. The first byte returned represents th...
Access Read-only Table 73. System State Event Log Status Name systemStateEventLogStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41 Description Defines the overall status of this chassis (ESM) event log. Syntax DellStatus Access Read-only Table 74. System State Power Unit Status Combined Name syst...
Description Lists the status of each cooling unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling unit. The first byte returned represents the status of the first cooling unit, and so on. The bytes have the sam...
Syntax Octet String (Size(1..128)) Access Read-only Table 82. System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50 Description Defines the combined status of all processor devices of this chassis. Syntax DellStatus ...
Table 86. System State SD Card Unit Status Combined Name systemStateSDCardUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.54 Description Defines the combined status of all SD Card units of this chassis. Syntax DellStatus Access Read-only Table 87. System State SD Card Unit Status List ...
5 Chassis Information Group The Chassis Information Group objects provide information about the modular chassis in which a blade system resides. NOTE: This Chassis information is only available for modular/blade systems. For Rack and Tower systems, the information is empty. Currently there is just o...
Chassis Parent Index Reference Name chassisparentIndexReference Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the index (one-based) of the parent chassis of this chassis, if any. A zero (0) means that this chassis is the parent of all other chassis managed by the Server Administra...
Chassis Asset Tag Name Name chassisAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.10 Description Defines the user-assigned asset tag name for this chassis. Syntax DisplayString (SIZE (0..10)) Access Read-write Chassis Service Tag Name Name chassisServiceTagName Object ID 1.3.6.1.4.1.674.108...
Chassis System Name Name chassisSystemName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.15 Description Defines the system name of this chassis. Syntax DellString Access Read-only Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defi...
Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-write Chassis Connection Status Unique Name chassisConnectionS...
Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25 Description Defines the readings and settings of the LED control hardware in the chassis. Syntax DellLEDControlSettings (See Front-Panel LED Control Settings ) Access Read-write Cha...
Chassis Lock Present Name chassisLockPresent Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.30 Description Specifies whether a chassis lock is present on the chassis. Syntax DellBoolean Access Read-only Chassis Host Control Capabilities Unique Name chassishostControlCapabilitiesUnique Object ID 1.3.6.1....
Chassis Watchdog Control Expiry Time Capabilities Unique Name chassiswatchDogControlExpiryTimeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.35 Description Defines the capabilities of the watchdog expiry timer object. Syntax DellWatchDogTimerCapabilities (See Watchdog Timer Capabiliti...
Syntax DellPowerButtonControlSettings (See Power Button Control Settings ) Access Read-write Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40 Description Defines the name of the chassis reseller. Syntax DisplayString (SIZE (0..128)) Access Read-only Chassi...
Access Read-only Chassis NMI Button Control Settings Unique Name chassisNMIButtonControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.45 Description Defines the current reading and allows setting of the NMI button control hardware. Syntax DellNMIButtonControlSettings (See NMI Button Cont...
Access Read-only UUID Table These objects comprise the server administrator definitions for the Universal Unique Identifier (UUID). Table 92. UUID Table Name uUIDTable Object ID 1.3.6.1.4.1.674.10892.1.300.20 Description Defines the UUID table. Syntax SEQUENCE OF UUIDTableEntry Access Not accessible...
Table 96. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 97. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID fo...
Table 100. POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 101. POST Log Record Index Name postLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30...
Table 105. POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines format of the POST log. Syntax DellLogFormat (See Log Format ) Access Read-only Event Log Table Table 106. Event Log Table Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.40 D...
Description Defines the record index of the event log. Syntax DellUnsigned32BitRange Access Read-only Table 110. Event Log State Capabilities Unique Name eventLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.3 Description Defines the capabilities of the object that is writing th...
Description Defines the severity of the event log record. Syntax DellStatus Access Read-only Status Mandatory Table 115. Event Log Date Name Name eventLogDateName Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8 Description Defines the date and time of the event log record. Syntax DellDateName Access Re...
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 119. System BIOS Index Name systemBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2 Description Defines the index (one-based) of the system BIOS of this object. Syntax DellObjectRange Access...
Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 124. System BIOS Release Date Name Name systemBIOSReleaseDateName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1....
Table 128. System BIOS Manufacturer Name Name systemBIOSManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.11 Description Defines the system BIOS manufacturer’s name. Syntax DellString Access Read-only Table 129. System BIOS Characteristics Name systemBIOSCharacteristics Object ID 1.3.6.1.4...
Bit 19 EDD (Enhanced Disk Drive) Specification is supported Bit 20 Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is supported Bit 21 Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in, 360 RPM) is supported Bit 22 Int 13h - 5.25 in / 360 KB Floppy Services are supp...
Bit 1 USB Legacy is supported Bit 2 AGP is supported Bit 3 I2O boot is supported Bit 4 LS-120 boot is supported Bit 5 ATAPI ZIP Drive boot is supported Bit 6 1394 boot is supported Bit 7 Smart Battery supported Syntax DellUnsigned8BitRange Access Read-only Table 131. System BIOS Characteristics Ext ...
Description Defines the status of the firmware. Syntax DellStateSettings Access Read-only Table 139. Firmware Size Name firmwareSize Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.6 Description Defines the image size of the firmware in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsign...
Access Read-only Table 144. Firmware Version Name Name firmwareVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11 Description Defines the version name of the firmware. Syntax DellString Access Read-only Intrusion Table The following objects and attributes describe the different forms of chass...
Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Table 154. Intrusion Location Name Name intrusionLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.8 Description Defines the location name of the intrusion object in this subgroup. Syntax DellString...
Description Defines the type of the baseboard. Syntax DellBaseBoardType Access Read-only Table 164. Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8 Description Defines the name of the type of baseboard. Syntax DellString Access Read-only Table 165. Baseboard L...
Table 169. Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13 Description Defines the baseboard service tag name. Syntax DellString Access Read-only Table 170. Baseboard Piece Part ID (PPID) Name Name baseBoardPiecePartIDName Object ID 1.3.6.1.4.1.6...
Possible Data Values Meaning of Data Value none(0) The hard drive has no fault LED capabilities. unknownCapabilit ies(1) The hard-drive fault LED capabilities are unknown. enableCapable(2) The hard-drive fault LED can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). not...
enableCapable(2) The power button can be enabled (online) or disabled (offline). Table 189. Power Button Control Settings Variable Name : DellPowerButtonControlSettings Data Type: IntegerPossible Data Values Meaning of Data Value none(0) The power button has no settings capabilities. unknown(1) The ...
Data Type: IntegerPossible Data Values Meaning of Data Value other(1) The firmware type is other than following values. unknown(2) The firmware type is unknown. systemBIOS(3) The firmware type is System BIOS embeddedSystemMa nagementContro ller(4) The firmware type is Embedded System Management Cont...
6 Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system.The following objects describe the fields for Operating System Gro...
Access Read-only Table 201. Operating System Memory State Settings Name operatingSystemMemoryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.3 Description Defines the state and allows the setting of the operating system memory. Syntax DellStateSettings Access Read-write Table 202. Operating...
Table 206. Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8 Description Defines the available page file memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 207. Operating System Me...
7 System Resource Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes System Resource Group Tables that track variables such as the owner, ports, system memory, interrupts, and direct m...
Description Defines the type of this system map. Syntax DellSystemResourceMapType ( System Resource Map Type ) Access Read-only System Resource Owner Table Table 217. System Resource Owner Table Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20 Description Defines the System Res...
Table 221. System Resource Owner State Capabilities Name systemResourceOwnerStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.3 Description Defines the capabilities of this system resource owner. Syntax DellStateCapabilities Access Read-only Table 222. System Resource Owner State Settings...
Description Defines the share disposition of the system resource I/O port. Syntax DellResourceShareDisposition ( Resource Share Disposition ) Access Read-only Table 237. System Resource I/O Port Starting Address Name systemResourceIOPortStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.8 De...
Syntax DellObjectRange Access Read-only Table 246. System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.7 Description Defines the share disposition of the system resource memory. Syntax DellResourceShareDisposition ( Resource S...
Access Read-write Table 256. System Resource Interrupt Status Name systemResourceInterruptStatus Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.5 Description Defines the status of this system resource interrupt. Syntax DellStatus Access Read-only Table 257. System Resource Interrupt Owner Index Referenc...
Table 261. System Resource Interrupt Trigger Name systemResourceInterruptTrigger Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10 Description Defines the interrupt trigger of the system resource interrupt. Syntax DellResourceInterruptTrigger ( Resource Interrupt Trigger ) Access Read-only System Resour...
Access Read-only Table 266. System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA. Syntax DellStateCapabilities Access Read-only Table 267. System Resource DMA State...
Table 271. System Resource DMA Maximum Transfer Size Name systemResourceDMAMaximumTransferSize Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.8 Description Defines the maximum size of a memory transfer in bytes for the system resource DMA. Syntax DellUnsigned32BitRange Access Read-only Table 272. System...
8 Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes. NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems that ...
Table 289. Power Supply Count for Redundancy Name powerSupplyCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.6 Description Defines the total number of power supplies required for this power unit to have redundancy. Syntax DellString Access Read-only Table 290. Power Unit Name Name powe...
Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Table 300. Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerS...
