Page 3 - Contents; About this Guide
Contents | 3 Contents 1 About this Guide Information Symbols and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 The S2410 System Physic...
Page 4 - Technical Support
4 | Contents www.dell.com | support.dell.com Chassis Physical Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Environmental Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Power Supply . . . ....
Page 5 - SFTOSTM; Information Symbols and Warnings; describes symbols contained in this guide.
About this Guide | 5 1 About this Guide This guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting, inserting optional modules, and connecting to a power source, for the S2410 system, including the S2410CP and S2410P. After you have completed th...
Page 6 - Related Publications; SFTOS Configuration Guide,; MIBs; : Files for all SNMP MIBs supported by SFTOS; Security; : PDF files of the slide shows used in training
6 | About this Guide www.dell.com | support.dell.com Related Publications For more information about the S2410, refer to the following documents: • SFTOS Configuration Guide, Version 2.4.1 • SFTOS Command Reference, Version 2.4.1 • S2410 Quick Reference • S-Series and SFTOS Version 2.4.1 Release Not...
Page 7 - Physical Interfaces; and the; Required Equipment; The following items are necessary to install the S2410 system:
The S2410 System | 7 2 The S2410 System This chapter contains these sections: • Physical Interfaces • Required Equipment on page 7 • Features on page 8 • Ports on page 8 • System Status on page 9 Physical Interfaces The Dell Force10 S2410 is a Layer 2 switch that is available in two models — the S24...
Page 8 - Accessing the Console Port on page 23; Features; Ports
8 | The S2410 System www.dell.com | support.dell.com • At least one cable (included) to connect the power source to the S2410 AC power supply • Brackets and screws (included) for front-mounted rack installation (#2 Phillips screwdriver required but not included) • Console port: Rollover cable (RJ-45...
Page 9 - System Status; SFTOS Command Reference; LED Displays
The S2410 System | 9 System Status S2410 status data can be derived in several ways, including physical LED displays, discussed next, along with boot menu options, CLI show commands, SNMP traps, and the SFTOS Web User Interface. For details on those options, see the S2410 Quick Reference, the SFTOS ...
Page 11 - Site Preparation; For detailed S2410 specifications, refer to; Site Selection; Away from sources of severe electromagnetic noise.; Cabinet Placement; The cabinet must meet the following criteria:
Site Preparation | 11 3 Site Preparation This chapter describes requirements and site setup procedures for your S2410 system. This chapter covers the following topics: • Site Selection • Cabinet Placement on page 11 • Rack Mounting on page 12 • Fans and Airflow on page 12 • Power on page 12 • Storin...
Page 12 - Rack Mounting; Rack or Cabinet Installation on page 15; Fans and Airflow; Environmental; Power; Storing Components
12 | Site Preparation www.dell.com | support.dell.com Rack Mounting Ensure that your equipment rack is earth ground. The equipment rack must be grounded to the same ground point used by the power service in your area. The ground path must be permanent. For rack-mounting instructions, see Rack or Cab...
Page 13 - Tools Required
Site Preparation | 13 • Storage temperature should remain constant ranging from -4° to 158° F (-20°C to 70° C). • Storage humidity range should be between 10 to 95% relative humidity, non-condensing • Store on a dry surface or floor, away from direct sunlight, heat, and air conditioning ducts. • Sto...
Page 15 - Then see; Tabletop Installation; Position the S2410 so that there is proper side ventilation (see; Rack or Cabinet Installation; The S2410 provides three rack-mounting methods:; Attaching the Rack Ears
Installing the S2410 | 15 4 Installing the S2410 S2410 systems have no stacking or other optional modules, so, to install the S2410 system, you can simply install the system on a tabletop, in a rack, or in a cabinet, turn it on, and then connect ports. The following options are discussed in this cha...
Page 16 - The lower right corner of; Two-Post Rack Mounting; Site Preparation, on page 11
16 | Installing the S2410 www.dell.com | support.dell.com The lower right corner of Figure 4-1 shows the positioning of the rack ears and screws. Note that the rack ears supplied with the S2410 have a hole in the middle to accommodate the vent in the S2410. Figure 4-1. Attaching Rack Ears to Switch ...
Page 17 - Four-Post Rack-mounting with Threaded Rails; Attach the rack ears first, using only the supplied screws (see
Installing the S2410 | 17 Figure 4-2. S2410 Two-post (Front-mounted) Rack-mounting Four-Post Rack-mounting with Threaded Rails Ensure that there is adequate clearance surrounding the cabinet or rack to permit access and airflow. If you are installing two S2410 systems side-by-side, position the two ...