Access Read-only Table 305. Power Supply Configuration Error Type Name powerSupplyConfigurationErrorType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.12 Description Defines the type of configuration error reported by the power supply sensor. Syntax DellPowerSupplyConfigurationErrorType ( Power Supply ...
Table 315. Voltage Probe Reading Name voltageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6 Description Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading. When the value for voltageProbeType is voltageP...
Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete.When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for t...
Access Read-only Table 330. Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.3 Description Defines the capabilities of the amperage probe. Syntax DellStateCapabilities Access Read-only Table 331. Amperage Probe State Settings Name amper...
Access Read-only Table 334. Amperage Probe Type Name amperageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.7 Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Table 335. Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6...
Table 339. Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.12 Description Defines the user-assigned value of the amperage probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 340. Am...
AC Power Switch Table Table 344. AC Power Switch Table Name aCPowerSwitchTable Object ID 1.3.6.1.4.1.674.10892.1.600.40 Description Defines the AC Power Switch Table. Syntax SEQUENCE OF ACPowerSwitchTableEntry Access Not accessible Table 345. AC Power Switch Table Entry Name aCPowerSwitchTableEntry ...
Syntax DellACPowerSwitchCapabilities Access Read-only Table 349. AC Power Switch Settings Name aCPowerSwitchSettings Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.4 Description Defines the settings of this AC power switch. Syntax DellACPowerSwitchSettings Access Read-write Table 350. AC Power Switch Re...
Table 354. AC Power Switch Status Name aCPowerSwitchStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.9 Description Defines the status of this AC power switch. Syntax DellStatus Access Read-only AC Power Cord Table Table 355. AC Power Cord Table Name aCPowerCordTable Object ID 1.3.6.1.4.1.674.10892....
Access Read-only Table 359. AC Power Cord State Capabilities Name aCPowerCordStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.3 Description Defines the capabilities of this AC power cord. Syntax DellACPowerCordStateCapabilities Access Read-only Table 360. AC Power Cord State Settings Nam...
Battery Table Table 364. Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Table 365. Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.1 Descrip...
Table 369. Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-write Table 370. Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Descrip...
Table 379. Power Usage Status Name powerUsageStatus Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.5 Description Defines the status of the power usage information. Syntax DellStatus Access Read-only Table 380. Power Usage Entity Name Name powerUsageEntityName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.6...
Table 384. Power Usage Peak Watts Start Date Name Name powerUsagePeakWattsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.10 Description Defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute. Syntax DellDateName Access Rea...
Table 389. Power Usage Idle Power Name powerUsageIdlePower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.15 Description Defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only ...
Table 394. Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.20 Description Defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. Syntax De...
Access Read-only Table 399. Power Profile Index Name powerProfileIndex Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.2 Description Defines the index (one-based) of the power profile information. Syntax DellObjectRange Access Read-only Table 400. Power Profile Supported Profiles Name powerProfileSupport...
Table 404. Power Profile Custom Memory Management Capabilities Name powerProfileCustomMemoryManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.7 Description Defines the custom memory power and performance management capabilities that are available for the Custom power profile. Syntax ...
unknown(1) The power supply’s capabilities are unknown. onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The power supply’s capabilities are not ready. Table 409. Power Supply State Settings Unique Variable Name: ...
powerSupplyTypeIsLinear(3) The power supply type is a linear power supply. powerSupplyTypeIsSwitching(4) The power supply type is a switching power supply. powerSupplyTypeIsBattery(5) The power supply type is a battery. powerSupplyTypeIsUPS(6) The power supply type is an uninterruptable power supply...
amperageProbeTypeIsOther(1) The amperage probe type is not one of the following: amperageProbeTypeIsUnknown(2) The amperage probe type is unknown (not known or not monitored). amperageProbeTypeIs1Point5Volt(3) The amperage probe type is a 1.5-ampere (A) probe. amperageProbeTypeIs3Point3volt(4) The a...
NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Memory power and performance management type is Maximum Performance. mhz1333(2) Memory power and performance is 1333 MHz. . mhz1067(4) Memory power and performance is 10...
9 Thermal Group The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes. Ther...
Syntax TableEntry Access Read-only Table 432. Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units. Syntax DellObjectRange Access Read-only Table 433. Cooling Unit State Capabilities Name coolingUnitStateCapa...
Table 437. Cooling Unit Name Name coolingUnitName Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.7 Description Defines the cooling unit name in this chassis. Syntax DellString Access Read-only Table 438. Cooling Unit Status Name coolingUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.8 Description ...
Access Read-only Table 442. Cooling Device Index Name coolingDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.2 Description Defines the index of cooling devices in this chassis. Syntax DellObjectRange Access Read-only Table 443. Cooling Device State Capabilities Name coolingDeviceStateCapabili...
Access Read-only Table 447. Cooling Device Type Name coolingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.7 Description Defines the cooling device type. Syntax DellCoolingDeviceType ( Cooling Device Type ) Access Read-only Table 448. Cooling Device Location Name Name coolingDeviceLocationNam...
Table 452. Cooling Device Lower Noncritical Threshold Name coolingDeviceLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.12 Description Defines the user-assigned value of the fan’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 453. Cooling Devic...
Description Defines the probe capabilities of the cooling device. Syntax DellProbeCapabilities Access Read-only Table 458. Cooling Device Discrete Reading Name coolingDeviceDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.18 Description Defines the reading for a voltage probe of type cooli...
Access Read-only Table 462. Temperature Probe Index Name temperatureProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.2 Description Defines the index of temperature probes in this chassis. Syntax DellObjectRange Access Read-only Table 463. Temperature Probe State Capabilities Name temperaturePro...
Access Read-only Table 467. Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.7 Description Defines the temperature probe type. Syntax DellTemperatureProbeType ( Temperature Probe Type ) Access Read-only Table 468. Temperature Probe Location Name Name temper...
Table 472. Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.12 Description Defines the user-assigned value of the temperature probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Tabl...
Thermal Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 477. Cooling Device Type Variable Name: DellCoolingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther(1) The co...
10 User Security Group The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems. User Security Group Table The User Security Group defines objects in the User Security MIB table. ...
Table 485. User Security Index Name userSecurityIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.2 Description Defines the user security index. Syntax DellObjectRange Access Read-only Table 486. User Security User Name Name userSecurityUserName Object ID 1.3.6.1.4.1.674.10892.1.800.1.3 Description Defi...
11 Remote Flash BIOS Group The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates on the system. Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects i...
Table 492. Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system. Syntax DellObjectRange Access Read-only Table 493. Remote Flash BIOS State Capabilities Unique Name remoteFlashBI...
Table 497. Remote Flash BIOS Completion Code Name remoteFlashBIOSCompletionCode Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.7 Description Defines the completion code of the last BIOS update. Syntax DellRemoteFlashBIOSCompletionCode ( Remote Flash BIOS Completion Code ) Access Read-only Table 498. Rem...
canceled(8) The remote flash BIOS has been canceled. pending(16) The remote flash BIOS update is pending. other(32) The remote flash BIOS state/setting is not one of the previous values. Table 501. Remote Flash BIOS Completion Code Variable Name: DellRemoteFlashBIOSCompletionCode Data Type: Integer ...
12 Port Group The Port Group provides information about the different types of ports that may be present in your system. This management information base (MIB) group also provides information about the capabilities, states, and settings that are possible for each port. Port Group Tables The followin...
Access Read-only Table 509. Pointing Port Security State Name pointingPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.10.6 Description Defines the security settings of the pointing port. Syntax DellPortSecurityState Access Read-only Table 510. Pointing Port Connector Type Name pointingPortC...
Table 518. Keyboard Port State Settings Name keyboardPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.4 Description Defines the state and settings of the keyboard port. Syntax DellStateSettings Access Read-only Table 519. Keyboard Port Status Name keyboardPortStatus Object ID 1.3.6.1.4....
Table 523. Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Table 524. Processor Port Table Na...
Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Table 528. Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port. Syn...
Syntax DellProcessorPortConnectorType (See Processor Port Connector Types ) Access Read-only Table 533. Processor Port Name Name processorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.8 Description Defines name of the processor port. Syntax DellString Access Read-only Table 534. Processor Por...
Table 537. Memory Device Port Chassis Index Name memoryDevicePortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 538. Memory Device Port Index Name memoryDevicePortIndex Object ID 1.3....
Table 542. Memory Device Port Security State Name memoryDevicePortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.6 Description Defines the security settings of the memory device port. Syntax DellPortSecurityState Access Read-only Table 543. Memory Device Port Connector Type Name memoryDev...
Table 547. Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis...
Table 551. Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Table 552. Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1...
Table 556. Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port. Syntax DellMonitorPortConnectorTypes (See Monitor Port Connector Types ) Access Read-only Table 557. Monitor Port Name Name m...
Syntax DellStatus Access Read-only Table 566. SCSI Port Security State Name sCSIPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.6 Description Defines the security settings of the SCSI port. Syntax DellPortSecurityState Access Read-only Table 567. SCSI Port Connector Type Name sCSIPortC...
Table 575. Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-write Table 576. Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4...
Table 580. Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9 Description Defines the pinout of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Table 581. Parallel Port Capabilities Unique Name parallelPortCapabil...
Serial Port Table Table 585. Serial Port Name serialPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.80 Description Defines the Serial Port Table. Syntax IntegerSerialPortTableEntry Access Not accessible Table 586. Serial Port Table Entry Name serialPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1...
Table 589. Serial Port State Capabilities Name serialPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.3 Description Defines the capabilities of the serial port. Syntax DellStateCapabilities Access Read-only Table 590. Serial Port State Settings Name serialPortStateSettings Object ID...
Table 594. Serial Port Name Name serialPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.8 Description Defines the name of the serial port. Syntax DellString Access Read-only Table 595. Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description...
Syntax DellStateCapabilities Access Read-only Table 604. USB Port State Settings Name uSBPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4 Description Defines the state and settings of the USB port. Syntax DellStateSettings Access Read-write Table 605. USB Port Status Name uSBPortStatu...
Access Read-only Port Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 609. Pointing Port Connector Type Variable Name: DellPointingPortConnectorType Data Type : Integer Possible Data Values Meaning of Data Value co...
connectorPortTypeIsUnknown(2) The keyboard port connector type is unknown. connectorPortTypeIsMiniDIN(3) The keyboard port connector type is a mini DIN. connectorPortTypeIsMicroDIN(4) The keyboard port connector type is a MicroDIN. connectorPortTypeIsPS2(5) The keyboard port connector type is PS/2. ...
connectorPortTypeIsSIMM(3) The memory device port connector type is a single in-line memory module (SIMM). connectorPortTypeIsSIP(4) The memory device port connector type is a SIP. connectorPortTypeIsAChip(5) The memory device port connector type is a chip. connectorPortTypeIsDIP(6) The memory devic...
connectorPortTypeIsDIN68pin(5) The SCSI port connector type is a DIN 68-pin. 183
13 Device Group The Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID. Device Tables The following management information base (MIB) tables define objects in the De...
Syntax DellStatus Access Read-only Table 622. Pointing Port Index Reference Name pointingPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.6 Description Defines the index to the pointing port in this chassis. Syntax DellObjectRange Access Read-only Table 623. Pointing Device Type Name p...
Access Read-only Table 632. Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis. Syntax DellStatus Access Read-only Table 633. Keyboard Device Type Name Name keyb...
Description Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 648. Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.12 D...
Syntax DellString Access Read-only Table 653. Processor Device Core Count Name processorDeviceCoreCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17 Description Defines the number of processor cores detected for the processor device. Syntax DellUnsigned32BitRange Access Read-only Table 654. Proces...
Access Read-only Table 657. Processor Device Extended Capabilities Name processorDeviceExtendedCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21 Description This attribute defines extended capabilities of the processor device. This attribute is a bit field where a bit has the meaning defin...
Table 660. Processor Device Model Name Name processorDeviceModelName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24 Description Defines the model of the processor device. Syntax DellString Access Read-only Table 661. Processor Device Stepping Name Name processorDeviceSteppingName Object ID 1.3.6.1.4...
Access Read-only Table 665. Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe. Syntax DellObjectRange Access Read-only Table 666. Processor Device Status State Cap...
Table 670. Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe. Syntax DellString Access Read-only Table 671. Processor Device Status Port Index Reference...
Syntax DellObjectRange Access Read-only Table 675. Cache Device Index Name cacheDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2 Description Defines the index of the cache device in this chassis. Syntax DellObjectRange Access Read-only Table 676. Cache Device State Capabilities Name cacheDe...
Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 686. Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Define...
Syntax DellCacheDeviceECCType (See Cache Device ECC Type ) Access Read-only Table 691. Cache Device Associativity Name cacheDeviceAssociativity Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.18 Description Defines the type of associativity in use by the cache device. Syntax DellCacheDeviceAssociativity...
Syntax DellStatus Access Read-only Table 701. Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-onl...
Description Defines the bank location name of the memory device. Syntax DellString Access Read-only Table 706. Memory Device Type Details Name memoryDeviceTypeDetails Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11 Description Defines the detailed type of the memory device. Syntax DellMemoryDeviceTyp...
Access Read-only Table 711. Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16 Description Defines the total number of bits, including ECC, used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Table 712. Memory Device Tota...
Table 715. Memory Device Failure Modes Name memoryDeviceFailureModes Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20 Description Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK. It is a bit field that can be used to report more than one type of failure m...
Table 720. Memory Device Speed Name Name memoryDeviceSpeedName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25 Description This attribute defines the speed of the memory device in string format with units specified in string. Syntax DellString Access Read-only Table 721. Memory Device Rank Name memor...
Access Read-only Table 729. Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address. Syntax DellObjectRange Access Read-only Table 730. Memory D...
Access Read-only Table 734. Memory Device Mapped Address Ending Address Name memoryDeviceMappedAddressEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.11 Description Defines the physical ending address in KB of the memory device mapped address. Syntax DellUnsigned64BitRange Access Read-only...
Description Defines the index of the generic device in this chassis. Syntax DellObjectRange Access Read-only Table 739. Generic Device State Capabilities Name genericDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.3 Description Defines the capabilities of the generic device. Synt...
Table 744. Generic Device Name Name genericDeviceName Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8 Description Defines the name of the generic device. Syntax DellString Access Read-only PCI Device Table Table 745. PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Descri...
Access Read-only Table 749. PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3 Description Defines the capabilities of the PCI device. Syntax DellStateCapabilities Access Read-only Table 750. PCI Device State Settings Name pCIDeviceStateSettin...
Table 754. PCI Device Manufacturer Name Name pCIDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.8 Description Defines the name of the PCI device manufacturer. Syntax DellString Access Read-only Table 755. PCI Device Description Name Name pCIDeviceDescriptionName Object ID 1.3.6.1....
Description Defines the common configuration space header of the PCI device. Syntax Octet String (SIZE(0.1025)) Access Read-only Network Device Table Table 770. Network Device Table Name networkDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.90 Description Defines the Network Device Table. Syntax...
Table 774. Network Device Status Name networkDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.3 Description Defines the status of the network device. Syntax DellStatus Access Read-only Table 775. Network Device Connection Status Name networkDeviceConnectionStatus Object ID 1.3.6.1.4.1.674.10...
Description Defines the service name of the network device. Syntax DellString Access Read-only Table 780. Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.9 Description Defines the path to the binary image of the driver for the n...
Access Read-only Table 785. Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.14 Description Defines the IP address of the DHCP server that was used to obtain the IP address of the network device if DHCP was used to configure the ...
Description Defines if TOE is enabled for the network device. Syntax DellBoolean Access Read-only Table 796. Network Device RDMA Capability Flags Name networkDeviceRDMACapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25 Description Defines the Remote Direct Memory Access (RDMA) capability...
Managed System Services Device Table Table 800. Managed System Services Device Table Name Object ID 1.3.6.1.4.1.674.10892.1.1100.100 Description Defines the Managed System Services Device Table. Syntax Sequence of ManagedSystemServicesDeviceTable Access Not accessible Table 801. Managed System Servi...
Syntax DellStatus Access Read-only Table 805. Managed System Services Device Type Name managedSystemServicesDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.4 Description Defines the type of the managed system services device. Syntax DellManagedSystemServicesDeviceType (See Managed System Ser...
Syntax DellStatusRedundancy Access Read-only Table 815. SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.6 Description Defines the total number of SD Card devices required for this SD Card unit to have full redundancy. Syntax DellObject...
Access Read-only Table 825. SD Card Device Config Settings Name sdCardDeviceConfigSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6 Description Defines the configuration settings of the SD Card device. Syntax DellSDCardDeviceConfigSettings Access Read-only Table 826. SD Card Device Location Na...
Table 830. SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.11 Description Defines the index to the associated SD Card unit if the SD Card device is part of a SD Card unit. Syntax DellObjectRange Access Read-only Table 831. SD Card ...
deviceTypeIsMathP rocessor(4) The processor device type is a math processor. deviceTypeIsDSP(5 ) The processor device type is a digital signal processor. deviceTypeIsAVide oProcessor(6) The processor device is a video processor. Table 837. Processor Upgrade Information Variable Name: DellProcessorUp...
processorUpgradeI sBySocket939(18) Upgrade is by Socket 939. processorUpgradeI sBySocketmPGA604( 19) Upgrade is by Socket mPGA604. processorUpgradeI sBySocketLGA771(2 0) Upgrade is by Socket LGA771. processorUpgradeI sBySocketLGA775(2 1) Upgrade is by Socket LGA775. processorUpgradeI sBySocketS1(22)...
deviceAssociativi tyIsTwoWaySetAsso ciative(4) Device is two-way set associative. deviceAssociativi tyIsFourWaySetAss o ciative(5) Device is four-way set associative. deviceAssociativi tyIsFullyAssociat ive (6) Device is fully associative. deviceAssociativi tyIsEightWaySetAs so ciative(7) Device is ...
deviceSRAMTypeIsO ther(1) Device SRAM type is not one of the following: deviceSRAMTypeIsU nknown(2) Device SRAM type is unknown. deviceSRAMTypeIsN onBurst(3) Device SRAM type is nonburst. deviceSRAMTypeIsB urst(4) Device SRAM type is burst. deviceSRAMTypeIsP ipeBurst(5) Device SRAM type is pipeburst...
deviceFormFactorI sSRIMM(14) Device form factor is SRIMM. deviceFormFactorI sFBDIMM(15) Device form factor is FB-DIMM. Table 848. Memory Device Type Variable Name: DellMemoryDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) Device type is not one of the f...
deviceTypeIsDDR2F BDIMM(20) Device type is DDR2 FB-DIMM. deviceTypeIsDDR3( 24) Device type is DDR3. deviceTypeIsFBD2( 25) Device type is FBD2. Table 849. Memory Device Type Details Variable Name: DellMemoryDeviceTypeDetails Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeDeta...
standby(256) Device is in standby mode. Table 862. SD Card Device Card Licensed Variable Name: DellSDCardDeviceCardLicensed Data Type: Integer Possible Data Values Meaning of Data Value unlicensed(0) SD card is not licensed by system vendor. licensed(1) SD card is licensed by system vendor. ipmiRead...