Page 21 - Supplying Power; Where Do I Go from Here?; Ethernet Management port
Installing the S2410 | 21 Supplying Power NOTE: The power supply cord is used as the main disconnect device; ensure that the socket-outlet is located/ installed near the equipment and is easily accessible. Both S2410 models (S2410CP and S2410P) provide built-in dual AC power supplies. Only one power...
Page 23 - Accessing Ports; This chapter contains the following sections:; Accessing the Console Port; Accessing the Ethernet Management Port on page 24
Accessing Ports | 23 5 Accessing Ports This chapter contains the following sections: • Accessing the Console Port • Accessing the Ethernet Management Port on page 24 • Accessing CX4 Ports on page 24 • Accessing XFP Ports on page 25 Accessing the Console Port You must first connect the console port t...
Page 24 - SFTOS Configuration Guide; Accessing the Ethernet Management Port; Accessing CX4 Ports; Active; Required CX4 Cable Housing
24 | Accessing Ports www.dell.com | support.dell.com See the Getting Started chapter of the SFTOS Configuration Guide for other console port details, such as setting the console timeout. Accessing the Ethernet Management Port In addition to the management VLAN that is standard on all S-Series switch...
Page 25 - Required CX4 Cable Housing Clearances; Accessing XFP Ports; ) that you insert into the port and into which you; into an XFP port, follow the procedure below:
Accessing Ports | 25 Required CX4 Cable Housing Clearances The maximum back shell dimensions of an acceptable CX4 connector are shown in Figure 5-2 . Use of a CX4 connector that exceeds those dimensions can cause damage to the S2410CP connectors and possible failure of the interface. Figure 5-2. CX4...
Page 28 - Power Supply; Agency Compliance
28 | S2410 Specifications www.dell.com | support.dell.com Power Supply NOTE: S2410 switches contain a lithium clock battery that is not user-serviceable. The switch contains no user-serviceable parts. For details on recycling the switch or any of its components, see Product Recycling and Disposal on...
Page 29 - Safety Standards and Compliance Agency Certifications
S2410 Specifications | 29 European Community Contact Dell Force10, EMEA - CentralDahlienweg 1966265 HeusweilerGermany http://www.force10networks.com/german/ Tel: +49 172 6802630 Email: EMEA Central Sales Japan: VCCI Compliance for Class A Equipment This is Class A product based on the standard of th...
Page 30 - Product Recycling and Disposal; reclaimed upon end of life per this Directive.
30 | S2410 Specifications www.dell.com | support.dell.com Electromagnetic Compatibility (EMC) Emissions • Australia/New Zealand: AS/NZS CISPR 22: 2006, Class A • Canada: ICES-003, Issue-4, Class A • Europe: EN55022 2006 (CISPR 22: 2006), Class A • Japan: VCCI V3/ 2007.04 Class A • USA: FCC CFR47 Par...
Page 31 - To remove the lithium closed-cell clock battery:
S2410 Specifications | 31 In accordance with the European WEEE Directive, electrical and electronic equipment (EEE) is to be collected separately and to be reused, recycled, or recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the WEEE Directive, as shown above, must not d...
Page 32 - Perchlorate Material; — Special handling may apply.
32 | S2410 Specifications www.dell.com | support.dell.com Batteries or packaging for batteries are labeled in accordance with European Directive 2006/66/EC concerning batteries and accumulators and waste batteries and accumulators. The Directive determines the framework for the return and recycling ...
Page 33 - The iSupport Website; Service Request
Technical Support | 33 7 Technical Support This appendix contains these major sections: • The iSupport Website • Contacting the Technical Assistance Center on page 34 • Locating Serial Numbers on page 34 • Requesting a Hardware Replacement on page 35 The iSupport Website The iSupport website provide...
Page 34 - Contacting the Technical Assistance Center; or; commands in the CLI to access the serial number.
34 | Technical Support www.dell.com | support.dell.com Contacting the Technical Assistance Center Locating Serial Numbers The serial number of the chassis is located on a sticker on the lower left front of the chassis. The serial number is below the assembly number bar code and has 11 digits. You ca...
Page 35 - Requesting a Hardware Replacement; To request replacement hardware, follow these steps:
Technical Support | 35 Requesting a Hardware Replacement To request replacement hardware, follow these steps: Step Task 1 Determine the part number and serial number of the component. To list the numbers for all components installed in the chassis, use the show hardware command. 2 Request a Return M...
Page 37 - Index
Index | 37 Index A acoustic noise 27 Agency Compliance 28 alarm LED 12 alternative management interfaces 23 altitude, maximum 27 B back-pressure support 8 battery removal 31 battery, lithium 28 baud rate 23 brackets, mounting 8 C Cabinet placement 11 cable, console 8 cable, rollover 23 Caution 5 cha...