14 Slot Group The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots. System Slot Group Table The System Sl...
Table 866. System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis. Syntax DellObjectRange Access Read-only Table 867. System Slot State Capabilities Unique Name systemSlotStateCapabilitiesUniqu...
Table 871. System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7 Description Defines the type of the system slot. Syntax DellSystemSlotType ( System Slot Type ) Access Read-only Table 872. System Slot External Slot Name Name systemSlotSlotExternalSlotName Object ID 1.3.6...
Table 876. System Slot Hot-Plug Bus Width Name systemSlotHotPlugBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12 Description Defines the bus width of the hot-plug system slot. Syntax DellSystemSlotHotPlugBusWidth ( Hot-Plug Bus Width ) Access Read-only Table 877. System Slot Hot-Plug Slot Spe...
systemSlotHotPlugCanSignal PowerFault(16) Power on fault (and corresponding LED) can be detected due to a short or overcurrent. systemSlotHotPlugCanSignal AdapterPresent(32) Adapter (card) present in slot (may not be powered) can be detected. systemSlotHotPlugCanSignal PowerButtonPressed(64) The sys...
systemSlotHotPlugAdapterIsPresent (32) Adapter (card) present in slot (may not be powered). systemSlotHotPlugAdapterPresentAnd PoweredOn(36) Adapter (card) present in slot and powered. systemSlotHotPlugPowerButtonPressed (64) The system slot power button pressed to signal a toggle of the power state...
15 Memory Group The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory. Physical Memory Tables The following manage...
Table 891. Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array. Syntax DellStateSettings Access read-write Table 892. Physical Memory Array Status Name physicalMemoryArrayS...
Table 896. Physical Memory Array Maximum Size Name physicalMemoryArrayMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.9 Description Defines the size in KB of the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Table 897. Physical Memory Array Total Number Sockets Name p...
Table 901. Physical Memory Array ECC Error Noncritical Threshold Name physicalMemoryArrayECCErrorNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.14 Description Defines the value of the physical memory array ECC error noncritical threshold. Syntax DellSigned32BitRange Access read-wri...
Table 905. Physical Memory Array Mapped Chassis Index Name physicalMemoryArrayMappedchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 906. Physical Memory Array Mapped Index Name physica...
Table 910. Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis. Syntax DellObjectRange Access Read-only Table 911. Physical Memory Array Mapped...
Table 919. Physical Memory Configuration State Settings Name physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4 Description Defines the state settings of the physical memory configuration. Syntax DellPhysicalMemoryConfigStateSettings Access Read-write Table 920. Physical...
Table 924. Physical Memory Configuration MOM Settings Name physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9 Description Defines the Memory Operating Mode settings of the physical memory. Syntax DellPhysicalMemoryConfigMOMSettings Access Read-only Physical Memory Logging ...
Table 928. Physical Memory Logging Index Name physicalMemoryLoggingIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.2 Description Defines the index (one-based) of the physical memory logging. Syntax DellObjectRange Access Read-only Table 929. Physical Memory Logging Capabilities Name physicalMemory...
Table 937. Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit. Syntax DellStateSettings Access Read-write Table 938. Redundant Memory Unit Redundancy Status Name ...
Table 946. Physical Memory Card State Settings Name physicalMemoryCardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.4 Description Defines the state settings of the Physical Memory Card. Syntax DellStateSettings Access Read-write Table 947. Physical Memory Card Status Name physicalMemoryC...
Access Read-only Table 951. Physical Memory Card Physical Memory Array Index Reference Name physicalMemoryCardPhyMemArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.9 Description Defines the index (one-based) of the Physical Memory Array Table entry for the physical memory array with ...
Table 959. Physical Memory Logging Settings Variable Name: DellPhysicalMemoryLoggingSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging settings enabled. unknown Capabilities(1) Logging capabilities are unknown. The logging settings are: ena...
16 BIOS Setup Control Group Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interfa...
Access Read-only Table 967. BIOS Setup Control Numeric Lock Control Capabilities Name bSUCnumLockControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.6 Description Defines the capabilities of the numeric lock. Syntax DellStateCapabilities Access Read-only Table 968. BIOS Setup Control Num...
Access Read-only Table 972. BIOS Setup Control Processor Serial Number Control Settings Name bSUCprocessorSerialNumberControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.11 Description Defines the state of the processor serial number. Syntax DellStateSettings Access Read-only Table 973. BIOS...
Access Read-only Table 977. BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only Table 978. BIOS Setup Control Speaker Control Name Name bSUCspeaker...
Syntax DellStatus Access Read-only Table 982. BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN. Syntax DellString Access Read-only Table 983. BIOS Setup C...
Syntax DellString Access Read-only Table 987. BIOS Setup Control Administrator Password Control Capabilities Unique Name bSUCadministratorPasswordControlCapabilities Unique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.26 Description Defines the capabilities of the administrator password control. Synt...
Description Defines the setup BIOS name of the new administrator password. To set a new administrator password, you must have successfully set the current administrator password immediately preceding this password change. Syntax DellString Access Read-write Table 992. BIOS Setup Control User Passwor...
Description Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user password immediately preceding this password change. Syntax DellString Access Read-write Table 997. BIOS Setup Control TPM Security Control Capabilities Nam...
SCSI Control Table Table 1001. SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table. Syntax SCSIControlTableEntry Access Not accessible Table 1002. SCSI Control Table Entry Name sCSIControlTabl...
Syntax DellStateCapabilities Access Read-only Table 1006. SCSI Control Settings Name sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4 Description Defines the state of the SCSI controller. Syntax DellStateSettings Access Read-only Table 1007. SCSI Control Status Name sCSIControlStatu...
Access Not accessible Index parallelPortControlchassisIndex , parallelPortControlIndex Table 1011. Parallel Port Control Chassis Index Name parallelPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange ...
Access Read-only Table 1016. Parallel Port Control Name Name parallelPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6 Description Defines the setup BIOS name of the parallel port. Syntax DellString Access Read-only Table 1017. Parallel Port Control Mode Capabilities Unique Name parallel...
Index serialPortControlchassisIndex , serialPortControlIndex Table 1021. Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Table 1022. Seria...
Table 1026. Serial Port Control Name Name serialPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6 Description Defines the setup BIOS name of the serial port. Syntax DellString Access Read-only USB Control Table These objects enable you to track the attributes of your Universal Serial Bus...
Syntax DellObjectRange Access Read-only Table 1031. USB Control Capabilities Name usbControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3 Description Defines the capabilities of the USB. Syntax DellStateCapabilities Access Read-only Table 1032. USB Control Settings Name usbControlSettin...
Access Not accessible Table 1036. IDE Control Table Entry Name ideControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1 Description Defines the IDE Control Table entry. Syntax IdeControlTableEntry Access Not accessible Index ideControlchassisIndex , ideControlIndex Table 1037. IDE Control Ch...
Access Read-only Table 1041. IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only Table 1042. IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6...
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1046. Diskette Control Index Name disketteControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2 Description Defines the index of the diskette controllers in this chassis. Syntax DellObjectRa...
Network Interface Control Table These MIB objects enable you to track the attributes of the NIC card for your system. Table 1051. Network Interface Control Table Name networkInterfaceControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.80 Description Defines the Network Interface Control Table. Synta...
Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Network Interface Control Capabilities ) Access Read-only Table 1056. Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.4 Description Defines the control settings ...
Description Defines the recommended display order of the BIOS setting within its BIOS setting group. Syntax DellUnsigned32BitRange Access Read-only Table 1071. BIOS Setting Group Display Name Name biosSettingGroupDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.11 Description Defines the disp...
enableCapable(2) Setup BIOS can enable the serial port. com1Capable(4) Setup BIOS can support serial port 1. enableAndCom1Capable(6) Setup BIOS can enable serial port 1. com2Capable(8) Setup BIOS can support serial port 2. enableAndCom2Capable(10) Setup BIOS is capable of enabling serial port 2. com...
17 Local Response Agent Group The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA). The LRA allows systems managers to predetermine how a system running the server administrator responds to a particular event type, such as the loss ...
Syntax LRAGlobalSettingsTableEntry Access Not accessible Index lRAGlobalchassisIndex Table 1096. LRA Global Chassis Index Name lRAGlobalchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table ...
Description Defines the set of thermal shutdown capabilities that are supported by the LRA. Syntax DellLRAThermalShutdownCapabilitiesUnique Access Read-only Table 1101. LRA Global Thermal Shutdown State Settings Unique Name lRAGlobalThermalShutdownStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892....
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1105. LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index. The action number in...
Syntax DisplayString (SIZE (0..256) Access Read-write Table 1107. LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.4 Description Defines the LRA settings. Syntax DellLocalResponseAgentSettingsUnique ( Local Response Agent Settings Unique ...
warningCapable(4) The LRA can carry out chassis-determined action(s) when a warning condition is detected. enableOnWarningCapable(6) The LRA enables activation of chassisdetermined action(s) when a warning condition is detected. failureCapable(8) The LRA can carry out chassis-determined action(s) wh...
18 Cost of Ownership Group The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accura...
Syntax DellDateName Access Read-write Table 1118. COO Acquisition Purchase Order Name cooAquisitionPurchaseOrder Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.6 Description Defines the purchase order number of the system. Syntax DellUnsigned32BitRange Access Read-write Table 1119. COO Acquisition Purc...
Access Read-only Table 1123. COO Cost Center Information Vendor Name Name cooCostCenterInformationVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.11 Description Defines the cost center name of the system. Syntax DellCostofOwnershipString Access Read-write Table 1124. COO User Information User...
Access Read-write Table 1128. COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-write Table 1129. COO Own...
Access Read-write Table 1133. COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system. Syntax DellCooHourDayDurationType (See COO Hour Day Duration Type ) Access Read-write Table 1134. CO...
Access Read-write Table 1138. COO Outsourcing Provider Fee Name Name cooOutsourcingProviderFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26 Description Defines any additional outsourcing charge for service. Syntax DellCostofOwnershipString Access Read-write Table 1139. COO Outsourcing Provider...
Access Read-write Table 1143. COO Box Central Processing Unit (CPU) Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.31 Description Defines the name of the CPU serial number for the system. Syntax DellCostofOwnershipString Access Read-write Table 1144. CO...
Access Read-write Table 1148. COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-write Table 1149. COO Depreciation Pe...
Table 1157. COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed. Syntax DellBoolean Access Read-write Table 1158. COO Service Contract Type Name Name cooService...
Table 1166. COO Cost Event Log Duration Type Name cooCostEventLogDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.5 Description Defines the duration type of the event for this system. Syntax DellCOOHourDayDurationType (See COO Hour Day Duration Type ) Access Read-write Table 1167. COO Cost E...
Table 1170. COO Warranty Chassis Index Name cooWarrantychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-write Table 1171. COO Warranty Index Name cooWarrantyIndex Object ID 1.3.6.1.4.1.674.10892.1...
Table 1175. COO Warranty End Date Name Name cooWarrantyEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.6 Description Defines the warranty end date for this system. Syntax DellDateName Access Read-write Table 1176. COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600....
Table 1179. COO Lease Information Chassis Index Name cooLeaseInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1180. COO Lease Information Index Name cooLeaseInformationIndex ...
Table 1184. COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-write Table 1185. COO Lease Information End Date Name ...
Description Defines the lease information index number to reference the schedule number. Syntax DellUnsigned32BitRange Access Read-write Table 1194. COO Schedule Number Description Name Name cooScheduleNumberDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.5 Description Describes the sche...
Access Read-only Table 1198. COO Options Index Name cooOptionsIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.2 Description Defines the index (one-based) of the option information for this system. Syntax DellObjectRange Access Read-only Table 1199. COO Options State Name cooOptionsState Object ID ...
Table 1207. COO Maintenance Start Date Name Name cooMaintenanceStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.4 Description Defines the start date for maintenance on this system. Syntax DellDateName Access Read-write Table 1208. COO Maintenance End Date Name Name cooMaintenanceEndDateName...
Description Defines the number of repairs that this system has undergone. Syntax DellCostofOwnershipString Access Read-write Table 1217. COO Repair Vendor Name Name cooRepairVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5 Description Defines the name of the vendor that repairs this system. ...
Access Read-only Table 1221. COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information. Syntax DellObjectRange Access Read-only Table 1222. COO Support Information State...
Access Read-write Table 1226. COO Support Information Fix Type Name Name cooSupportInformationFixTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.7 Description Defines the method used to fix the problem. Syntax DellCostofOwnershipString Access Read-write COO Trouble Ticket Table The MIB objects...
Table 1230. COO Trouble Ticket Index Name cooTroubleTicketIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.2 Description Defines the index (one-based) of the system’s trouble ticket information. Syntax DellObjectRange Access Read-only Table 1231. COO Trouble Ticket State Name cooTroubleTicketState...
19 Remote Access Group The Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to providing general information about the capabilities and settings of the remote access hardware, this group provides information about administrativ...
Access Read-only Table 1241. Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware. Syntax DellObjectRange Access Read-only Table 1242. Remote Access Type Name remoteAccessType O...
Table 1246. Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7 Description Defines the name of the product providing the remote access functionality. Syntax DellDisplayString Access Read-only Table 1247. Remote Access Description Info Name ...
Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Table 1252. Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26 Descripti...
Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Table 1257. Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.31 Descr...
smtpEmailEnable d(2) The remote access hardware SMTP client is enabled for sending e-mail. tftpRemoteFloppy Enabled(4) The remote access hardware TFTP client is enabled for remote floppy boot. tftpRemoteFwUpda teEnabled(8) The remote access hardware TFTP client is enabled for remote firmware update....
none(0) The dial-out destination has no state capabilities. unknownCapabilit ies(1) The dial-out destination state capabilities are unknown. enableCapable(2) The dial-out destination can be disabled or enabled. notReadyCapable( 4) The dial-out destination can be in the not ready state. dialOutPPPAut...
20 Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher availability, scalability, and management. Higher availability is achieved by using failover clusters, in which resources can automatically move between t...
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1292. Cluster Index Name clusterIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.2 Description Defines the index (one-based) of the cluster. Syntax DellObjectRange Access Read-only Table 1293. C...
Table 1297. Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.7 Description Defines the description name for the type of the cluster. Syntax DellString Access Read-only Table 1298. Cluster Name Name clusterName Object ID 1.3.6.1.4.1.674.10892.1...
21 Baseboard Management Controller Group The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides informat...
Description Defines the module name for the BMC. The module name is present only on certain systems, such as modular systems. Syntax DellString Access Read-only Table 1313. BMC IPv4 URL Name Name bmcIPv4URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.12 Description Defines the IPv4 URL for the B...
Description Defines the bit rate of the BMC serial interface. Syntax DellBMCSerialBitRateType Access Read-only Baseboard Management Controller LAN Interface Table Table 1328. BMC LAN Interface Name bmcLANInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.30 Description Defines the Baseboard Manag...
Access Read-only Table 1332. BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3 Description Defines the index (one-based) of the BMC LAN interface. Syntax DellObjectRange Access Read-only Table 1333. BMC LAN Interface State Capabilities Name bmcLANInterfa...
Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface. Syntax DisplayString (SIZE (0..32)) Access Read-only Baseboard Management Controller Group Variable Values This section includes definitions for server administrator-specific variable values used in...
22 Field Replaceable Unit Group A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system. Field Replacea...
Description Defines the serial number of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1358. FRU Part Number Name Name fruPartNumberName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.8 Description Defines the part number of the FRU Syntax DisplayString (SIZE (0..64)) Access Read-...
23 Storage Management Group The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group...
Syntax Integer Access Read-only Table 1365. Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.3 Description Identifies the manufacturer of the Storage Management software. Syntax DisplayString Access Read-only Table 1366. Software Product Name softwareProduct Objec...
Table 1369. Description Name description Object ID 1.3.6.1.4.1.674.10893.1.20.100.2 Description Provides a short description of this management software. Syntax DisplayString Access Read-only Table 1370. Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.3 Description Identifies ...
Syntax Integer Access Read-only Table 1374. Agent Time Stamp Name agentTimeStamp Object ID 1.3.6.1.4.1.674.10893.1.20.110.3 Description Identifies the last time that the agent values have been updated. Universal time in seconds since UTC 1/1/70. Syntax Integer Access Read-only Table 1375. Agent Get ...
Table 1378. Agent Hostname Name agentHostname Object ID 1.3.6.1.4.1.674.10893.1.20.110.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1379. Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.8 Description This entry...
Table 1383. Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Table 1384. Agent Global System Status ...
Access Read-only Table 1386. Agent Smart Thermal Shutdown Name agentSmartThermalShutdown Object ID 1.3.6.1.4.1.674.10893.1.20.110.15 Description Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S enclosures.Possible values:1: Enabled2: Disabled3: Not applicable Sy...
• Battery Connection Table — describes the connection between each battery on the managed system and its controller. Each controller number in the table corresponds to that controller instance in the Controller Table. Controller Table This table describes available properties for each controller on ...
Syntax DisplayString Access Read-only Table 1391. Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's (re)seller's name. Syntax DisplayString Access Read-only Table 1392. Controller Type Name controllerType Object ID 1.3.6.1....
Table 1394. Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Name controllerRebuildRateInPercent...
Access Read-only Table 1398. Controller Physical Device Count Name controllerPhysicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.11 Description Identifies the number of physical devices on the controller channel including both disks and the controller. Syntax Integer Access Read-only Ta...
Access Read-only Table 1403. Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16 Description Identifies the size of memory on the controller that is less than a megabyte. This combined with the controllerMemorySizeInMB is the total size of...
Access Read-only Table 1408. Controller C0 Port 0 ID Name controllerC0Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1409. Controller C0 Target Name controllerC0Ta...
Access Read-only Table 1413. Controller C1 Port 0 World Wide Name Name controllerC1Port0WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.26 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1414. Controller C1 Port 0...
Access Read-only Table 1418. Controller C1 Operating System Controller Name controllerC1OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1419. Controller ...
Access Read-only Table 1423. Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1424. Controller Roll-Up Stat...
Table 1426. Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 Description Durable unique ID for this controller. Syntax DisplayString Access Read-only Table 1427. Controller Alarm State Name controllerAlarmState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40...
Possible values:1: Enabled2: Disabled3: Active (enabled and active)99: Not Applicable Syntax Integer Access Read-only Table 1431. Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.44 Description The minimum firmware version for Storage Manag...
Table 1435. Controller Reconstruct Rate Name controllerReconstructRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.48 Description The rate for reconstruct on the controller. Syntax Integer Access Read-write Table 1436. Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1.3.6.1.4.1....
Table 1440. Controller Patrol Read State Name controllerPatrolReadState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.53 Description The state of the patrol read.Possible values:1: Stopped - not running2: Ready - ready to start4: Active - is running8: Aborted - has aborted Syntax Integer Access Read-...
Description Indicates encryption capability of the controller. Value: 1 - Capable, 99 - Not Applicable Syntax Integer Access Read-only Name controllerEncryptionKeyPresent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.58 Description Indicates presence of encryption key for the controller.Value: 1 - Ye...
Table 1448. Controller Spin Down Time Interval Name controllerSpinDownTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.62 Description Shows the duration in minutes after which, the unconfigured or hot spare drives is spun down to power save mode. Value: 30 to 1440 NOTE: A value of 9999 indi...
Description Indicates controller capability for automatic power saving. Value: 0 - Disabled, 1 - Enabled, 99 - Undetermined Syntax Integer Access Read-only Table 1453. Controller Configured Drives SpinUp Time Name controllerConfiguredDrivesSpinUpTime Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.67 D...
2: Failed3: Online4: Offline - The I/O has paused.6: Degraded Syntax Integer Access Read-only Table 1461. Channel Severity Name channelSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentSta...
Possible values:1: Other2: Unknown3: OK4: Non-critical5: Critical6: Non-recoverable Syntax DellStatus Access Read-only Table 1465. Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8 Description The status of the channel itself without the propagation ...
Table 1468. Channel Bus Type Name channelBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.11 Description The bus type of the channel.Possible values:1: SCSI2: IDE3: Fibre Channel4: Serial Storage Architecture (SSA)6: Universal Serial Bus (USB)7: SATA8: SAS9: PCIe Syntax Integer Access Read-only ...
Description Identifies the instance number of the enclosure entry. Syntax Integer Access Read-only Table 1472. Enclosure Name Name enclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2 Description Identifies the enclosure's name as represented in Storage Management. Syntax DisplayString Acces...
Syntax Integer Access Read-only Table 1476. Enclosure ID Name enclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6 Description Represents unique id for an enclosure. Syntax DisplayString Access Read-only Table 1477. Enclosure Processor Version Name enclosureProcessorVersion Object ID 1.3.6.1.4...
Access Read-only Table 1481. Enclosure Split Bus Part Number Name enclosureSplitBusPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.11 Description Identifies the enclosure's split bus part number. Syntax DisplayString Access Read-only Table 1482. Enclosure Product ID Name enclosureProductID O...
Access Read-only Table 1486. Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure.Possible values:1: Internal2: Dell PowerVault 200S (PowerVault 201S)3: Dell PowerVault 210S (PowerVault 211S)4: Dell PowerVault 220S (PowerVa...
Table 1489. Enclosure Channel Number Name enclosureChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.19 Description Identifies the channel number, or bus, to which the enclosure is connected. Syntax Integer Access Read-only Table 1490. Enclosure Alarm Name enclosureAlarm Object ID 1.3.6.1.4...
Possible values:1: Other2: Unknown3: OK4: Non-critical5: Critical6: Non-recoverable Syntax DellStatus Access Read-only Table 1494. Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24 Description The status of the enclosure itself without the propa...
Table 1497. Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27 Description Actual SCSI rate in the enclosure. Syntax DisplayString Access Read-only Table 1498. Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28 Descr...
Table 1502. Enclosure Total Slots Name enclosureTotalSlots Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.32 Description Shows the total number of physical slots in a storage enclosure; it includes total count of occupied and empty slots. NOTE: A value of 9999 indicates that the feature is not availab...
Table 1506. Array Disk Number Name arrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.1 Description Identifies the instance number of the array disk entry. Syntax Integer Access Read-only Table 1507. Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 Descript...
24: Rebuild25: No Media - CD-ROM or removable disk has no media.26: Formatting - In the process of formatting.28: Diagnostics - Diagnostics are running.34: Predictive Failure35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers.39: Foreign40: Clear41: Unsuppor...
Table 1513. Array Disk Revision Name arrayDiskRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.8 Description Identifies the firmware version of the array disk. Syntax DisplayString Access Read-only Table 1514. Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.2...
Table 1518. Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.13 Description The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte. Synt...
Access Read-only Table 1523. Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.18 Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte. This size plus the arrayDiskUsedSpaceInMB is the to...
8: SAS9: PCIe Syntax Integer Access Read-only Table 1527. Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare.Possible states:1: Disk is a member of a virtual disk2: Disk is a member of a disk ...
2: Unknown3: OK4: Non-critical5: Critical6: Non-recoverable Syntax DellStatus Access Read-only Table 1530. Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.25 Description Identifies the operating system device name for this disk. Syntax DisplayString Acces...
Table 1534. Array Disk Negotiated Speed Name arrayDiskNegotiatedSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.29 Description Indicates the speed at which the drive is actually running in MPS (megabytes per second). Syntax Integer Access Read-only Table 1535. Array Disk Capable Speed Name arrayD...
Description Indicates the week (1 through 53) in which this disk was manufactured. Syntax DisplayString Access Read-only Table 1539. Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 Description Indicates the four digit year in which this disk ...
Table 1543. Array Disk Alta Product Id Name arrayDiskAltaProductId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.38 Description Provides product ID for Alta interposer. Syntax Octet String Access Read-only Table 1544. Array Disk Alta Revision Id Name arrayDiskAltaRevisionId Object ID 1.3.6.1.4.1.674....
Access Read-only Table 1548. Array Disk Drive Write Cache Name arrayDiskDriveWriteCache Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.43 Description Indicates drive write cache capability for PCIe SSD devices. Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined/NotApplicable Syntax Integer Access Rea...
-1: Not Available / Not Applicable1: Drive Health Good2: Approaching Warranty Coverage Expiry3: Warranty Coverage Expired4: Approaching Read Only5: Read Only Syntax INTEGER Access Read-only Table 1553. Array Disk Read Only Name arrayDiskReadOnly Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.48 Descri...
Description Identifies the name of the enclosure as represented in Storage Management to which this array disk belongs. Syntax DisplayString Access Read-only Table 1561. Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893....
Fan Table This table describes available properties for each fan on the managed system.The following object sets up the Fan Table. Table 1573. Fan Table Name fanTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.7 Description Defines the fan table. Syntax SEQUENCE OF FanEntry Access Not accessible Table...
Description Identifies the fan's (re)seller's name. Syntax DisplayString Access Read-only Table 1578. Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 Description Identifies the current state of the fan.Possible states:0: Unknown1: Ready2: Failed3: Online4: Offline6: Degraded21...
Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1582. Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 Description This entry is obsolete. Thi...
Table 1586. Fan1 Part Number Name fan1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12 Description Identifies the part number of the fan in the enclosure. Syntax DisplayString Access Read-only Table 1587. Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.13...
4: Non-critical5: Critical6: Non-recoverable Syntax DellStatus Access Read-only Table 1590. Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for this fan. Syntax DisplayString Access Read-only Table 1591. Fan Revision Name fanRevision Object ...
Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs. Syntax Integer Access Read-only Power Supply Table Table 1599. Power Supply Table Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10892.1.600.12 Description Defines the Power Supply Table. Sy...
Description Defines the capabilities of the power supply. Syntax DellPowerSupplyStateCapabilitiesUnique ( Power Supply State Capabilities Unique ) Access Read-only Table 1604. Power Supply State Settings Unique Name powerSupplyStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.4 Descript...
Access Read-only Table 1609. Power Supply Input Voltage Name powerSupplyInputVoltage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.9 Description Defines the input voltage to the power supply in volts. Syntax DellSigned32BitRange Access Read-only Table 1610. Power Supply Power Unit Index Reference Name ...
Table 1614. Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14 Description Defines the rated input wattage of the power supply (in tenths of Watts.) Syntax DellSigned32BitRange Access Read-only Power Supply Connection Table This table des...
Description Identifies the name of the power supply in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1619. Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.3 Descr...
Temperature Probe Table Table 1623. Temperature Probe Table Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10892.1.700.20 Description Defines the Temperature Probe Table. Syntax TemperatureProbeTableEntry Access Not accessible Table 1624. Temperature Probe Table Entry Name temperatureProbeTabl...
Syntax DellStateCapabilities Access Read-only Table 1628. Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-write Table 1629. Tempe...
Syntax DellString Access Read-only Table 1633. Temperature Probe Upper Nonrecoverable Threshold Name temperatureProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.9 Description Defines the value of the temperature probe’s upper nonrecoverable threshold. Syntax DellSigned32B...
Access Read-only Table 1638. Temperature Probe Lower Nonrecoverable Threshold Name temperatureProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.14 Description Defines the value of the temperature probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Re...
Syntax DisplayString Access Read-only Table 1647. Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this temperature probe ...
Table 1651. Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.2 Description Identifies the enclosure management module's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1652. Enclosure Management M...
Table 1655. Enclosure Management Module Part Number Name enclosureManagementModulePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.6 Description Identifies the part number of the enclosure memory module. Syntax Display String Access Read-only Table 1656. Enclosure Management Module Type Name...
Possible values:1: Other2: Unknown3: OK4: Non-critical5: Critical6: Non-recoverable Syntax DellStatus Access Read-only Table 1660. Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.11 Description The status of the...
Enclosure Management Module Connection Table This table describes the connection between each enclosure management module on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table.The following object sets up the Enclosu...
Table 1667. Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnectionEMMNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.3 Description Identifies the instance number in the enclosureManagementModuleTable of the enclosure memory module in this connection. Syntax I...
Table 1677. Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.6 Description Defines the reading of the battery. Syntax DellBatteryReading ( Battery Reading ) Access Read-only Table 1678. Battery Location Name Name batteryLocationName Object ID 1.3.6.1.4.1.674.10892.1.600...
Description Identifies the instance number of the battery connection entry. Syntax Integer Access Read-only Table 1682. Battery Connection Battery Name Name batteryConnectionBatteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.2 Description Identifies the name of the battery in this connection ...
The following object sets up the Tape Drive Table. Table 1686. Tape Drive Table Name tapeDriveTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.17 Description A table of listed Tape Drives The number of entries is related to number of Tape Drives discovered in the system. The maximum number of entries ...
Syntax DisplayString Access Read-only Table 1691. Tape Drive Product ID Name tapeDriveProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.4 Description The model number of the tape drive. Syntax DisplayString Access Read-only Table 1692. Tape Drive Nexus ID Name tapeDriveNexusID Object ID 1.3.6....
Syntax INTEGER Access Read-only Logical Devices Group The Logical Devices Management Information Base (MIB) group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other.This group and all of its associated tables and objec...
Syntax INTEGER Access Read-only Table 1699. Virtual Disk Name Name virtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.2 Description Identifies the virtual disk's label generated by Storage Management or entered by the user. Syntax DisplayString Access Read-only Table 1700. Virtual Device D...
54: Degraded Redundancy Syntax INTEGER Access Read-only Table 1702. Virtual Disk Severity Name virtualDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax I...
Table 1706. Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1707. Virtual Disk ...
Table 1709. Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12 Description Indicates whether the controller's cache is used when reading from or writing to a virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not Applicable S...
Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1714. Virtual Disk Target ID Name virtualDiskTargetID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.17 Description Unique ID for the virtual disk...
Description The status of the virtual disk itself without the propagation of any contained component status.Possible values:1: Other2: Unknown3: OK4: Non-critical5: Critical6: Non-recoverable Syntax DellStatus Access Read-only Table 1718. Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1.3.6...
Table 1721. Virtual Disk Encrypted Name virtualDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.24 Description Indicates if virtual disk is encrypted.Value: 0 - No, 1 - Yes, 99 - Unknown Syntax INTEGER Access Read-only Table 1722. Virtual Disk is CacheCade Name virtualDiskIsCacheCade Objec...
Description A table of managed virtual disk partitions. The number of entries is related to number of partitions discovered in the system. The maximum number of entries is implementation dependent. NOTE: The properties in this table may not be applicable to all entries. Syntax SEQUENCE OF VirtualDis...
Access Read-only Table 1730. Virtual Disk Partition Size Name virtualDiskPartitionSize Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.4 Description Size of the partition in GB. Syntax INTEGER Access Read-only Table 1731. Virtual Disk Partition Fluid Cache Status Name virtualDiskPartitionFluidCacheStat...
Description An entry in the Fluid Cache table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax FluidCacheEntry Access Not-Accessible Table 1735. Fluid Cache Number Name fluidCacheNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.1 Description Ins...
Syntax OCTET STRING Access Read-only Table 1740. Fluid Cache License Duration Name fluidCacheLicenseDuration Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.6 Description Indicates the duration of the license validity. Syntax OCTET STRING Access Read-Only Table 1741. Fluid Cache License Capacity Name f...
Description Indicates the unique ID of the fluid cache component. Syntax OCTET STRING Access Read-only Fluid Cache Disk Table 1751. Fluid Cache Disk Table Name fluidCacheDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.5 Syntax SEQUENCE OF FluidCacheDiskEntry Access Not-Accessible Table 1752. Flui...
Access Read-only Table 1756. Fluid Cache Disk Backend Device Type Name fluidCacheDiskBackendDeviceType Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.4 Description This displays the type of the backend device beneath the fluid cache disk.Values are as below773 denotes VirtualDisk791 denotes Partition ...
Description Configured Mode of the FluidCache. The values are : • 0 - Writeback mode • 1 - Writethrough mode • 2 - PassThrough mode Syntax INTEGER Access Read-Only Table 1761. Fluid Cache Disk Nexus Name fluidCacheDiskNexus Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.9 Description Durable Unique ID...
Syntax FluidCachePoolEntry Access Not-Accessible Table 1765. Fluid Cache Pool Number Name fluidCacheDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.1 Description Instance number of the fluid cache pool entry. Syntax INTEGER Access Read-only Table 1766. Fluid Cache Pool Store Count Name fluid...
Table 1770. Fluid Cache Pool High Availability State Name fluidCachePoolHighAvailabilityState Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.6 Description Indicates if the fluid cache pool is operating in high availability mode. Syntax OCTET STRING Access Read-Only Table 1771. Fluid Cache Pool Nexus N...
Access Read-only Table 1779. Array Disk Logical Connection Virtual Disk Number Name arrayDiskLogicalConnectionVirtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.5 Description Identifies the instance number of the virtual disk to which this array disk belongs. Syntax Integer Access Read-o...
Table 1783. Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.2 Description Storage Management event message text describing the alert. Syntax DisplayString Access Read-only Table 1784. Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.3 Descri...
Table 1788. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Current status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Table 1789. Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.2...
24 Change Management Group The Change Management Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. NOTE: On systems running Linux, the optional srvadmin-cm RPM pack...
Device Group Table The following object sets up the Device Group Table. Table 1793. Device Table Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table. Syntax SEQUENCE OF DeviceEntry Access Not accessible Table 1794. Device Entry Name deviceEntry Object ID 1.3.6.1...
Table 1798. Device Vendor ID Name deviceVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.4 Description Defines the ID for the vendor supplying the device. Syntax Octet String Access Read-only Table 1799. Device ID Name deviceDeviceID Object ID 1.3.6.1.4.1.674.10899.1.5.1.5 Description Defines the ID f...
Description Identifies the version of the application. Syntax DisplayString Access Read-only Table 1808. Application Display String Name aplicationDisplayString Object ID 1.3.6.1.4.1.674.10899.1.6.1.5 Description A user visible display string that describes the application. Syntax DisplayString Acce...
25 Dell Remote Access Controller Out-of-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB attributes ...
Access Read-only Table 1814. DRsProductVersion Name drsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only Table 1815. DRsChassisServiceTag Name drsChassisServiceTag Object ID 1.3.6.1.4....
Description Defines the data center locator of the chassis. Syntax DellString Access Read-only Table 1825. DRsProductChassisAisle Name drsProductChassisAisle Object ID 1.3.6.1.4.1.674.10892.2.1.1.16 Description Defines the aisle locator of the chassis. Syntax DellString Access Read-only Table 1826. ...
Table 1830. DRsProductChassisSystemID Name drsProductChassisSystemID Object ID 1.3.6.1.4.1.674.10892.2.1.1.21 Description Defines the system ID of the chassis. Syntax INTEGER Access Read-only Table 1831. DRsFirmwareVersion Name drsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description D...
Table 1835. DRsGlobalCurrStatus Name drsGlobalCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.1 Description Defines the overall chassis status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1836. DRsIOMCurrStatus Name drsIOMCurrStatus Object ID 1.3.6.1.4.1....
Table 1840. DRsFanCurrStatus Name drsFanCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.6 Description Defines the fan subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1841. DRsBladeCurrStatus Name drsBladeCurrStatus Object ID 1.3.6.1.4...
Table 1845. DRsCMAmbientTemperature Name drsCMCAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.11 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis management card. Syntax DellTemperatureReading Access Read-only Table 1846. DRsCMProcessorTemperature Na...
Table 1850. DRsRedPrevStatus Name drsRedPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.4 Description Defines the previous redundancy status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 1851. DRsPowerPrevStatus Name drsPowerPrevStatus Object ID 1.3.6.1.4.1.674.1...
Description Defines the timestamp of the most recent power health status change. Syntax TimeTicks Access Read-only Table 1861. DRsFanChangeTime Name drsFanChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.6 Description Defines the timestamp of the most recent fan health status change. Syntax TimeTick...
Description Defines the CMC power table. Syntax SEQUENCE OF DrsCMCPowerTableEntry Access Not-accessible Table 1866. DRsCMC Power Table Entry Name drsCMCPowerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.1.1 Description Defines the CMC power table entry. Syntax DrsCMCPowerTableEntry Access Not-acces...
Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only Table 1871. DRsIdlePower Name drsIdlePower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3 Description De...
Syntax DellTimestamp Access Read-only Table 1876. DRsWattsPeakUsage Name drsWattsPeakUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.8 Description Defines the chassis peak power usage (in watts) since last reset. Syntax DellPowerReading Access Read-only Table 1877. DRsWattsPeakTime Name drsWattsPeakTi...
Table 1881. DRsWattsReading Name drsWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13 Description Defines the instantaneous chassis power usage (in watts). Syntax DellPowerReading Access Read-only Table 1882. DRsAmpsReading Name drsAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14 Descrip...
Table 1886. DRsPSUMonitoringCapable Name drsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.4 Description Defines the monitoring capabilities or the absence of a PSU in this location. Syntax DellCMCPSUCapable Access Read-only Table 1887. DRsPSUVoltsReading Name drsPSUVoltsReading Object...
Table 1891. DRsCMCServerTableEntry Name drsCMCServerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.5.1.1 Description Defines the CMC server table entry. Syntax DrsCMCServerTableEntry Access Not-Accessible CMC Server Information The following MIB tables provide CMC server information being monitored by...
Access Read-only Table 1896. DRsServerSlotNumber Name drsServerSlotNumber Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.5 Description Defines the chassis slot number of the CMC server. Syntax DellString Access Read-only Chassis Alert The following MIB tables provide information on the chassis management c...
Access Read-only Table 1901. DrsCAMessage Name drsCAMessage Object ID 1.3.6.1.4.1.674.10892.2.20.10.5 Description Defines the CSSD message of the CMC alert. Syntax DellString Access Read-only Chassis Alert 2 Table 1902. DRsCA2MessageID Name drsCA2MessageID Object ID 1.3.6.1.4.1.674.10892.2.21.10.1 D...
Table 1905. DrsCA2AlertStatus Name drsCA2AlertStatus Object ID 1.3.6.1.4.1.674.10892.2.21.10.4 Description Defines the status of the alert. Syntax DellStatus Access Read-only Table 1906. DrsCA2FQDD Name drsCA2FQDD Object ID 1.3.6.1.4.1.674.10892.2.21.10.5 Description Defines the fully qualified devi...
Table 1910. DRsAlertCurrentStatus Name drsAlertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.4 Description Current status of object causing the alert. Syntax DellStatus Access Read-only Table 1911. DRsAlertPreviousStatus Name drsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10...
26 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has...
Syntax DisplayString Table 1920. System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.4.5000.10.8 Description Specifies fully qualified domain name of the system generating the alert. Syntax DisplayString Table 1921. Service Tag Variable Name alertServiceTag Object ID 1.3.6.1.4....
Description Line Item Explanation Possible memory module event cause: <list of causes> Specifies a list of possible causes for the memory module event, for example: Possible memory module event cause: Single bit warning error rate exceededSingle bit error logging disabled Power Supply type: &l...
RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables do...
TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1017 alertDrscSEL 80 percentFull The RAC system event log is 80% full Major Status RAC detected system event log is 80% full. All 1018 alertDrscSEL 90 percentFull The RAC system event log is 90% full Major Status RAC detected...
drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag and drsGlobalCurrStatus. The trap variables are defined in the Dell Remote Access Controller Out-of-Band Group section. System Trap Group The System Trap Group contains traps that fall under the System event category....
Table 1941. Voltage Probe Traps TrapID Description Category SubCategory Severity alert2VoltageProbeNormal 2171 Voltage sensor reading is within range. Status Events Voltage Informational alert2VoltageProbeWarning 2170 Voltage sensor has detected a warning value. Status Events Voltage Minor alert2Vol...
TrapID Description Category Subcategory Severity 4353 Storage Virtual disk failure. Error Events Virtual Disk Critical Audit Traps The Audit Trap group contains traps that fall under the Audit event category. Table 1951. Audit CMC Traps TrapID Description Category SubCategory Severity alert2CMCAudit...
Table 1954. Configuration IO Virtualization Traps TrapID Description Category SubCategory Severity alert2IOVConfigurationInformation 10747 IO virtualization configuration information. Status Events IO Virtualization Informational Table 1955. Configuration Test Traps TrapID Description Category SubCa...
27 Storage Management Alert Reference Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and log...
Table 1956. Storage Management Alert Severity Alert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation. Warnin...
Trap Variables The Storage Management SNMP traps use a set of variables that are included with every trap. Below mentioned variables are the Traditional Varbinds: Table 1957. Message ID Event Name messageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.1 Description Storage Management alert (event) ...
Syntax DisplayString Access Read-only Table 1962. Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Table 1963. Current Status Event Name currentStatusEvent Object ...
Description Hostname of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 1967. Enhanced Service Tag Event Name serviceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.11 Description Service Tag of object causing the alert if applicable. Syntax DisplayString Access...
28 iDRAC7 MIB The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 7 (iDRAC7). This MIB provides management data that allows you to monitor devices and software on a system via an out...
SNMP Operations Supported SNMP version GET, GETNEXT, GETBULK SNMP v1 , v2c and v3 TRAP SNMP v1 and SNMP v2c NOTE: iDRAC7 does not support the SNMP SET operation for any data NOTE: As of iDRAC7 firmware release r1.30.30, iDRAC7 supports SNMP query operations (GET, GETNEXT, GETBULK) via the SNMPv3 pro...
Description This attribute defines the product name of a remote access card. Syntax StringType Access Read-only Table 1970. RAC Name Name racShortName Object ID 1.3.6.1.4.1.674.10892.5.1.1.2.0 Description This attribute defines the short product name of a remote access card. Syntax StringType Access...
Table 1975. RAC Type Name racType Object ID 1.3.6.1.4.1.674.10892.5.1.1.7.0 Description This attribute defines the type of a remote access card. Syntax RacTypeEnum Access Read-only Table 1976. RAC Firmware Version Name racFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.8.0 Description This att...
Description This attribute defines the service tag of the system. Syntax StringType Access Read-only Table 1980. System Express Service Code Name systemExpressServiceCode Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. Syntax Strin...
Description This attribute defines the system ID of the system. Syntax Unsigned16BitRange Access Read-only Table 1991. System OS Version Name systemOSVersion Object ID 1.3.6.1.4.1.674.10892.5.1.3.14.0 Description This attribute defines the version of the operating system that the host is running. Sy...
Table 1995. Global System Status Name globalSystemStatus Object ID 1.3.6.1.4.1.674.10892.5.2.1.0 Description This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only Table 1996. System LCD Sta...
NOTE: See the iDRAC7 MIB file for details of the tables supported under the Storage Details Group. iDRAC7 Traps The iDRAC7 generates events that result in Simple Network Management Protocol (SNMP) traps and/or entries in the iDRAC7 Lifecycle Log. This section describes the traps, also known as alert...
the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes. Syntax StringType Table 2007. Alert Chassis Service Tag Variable Name alertChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.9.0 Description For blade systems, the service tag ...
Storage Trap Group The Storage Trap Group contains traps that fall under the Storage event category of iDRAC7. Storage traps are traps generated in response to events related to the external storage subsystem of the system in which iDRAC7 resides. Table 2036. Battery Traps TrapID Description Categor...
Table 2043. Temperature Probe Traps TrapID Description Category SubCategory Severity Storage Temperature Probe Information 4211 Temperature probe information. Storage Temperature Informational Storage Temperature Probe Warning 4210 Temperature probe warning. Storage Temperature Minor Storage Tempera...
Table 2046. iDRAC IP Address Change Trap TrapID Description Category SubCategory Severity iDRAC IP Address Change 8499 iDRAC IP address has changed. Audit DRAC IP Address Informational Table 2047. License Traps TrapID Description Category SubCategory Severity License Information 8515 License informa...
29 Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib , dcs3rmt.mib and dcs3fru.mib files. Server ...
unknownCapabilities(1) The object’s capabilities are unknown. enableCapable(2) The object can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The object is not ready. enableAndNotReadyCapable (6) Enable and not ready capable. Table 2051. Dell State S...
ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical. critical(5) The object’s status is critical (failure). nonRecoverable(6) The object’s status is nonrecoverable (dead). Table 2054. Dell Status Redundancy Variable Name: DellStatusRedundancy Data Type: Intege...
The DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent back by this subagent has the most significant byte of the information as the first byte. For example, the hex address 0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ....
30 SNMP Sample Output This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of t...
Dell Manuals
-
Dell 04YJJ6A00
User Manual
-
Dell 04YJJ6A00
Manual
-
Dell 10 Pro
User Manual
-
Dell 10
Manual
-
Dell 1000
User Manual
-
Dell 1000
Manual
-
Dell 1014
User Manual
-
Dell 1000W
User Manual
-
Dell 1000W
Manual
-
Dell 0JH552A01
User Manual
-
Dell 10g
User Manual
-
Dell 1100
User Manual
-
Dell 1100
Manual
-
Dell 11
User Manual
-
Dell 11
Manual
-
Dell 11 Pro
User Manual
-
Dell 110T
User Manual
-
Dell 110T DLT1 Drive
User Manual
-
Dell 1100 Laser Mono Printer
User Manual
-
Dell 1100MP
User Manual